KBC WES2HT Series User manual

WES2HT
Wireless Ethernet System; High Throughput
WES2HT Series
User Manual

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 1 of 142 www.kbcnetworks.com
About This Users’ Guide
Intended Audience
This manual is intended for people who want to configure any of the WES2HT Series. You
will need a basic knowledge of TCP/IP and wireless topology.
Related Documentation
Quick Start Guide
The Quick Start Guide is designed to help you get up and running. It contains basic
information on setting up your individual WES2HT unit.
Technical Specification
The Technical specification is designed to provide you with all the technical specifications
related to the WES2HT units.
KBC Networks’ Website
Please refer to www.kbcnetworks.com for additional support documentation and product
certifications.
Feedback
We welcome all comments, questions and suggestions relating to our User Guides.
Please contact us on:
Technical Department
KBC Networks Ltd
25691 Atlantic Ocean Drive
Suite B3
Lake Forest
CA 92630
Email: techsupport@kbcnetworks.com
Thank you

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 2 of 142 www.kbcnetworks.com
Document Conventions
Warnings and Notes
These are how warnings and notes are shown is this Guide.
!Warning!
Warnings tell you about things that could harm you or your device.
Note:
Notes tell you other important information or recommendations.
Example:
Examples are provided to help make the WES2HT set up straight forward.
Syntax Conventions
The WES2HT units may be referred to as the ‘device’, the ‘unit’, the ‘product’, the ‘radios’,
the ‘antenna’ or the ‘system’ in this guide.
<ENTER> denotes enter or return on your keyboard.
<*****> denotes that you need to select that option.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 3 of 142 www.kbcnetworks.com
Safety Warnings
!Warning! For your safety please read the following warning notices and instructions.
Safety, Approvals and Regulatory Domain
Information
Safety Instruction
For your protection, please read and observe all safety instructions before operating this
system and keep this sheet and any additional instructions for future reference.
Installation and Use
OBSERVE WARNINGS: All warnings in the operating instructions should be carefully
followed. Do not make any modifications to the WES2HT unit, Power Injection Module
(PIM), or any other KBC Networks electronic device, as the unit(s) will no longer comply
with legal regulations and therefore void its warranty.
WATER AND MOISTURE: The WES2HT unit is weatherproof provided it is installed in
accordance to the mounting details listed in section 5 below. However, further protection
or housing is suggested for harsh environments, as moisture damage voids its warranty.
The PIMs used in this system are NOT weatherproof. None of the modules in this system
are waterproof and should never be submerged. Severe electrical shock, personal injury
or damage to the equipment may result.
POWER SOURCE: Connect the equipment to a power source only of the type described
on the operating instructions or as marked on the equipment. Excessive or insufficient
current or voltage can cause extended trouble-shooting or even damage that could
negate its warranty. The power supply cable should not be modified/extended due to the
ability to use up to 100m of power over Ethernet cable. In addition, Ethernet cable
running from the PIM to the WEM should be kept separated from high-voltage cables
and/or transformers.
ATTACHMENTS: Use only KBC Networks’ supplied or recommended Power Injection
Modules, Power Supplies, Cat5 Cables and weather seals and plugs.
WHEN NOT IN USE: Unplug the power if the equipment is left unattended or unused
for long periods of time or during lightning storms.
REPLACEMENT PARTS: When replacement parts are required, use only replacement
parts specified by KBC Networks. Unauthorized substitutions may result in damage to
the system and could void the warranty.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 4 of 142 www.kbcnetworks.com
FCC Required Information
Radio Frequency Interference Statement for Class B Digital Devices
This equipment has been tested and found to comply with the limits for an intentional
radiator, pursuant to Part 15, subpart C of the FCC Rules. This equipment generates,
uses and can radiate radio frequency energy. This equipment generates, uses, and can
radiate radio frequency energy. If not installed and used in accordance with the
instructions, it may cause harmful interference to radio communications. The limits are
designed to provide reasonable protection against such interference in residential
situations. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause interference to radio or television reception,
which can be determined by turning the equipment on and off, the user is encouraged to
try to correct the interference but on or more of the following measures:
Re-orientate or relocate the receiving antenna of the affected radio or television.
Increase the separation between the equipment and the affected rec e i v e r.
Connect the equipment and the affected receiver to power outlets on separate
circuits.
Consult the dealer or an experienced radio/TV technician for assistance.
Shielded cables must be used with this unit to ensure compliance with Class B FCC
limits. Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
Changes or modifications not expressly approved by KBC could void the user’s authority
to operate the equipment.
FCC Power Output Restrictions
The FCC does not require licensing to implement this device. License-free operation in
the industrial, scientific and medical band is documented in FCC Rules Part 15.247. It is
the responsibility of the individuals designing and implementing the radio system to
ensure compliance with any pertinent FCC Rules and Regulations. This device must be
professionally installed.
Exposure to Radio Frequency Fields
The WES2HT is designed to operate on the 5 GHz frequency band with up to 50 Watts
EIRP maximum transmit power. This level of RF energy is above the Maximum
Permissible Exposure (MPE) levels specified in FCC OET65:97-01. The following
precautions must be taken during installation of this equipment:
The installed antenna must not be located in a manner that allows exposure of
the general population to the direct beam path of the antenna at a distance less
than 20cm. Installation on towers, masts, or rooftops not accessible to the
general population is recommended or alternatively mount the antenna in a
manner that prevents any personnel from entering the area within 20cm from the
front of the antenna.
It is recommended that the installer place radio frequency hazard warnings signs
on the barrier that prevents access to the antenna.
During installation and alignment of the antenna, do not stand in front of the
antenna assembly.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 5 of 142 www.kbcnetworks.com
During installation and alignment of the antenna, do not handle or touch the front
of the antenna.
These simple precautions must be taken to prevent general population and installation
personnel from exposure to RF energy in excess of specified MPE levels.
Industry Canada Restrictions
IC ID# 7849A-N523ESD
This Class A digital apparatus complies with Canadian ICES-003. To reduce potential
radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (E.I.R.P.) is not more than that permitted for
successful communication. This device complies with Industry Canada license-exempt
RSS standard(s).
Operation is subject to the following two conditions:
This device may not cause interference, and
This device must accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour
réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain
doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne
dépasse pas ce qui est nécessaire
pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie
Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux
conditions suivantes:
17 Compliance
Cet appareil ne peut pas provoquer d’interférences et
Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement du dispositif.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a separation distance
of at least 37.2 cm from all persons and must not be located or operating in conjunction
with any other antenna or transmitter.
Les antennes utilisées pour ce transmetteur doivent être installé en considérant une
distance de séparation de toute personnes d'au moins 37.2 cm et ne doivent pas être
localisé ou utilisé en conflit avec tout autre antenne ou transmetteur.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 6 of 142 www.kbcnetworks.com
CE Regulatory Statement
Class B ITE:
This is a Class B product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Declaration of Conformity:
KBC declares the following:
Product Name: WES2HT
Model No.: 802.11n Station conforms to the following Product Standards:
This device complies with the Electromagnetic Compatibility Directive (89/336/EEC)
issued by the Commission of the European Community. Compliance with this directive
implies conformity to the following European Norms (in brackets are the equivalent
international standards.)
Electromagnetic Interference (Conduction and Radiation): EN 55022 (CISPR 22)
Electromagnetic Immunity: EN 55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11)
Low Voltage Directive: EN 60 950: 1992+A1: 1993+A2: 1993+A3: 1995+A4:
1996+A11: 1997.
CE Mark: following the provisions of the EC directive.
KBC also declares that:
The wireless card in this product complies with the R&TTE Directive (1999/5/EC) issued
by the Commission of the European Community. Compliance with this directive implies
conformity to the following:
EMC Standards: CE: EN 300 328-2, EN 300 826 (EN 301 489-17) EN 301 893.
CE marking on this product represents the product is in compliance with all directives
that are applicable to it.
This equipment may be operated in the following countries:
Great Britain and Northern Ireland, Austria, Belgium, Denmark, Finland, France,
Germany, Ireland, Italy, Netherlands, Norway, Portugal, Romania, Switzerland, Sweden
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility
to make sure the device is operated within local country regulatory requirements.
Dynamic Frequency Selection (DFS) & Transmit Power Control (TPC):
DFS and TPC are requirements of the ETSI standard EN301 893 V1.5.1, the European
Union’s harmonized radio standard for unlicensed devices operating in the 5150 –5350
MHz and 5470 –5725 MHz frequency bands. Radar detection is required when operating
on channels whose nominal bandwidth falls partly or completely within the frequency
ranges 5250 MHz to 5350 MHz or 5470 MHz to 5725 MHz. In addition devices using the
5600 –5650 MHz band are subject to a 10 minute Channel Availability Check (CAC).
The following table shows how this can affect connection times for certain frequencies:

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 7 of 142 www.kbcnetworks.com
Frequency (MHz)
Channel Bandwidth
5MHz
10MHz
20MHz
20/40MHz
5500
2 mins
2 mins
2 mins
2 mins
5505
2 mins
5510
2 mins
2 mins
5515
2 mins
5520
2 mins
2 mins
2 mins
5525
2 mins
5530
2 mins
2 mins
5535
2 mins
5540
2 mins
2 mins
2 mins
2 mins
5545
2 mins
5550
2 mins
2 mins
5555
2 mins
5560
2 mins
2 mins
2 mins
5565
2 mins
5570
2 mins
2 mins
5575
2 mins
5580
2 mins
2 mins
2 mins
10 mins
5585
2 mins
5590
2 mins
2 mins
5595
2 mins
5600
10 mins
10 mins
10 mins
5605
10 mins
5610
10 mins
10 mins
5615
10 mins
5620
10 mins
10 mins
10 mins
10 mins
5625
10 mins
5630
10 mins
10 mins
5635
10 mins
5640
10 mins
10 mins
10 mins
5645
10 mins
5650
10 mins
10 mins
5655
2 mins
5660
2 mins
2 mins
2 mins
2 mins
5665
2 mins
5670
2 mins
2 mins
5675
2 mins
5680
2 mins
2 mins
2 mins
5685
2 mins
5690
2 mins
2 mins
5695
2 mins

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 8 of 142 www.kbcnetworks.com
5700
2 mins
2 mins
2 mins
Environmental Restrictions of Wireless Devices
KBC products are engineered to the highest standards and designed to work in a variety
of wireless applications and environments. A wireless environment includes the site in
which the product is installed, the installation including power and cabling as well as any
extra materials that might be necessary to complete the wireless project. Due to the fact
that environments and installations differ from site to site, KBC cannot control the
variables required to ensure an ideal environment. Therefore, it is not possible to
guarantee a successful application based on a drawing, application note, distance
calculation, quote or other type of material that KBC may provide. Should a quote,
drawing, etc. be made available, it is based on the performance of the WES2HT product
in an ideal environment with clear line-of-sight, absence of radio frequency (RF)
interference and/or frequency multi-path reflection. Therefore, KBC cannot be held
responsible should the products not operate as desired or should additional products be
required to complete a project. In addition, should a particular environment restrict the
usage of the WES2HT in any way, KBC offers a thirty (30) day return policy from date of
shipment to the original purchaser if goods are returned in an ‘as new’ condition.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 9 of 142 www.kbcnetworks.com
RoHS/WEEE Compliance Statement
European Directive 2002/96/EC requires that the equipment bearing this symbol on the
product and/or its packaging must not be disposed of with unsorted municipal waste.
The symbol indicates that this product should be disposed of separately from regular
household waste streams. It is your responsibility to dispose of this and other electric
and electronic equipment via designated collection facilities appointed by the
government or local authorities. Correct disposal and recycling will help prevent potential
negative consequences to the environment and human health. For more detailed
information about the disposal of your old equipment, please contact your local
authorities, waste disposal service, or the shop where you purchased the product.
Instruction of Disassembly
Note: disassembling or opening of the WES2HT unit voids warranty.
Instruction of Disassembly of KBC Product (For EU Directive 2002/95/EEC-
WEEE)
Tools required:
No. 1 Phillips screwdriver
No. 2 Phillips screwdriver
Steps for disassembly:
Remove Serial Label adhesive
Remove cover screws attaching top cover to radio module cavity.
Remove tightening screws for printed circuit board (PCB).
Take out all PCBs.
Note: When a product reaches the end of its life –return to KBC.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 10 of 142 www.kbcnetworks.com
General Public License Statement
You may have received from KBC Networks products that contained –in part –free
software (software licensed in a way that ensures your freedom to run, copy, distribute,
study, change and improve the software). Such products include the WES2HT Series of
products.
As part of these products, KBC Networks may have distributed to you hardware and/or
software that contained a version of free software programs developed by the Free
Software Foundation, a separate not-for-profit organization without any affiliation to KBC
Networks. See http://www.gnu.org/philosophy/free-sw.html for more details. If KBC
Networks distributed any portions of these free software programs to you, you were
granted a license to that software under the terms of either the GNU General Public
License or GNU Lesser General Public License (“License”, copies of which are available
from http://www.gnu.org/licenses/licenses.html). The Licenses allow you to freely copy,
modify and redistribute that software without any other statement or documentation
from us.
For at least one (1) year from the date of distribution of the applicable product or
software, KBC Networks will provide to anyone who contacts us at the contact
information provided below, for a charge of no more than our cost of physically
performing source code distribution, a complete machine-readable copy of the complete
corresponding source code for the free software programs used in the version of the
programs that we distribute to you. The cost will be free if the delivery medium of the
machine-readable copy is through the Internet.
Contact information:
Email: techsupport@kbcnetworks.com
Tel: 949.297.4930
Address: 25691 Atlantic Ocean Drive Lake Forest, CA 92630
We do ask for your understanding regarding expected delivery timelines:
We will reply within 7 working days once the request has been made through
email/telephone.
The default version sent will be the latest that we used in the firmware/programs.
Note: it may take longer if an older version is requested. The waiting time will not
exceed 2 weeks.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 11 of 142 www.kbcnetworks.com
TABLE OF CONTENTS
ABOUT THIS USERS GUIDE…………………………………………………………………………………………1
Intended Audience…………………………………………………………………………………………………………………………..….…….…1
Related Documentation…………………………………………………………………………………………………………………..……………1
DOCUMENT CONVENTIONS……………………………………………………………………………………….2
Warnings and Notes………………………………………………………………………………………………………………………...………….2
Syntax Conventions ……………………………………………………………………………………………………………………………………..2
SAFETY WARNINGS……………………………………………………………………………………………………3
SAFETY, APPPROVALS AND REGULATORY DOMAIN INFORMATION………………………….3
Safety Instruction………………………………………………………………………………………………………………………….…………….3
FCC Required Information……………………………………………………………………………………………….…………………………..4
Industry Canada Restrictions……………………………………………………………………………………………………….……………...5
CE Regulatory Statement…………………………………………………………………………………………………….………………………6
Environmental Restrictions of Wireless Devices…………………………………………………………………….…………………….8
ROHS/WEEE COMPLIANCE STATEMENT…………………………………………………………………….9
Instructions of Disassembly……………………………………………………………………………………………………..…………………..9
GENERAL PUBLIC LICENSE STATEMENT………………………………………………………………….10
1 OVERVIEW…..………………………………………………………………….……………………………14
1.1 Introduction………………………………………………………………………………………………………………………………………14
1.2 General Technical Specification…………………………………………………………………………..…………………………….15
2TYPICAL CONFIGURATIONS…………………………………………………….……………..…..17
2.1 Point-to-point…………………………………………………………………………………………………………………………………….17
2.2 Point-to-multipoint…………………………………………………………………………………………………………………………….18
2.3 Relay………………………………………………………………………………………………………………………………………………….19
2.4 Wi-Fi Access Point………………………………………………………………………………………………………………………………19
2.5 Mixed systems –WES2HT & MESH2HT (or MESHII) ….………………………………………………………………….…...20
3ANTENNA OPTIONS……………………………………………………………………………………….21
3.1 Omni-directional antennas………………………………………………………………………………………………………………..21
3.2 Integrated directional antenna options……………………………………………………………………………………………..21
3.3 External directional patch antenna options………………………………………………………………………………………..22
4POINT-TO-POINT KITS…………………………………….……………………….………………….23
5MOUNTING INSTRUCTIONS…………………………………………………………………………..24
5.1 Pole and wall-mount for integrated directional WES2HT units……………………………………………………………24

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 12 of 142 www.kbcnetworks.com
6CONNECTIONS……………………………………………………………………………….……………..26
6.1 Physical Connections…………………..…………………………………………………….……………………………………………..26
6.2 Power Connections…………………………………………………………………………………………………………………………..27
7LED STATUS……………………………………………….………………………………………………….28
8CABLE ASSEMBLY………………………………………………………………………………………….29
8.1 Strain Relief Assembly…………………………………………………………………..……………………..……….……….……….29
8.2 Configuring the Cable………………………………………………………………………………………………………………..…….29
8.3 Disconnecting the Cable from the External LAN Port……………………………………………………………….………30
9SETTING UP A BASIC LINK…………………………………………………………………………..31
9.1 Setting up a basic point-to-point link –United States & Canada…………………………………………….………..32
9.2 Setting up a basic point-to-point link –EMEA………………………….…………………………………………….………..40
9.3 Setting up a basic point-to-point link –Australia…………………….……………………………….…………….………..54
9.4 Setting up a basic point-to-multipoint link –United States & Canada………………………………...….………..62
9.5 Setting up a basic point-to-multipoint link –EMEA………………………….……………………………………….……..71
9.6 Setting up a basic point-to-point link –Australia…………………….……………………………………….…….………..84
10 INSTALLING ON SITE…………………………………………………………………………………….91
10.1 Line-of-sight…………………………………………………………………………………………………………………….………..…...91
10.2 Spacing required when mounting WES2HT units……………………………………………………………………………..93
10.3 Cable lengths when installing WES2HT units………………………………………………………………..…….……………94
10.4 Aligning the WES2HT units……………………………………………………………………………………….………………………95
10.5 Configuring IP addresses on a site…………………………………………………………………………………………………….95
10.6 Replacing/adding a WES2HT Module from/to the existing application…………………………………………….96
11 GRAPHICAL USER INTERFACE………………………………………………………………………97
11.1 Connecting to the WES2HT GUI using a PC……………………………………………………..………………….…………..97
11.2 WES2HT Menu Options……………………………………………………………………………………………………..…….…….99
12 TROUBLESHOOTING……………………………………………………………………………………137
12.1 Visual Inspection……………………………………………………………………………………………..……………………………..137
12.2 Test Cable Connections…………………………………………………………………………………………………………………...137
12.3 GUI Tools…………………………………………………………………………………………………………………………………………137
12.4 Hard reset to defaults……………………………………………………………………………………………………………………..138
12.5 Contact KBC Technical Assistance…………………………………………………………………………………………………….139
13 WARRANTY………………………………………………………………………………………………….140

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 13 of 142 www.kbcnetworks.com
1. Overview
1.1 Introduction
This manual covers all the functions of the products that form KBC Networks’ WES2HT
Series. The WES2HT High Throughput Wireless Ethernet System is a wireless
transmission system that provides a cable less transmission path for an Ethernet
channel. They are designed for use in a wide range of operating temperatures in non-
environmentally conditioned, outdoor applications. The primary function of the system is
to replace Ethernet cables where it is not practical or cost-effective or where it is beyond
distance limitations. WES2HT has been specifically designed to transmit constant
streaming video but can also be used to send and receive standard Ethernet data
packets and in some cases, with certain WES2HT models, to operate as a WiFi Access
Point. The units can be configured as a long range point-to-point wireless bridge or as a
point-to-multipoint receiving antenna communicating to numerous transmitting
Client/Station devices. This manual covers all operations and functions of the point-to-
point and point-to-multipoint systems.
1.1.1.WES2HT
The KBC WES2HT Series is a wireless transmission system that operates in the license
free 2.4GHz & 5GHz bands and also in the 4.9GHz Public Safety band (only available in
the US). The units are available as PoE or non-PoE with a range of antennas to suit
applications. The units will support useable throughput of up to 230Mbps (400Mbps
aggregate). WES2HT requires CAT6 or above (Gigabit Ethernet Cable).

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 14 of 142 www.kbcnetworks.com
General Technical Specification
WES2HT Specification
Standards
IEEE Standards
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3x Full Duplex
IEEE 802.11a 5GHz
IEEE 802.11b 2.4GHz
IEEE 802.11g 2.4GHz
IEEE 802.11y 4.9GHz US Public Safety
IEEE 802.11n MIMO
IEEE 802.11h ETSI DFS & TPC
IEEE 802.3af
Radio
Frequency (MHz)
USA & Canada:
2412 - 2472
4940 - 4990
5745 –5825
Europe:
2412 - 2472
5500 - 5700
Frequency Operation
Auto-select
User static selectable
Dynamic Frequency Selection (ETSI DFS)
Power Output
23dBm max1
Transmit Power Control (ETSI TPC)
Channel Capacity
Selectable 5, 20 or 40MHz
Modulation
OFDM
Antennas
2dBi/5dBi (2.4GHz/4.9GHz & 5GHz)
Omni-directional
9dBi (4.9GHz & 5GHz)
Directional integrated patch
Dual polarization
Beamwidth:
Azimuth: Horizontal 65°, Vertical 65°
Elevation: Horizontal 33°, Vertical 33°
11dBi (2.4GHz)
Directional integrated patch
Dual polarization
Beamwidth
Azimuth: Horizontal 56°, Vertical 62°
Elevation: Horizontal 38°, Vertical 26°
17dBi (4.9GHz & 5GHz)
Directional integrated patch
Dual polarization
Beamwidth:
1Territory specific.
2Assumes an ideal environment with maximum signal rates & within receive
sensitivity specification.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 15 of 142 www.kbcnetworks.com
Azimuth: Horizontal 30°, Vertical 33°
Elevation: Horizontal 17°, Vertical 17°
System
Data throughput2
(max values –limited by 10/100 port)
HT5 HT20 HT40
17Mbps 130Mbps 230Mbps
Latency
< 10 mS
Power
Power input (supplied by PIM)
24Vdc, 500mA
Reverse voltage protected
Power method (non-PoE WES2HT)
Passive PoE
Power method (PoE WES2HT)
IEEE 802.3af (PD)
PoE cable spec
100m on 24AWG Cat5/5e/6/6e
Mechanical
Casing
IP66
Dimensions (Patch L x W x D)
245mm x 245mm x 76mm
9.625” x 9.625” x 3”
Weight
420g
15oz
Installation
Wall-mount or pole-mount
Environmental
Operating Temperature
-40° ~ +74°C / -40° ~ +165°F
Storage Temperature
-40° ~ +90°C / -40° ~ +194°F
Operating Humidity
5% to 95% non-condensing
Connectors
10/100/1000 Electrical
1 x RJ45
Approvals
FCC Part 15 subpart C
Class B
IC ID# 7849A-N523ESD
CE
Class B
EN 55024 (IEC61000-4-2,3,4,5,6,8,11)
Electromagnetic Immunity
EN 55022 (CISPR 22)
Electromagnetic Interference (Conduction
and Radiation)
EN 60 950: 1992+A1; 1993+A2;
1995+A4; 1996+A1; 1997
Low Voltage Directive
EN 300 328-2
EN 300 826
EN 301 489-17
EN 301 893
R&TT Directive (1999/5/EC)
2Assumes an ideal environment with maximum signal rates & within receive
sensitivity specification.

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 16 of 142 www.kbcnetworks.com
2. Typical Configurations
The WES2HT units are available to work in the following configurations:
Point-to-point
Point-to-multipoint
Relay
Wi-Fi Access Point
Mixed systems
oWESII / WES2HT
oWESII or WES2HT / MESH2HT
2.1 Point-to-Point
2.1.1 Non-PoE WES2HT
Note: The drawings above and below show the parts that come in a standard WES2HT-
KT (i.e., WES2HT Host and Client and accessories). The power supplies and power
injectors in the kit will only power the WES2HT and will not power the camera or any
other device other than the WES2HT units.
2.1.2 PoE WES2HT
Note: The system is capable of being powered by PoE or via the passive power injector
(PIM) and power supply included with the product. In essence, there is only one version
of the system but it can be powered via the PIM if there is no PoE switch available or via
an IEEE 802.3af PSE device.
WES2HT Host
WES2HT Client
WES2HT Client
WES2HT Host

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 17 of 142 www.kbcnetworks.com
2.2 Point-to-multipoint
2.1.1.Non-PoE WES2HT
2.1.2.PoE WES2HT
Note: Switches must be gigabit POE or gigabit POE+
Note: The system is capable of being powered by PoE or via the passive power injector
(PIM) and power supply included with the product. In essence, there is only one version
of the system but it can be powered via the PIM if there is no PoE switch available or via
an IEEE 802.3af PSE device.
WES2HT Client
WES2HT Host
WES2HT Client
WES2HT Client
High Megapixel Camera
WES2HT Client
WES2HT Host
WES2HT Client
WES2HT Client

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 18 of 142 www.kbcnetworks.com
Manual
-
WES2HT
-
WES2HT-WES2HT
Rev1407
-
1
2.3 Relay
2.4 Wi-Fi Access Point
Note: Only multipoint Hosts are able to operate as a Wi-Fi AP (i.e., WES2HT-AB-Ax /
WES2HT-AB-Bx or WES2HT-DB-Ax / WES2HT-DB-Bx -- “x” is a place holder for the
actual indicator used in the complete model number to identify the global type of power
supply included in the kit)
WES2HT Host # 2
WES2HT Host #1
WES2HT Client #1
WES2HT Client #2

WES2HT User Manual
Manual-WES2HT-Rev1407-1
Copyright © KBC Networks 2013 Page 19 of 142 www.kbcnetworks.com
2.5 Mixed systems –WES2HT & MESH2HT (or MESHII)
In many wireless designs there are multiple transmitters sending to one common
receiver. Often the amount of throughput coming into the transmitter is less than
99Mbps so the standard WESII series could be used on the transmit side. On the receive
side, however, the overall throughput coming into the receiver may exceed 99Mbps and
therefore need the HT multipoint host. In the drawing below, assume that the camera
icon represents numerous cameras and/or high megapixel but the total amount of
throughput at each transmit site will never exceed 99Mbps. The diagram also assumes
that the amount of throughput at the receive Host site is more than 99Mbps but less
than 230Mbps.
Note: Switch at the Host receive side must be gigabit (POE optional)
WES2HT MP Host
Table of contents
Other KBC Network Router manuals
Popular Network Router manuals by other brands

AirTurn
AirTurn PED operating manual

Teldat
Teldat M2 installation manual

D-Link
D-Link DIR-130 - Broadband VPN Router Specifications

Cisco
Cisco Universal Broadband Router uBR7200 Hardware installation guide

Juniper
Juniper J2320 Getting started guide

Enterasys
Enterasys X-Pedition XSR-3150 Getting started guide