DRAFT VERSION NOT FOR RELEASE Ethernet Switch User Manual
ESUL6-FL2_inst_ anual-Rev 1009
Copyright © KBC Networks Ltd. Page 8 of 20 www.kbcnetworks.co
2.3 Installation Method
2.3.1 DIN Rail Mount
• Re ove all packaging aterial.
• Attach the device to a DIN rail.
• Attach copper and/or fiber cables as required.
• Insert the ale power block (attached to the supplied in-line PSU) to the
fe ale power socket on the device and tighten the ter inal locking
screws using the flathead screw driver provided.
See Section 2.8 for LED status.
2.3.2 Wall-mount
• Re ove all packaging aterial.
• Unscrew the DIN rail ounting plate fro the switch taking special care
to retain the 2 screws using a Phillips No.1 or No.2 screwdriver.
• Attach the supplied wall ount plate to the switch using the 2 screws that
have just been re oved fro the DIN rail ounting plate with a Phillips
No.1 or No.2 screwdriver.
• Position the unit on the required, flat surface and secure with screws via
the ounting plate holes. Screws are not provided.
• Attach copper and/or fiber cables as required.
• Insert the ale power block (attached to the supplied in-line PSU) to the
fe ale power socket on the device and tighten the ter inal locking
screws using the flathead screw driver provided.
See Section 2.8 for LED status.
2.4 Ethernet RJ45 Connections
The ESUL6-FL2 offers 6, 10/100 Base T/TX RJ45 ports. Each port is adaptive and
supports auto MDI/MDI-X connection. They can be connected by straight through or
cross-over cables to ter inal devices, servers, hubs or other switches. Each switch
supports IEEE802.3x so the opti u trans ission ode (either half-duplex or full-
duplex) and data rate (either 10Mbps or 100Mbps) will be selected auto atically.
The connected devices should support this feature too however, if the connected
devices are not adaptive the port will send at the correct rate but with default ode
of half duplex.