1GENERAL........................................................................................................ 3
2BASIC SAFETY PRECAUTIONS .................................................................... 3
3TECHNICAL DATA.......................................................................................... 6
4APPLIANCE OVERVIEW................................................................................. 7
5UNPACKING, SETUP AND COMMISSIONING............................................... 8
Unpacking .............................................................................................................................................. 8
Placing.................................................................................................................................................... 8
Mains connection.................................................................................................................................. 9
6COMMISSIONING............................................................................................ 9
Turning on the ionizer........................................................................................................................... 9
Turning on the fan................................................................................................................................. 9
Applications:........................................................................................................................................ 10
7SERVICE, MAINTENANCE, DISPOSAL ....................................................... 11
Cleaning................................................................................................................................................ 11
Maintenance Service.......................................................................................................................... 11
Disposal................................................................................................................................................ 11
8DECLARATION OF CONFORMITY............................................................... 11

YBI-01A-BA-e-1620 3
1 GENERAL The ionizer has conductive peaks supplied by high
voltage which, based on corona discharge, generate
positively and negatively charged ions in the immediate
vicinity. These are attracted by the electrostatic charge of
goods to be weighed and, thus, neutralise the interfering
electrostatic charge. This also does away with the forces
falsifying the weighing (such as falsified weighing result,
weighing value drifted).
2 Basic Safety Precautions
WARNING
The use of ionizer is only intended in combination with
electronic weighing balances. Do not use for any other
purposes.
Never operate the ionizer in explosive environment. The
serial version is not explosion protected.
Protect the ionizer against high air humidity /
temperature, steams and dust;
Take care to select a location free of water and oil
Do not expose the ionizer to strong humidity for
extended periods. Non-permitted condensation
(condensation of air humidity on the appliance) may
occur if a cold appliance is taken to a considerably
warmer environment. In this case, acclimatize the
disconnected ionizer for ca. 2 hours at room
temperature.
Whilst the ionizer is switched on, do not touch the ion
source; see sticker on the left side.
In case of smoke development, smell of fire, strong
heating-up of the ionizer or when the red LED starts
glowing, turn off the ionizer immediately and disconnect
it from the mains.
If water or other foreign matter enters the ionizer, turn
off the master switch immediately and disconnect it from
the mains.

4 YBI-01A-BA-e-1620
On account of the high voltage technology, handle the
ion source and exits with care.
Do not take apart or modify the ionizer.
Prevent damage caused by dropping, vibration or shock;
see sticker on the left side.
Always use the genuine power pack. The stated voltage
value must be the same as the local voltage.
Risk of injury! The peaks of the ion source are sharp
and cutting.
The ionizer generates poisonous ozone; ensure
sufficient ventilation.
For maintenance and repair work disconnect the ionizer
from the mains.
Disconnect the ionizer from the mains during periods of
idleness.

YBI-01A-BA-e-1620 5
CAUTION
Maintain and clean the ionizer at regular intervals.
●Clean the ion source after 100 hours.
●Replace the ion source after 10 000 hours.
Starting up a damaged ionizer may result in a short
circuit, fire or electric shock.
Starting up out of doors and inside vehicles is prohibited
and will result in total loss of warranty.
The occurrence of electromagnetic fields may result in
major display deviations (incorrect weighing results).
Discharge sample at a sufficient distance from the
weighing balance.
During normal operation the green LED will be glowing,
in case of a breakdown the red LED.
If the red LED is glowing, turn off the ionizer at the
master switch and turn it on again. If the red LED
continues to glow, inform the manufacturer.
The ionizer may heat up slightly during operation.
Prior to ionising powdery goods to be weighed, turn off
the fan.
Ionisation results are better when the fan is turned on
and the period required for discharging the sample will
be shortened.

6 YBI-01A-BA-e-1620
3 Technical Data
Distance
“sample ion source“ c. 5 – 40 cm
Discharge time 9 s/5 cm, 13 s/10 cm, 100 s/40 cm
(with fan turned on)
Ozone concentration 0 ~ 0,05 ppm (2cm from ion source)
Ion source Stainlees steel
Maximum air volume 0.06 cm3/min
Weight 310 g
Dimensions [cm] 11 x 10,5 x 6
Ambient conditions 0- 50 °C, 20 – 80 % air humidity (non-condensing)
AC adapter (primary) AC 100-240V, 50 / 60Hz
Rated electric power supply DC 12V, 500 mA
Pollution Degree 2
Overvoltage Category Category II
Altitude Up to 2000 m
Installation Site device may only be used indoors

YBI-01A-BA-e-1620 7
4 Appliance overview
1. Ion source
2. LED Ionizer operation (green = normal operation, red = breakdown)
3. LED fan operation (yellow = on)
4. Fan on- and off-switch
5. Mains adapter connection
6. Fan
7. Main switch

8 YBI-01A-BA-e-1620
5 Unpacking, Setup and Commissioning
Unpacking Remove device carefully from packaging, remove plastic
wrapping and place device at the planned work place.
Scope of delivery 1. Ionizer
2. Mains adapter
3. Operating instructions
Placing
With adjustable feet
Without adjustable feet

YBI-01A-BA-e-1620 9
Mains connection Select a country-specific power plug and insert it in the
power unit.
Power is supplied via the external mains adapter. The
stated voltage value must be the same as the local
voltage.
Only use original KERN mains adapters. Using other
makes requires consent by KERN.
Turn off the ionizer (master switch “OFF“) before
connecting it to the mains adapter.
6 Commissioning
Turning on the ionizer
Set master switch to “ON“.
The green LED starts glowing.
During normal operation the green LED will be glowing, in
case of a breakdown the red LED.
If the red LED is glowing, turn off the ionizer at the master
switch and turn it on again. If the red LED continues to
glow, disconnect the device from the mains and contact
the manufacturer.
After use turn off with master switch "OFF".
Turning on the fan Ionisation results are better when the fan is turned on and
the period required for discharging the sample will be
shortened.
Information:
Turn off fan for powdery, easily whirled up samples.
Set switch of fan to “ON”.
The yellow LED starts glowing.
Ensure sufficient ventilation even when the fan is turned
on.

10 YBI-01A-BA-e-1620
Applications:
The ionizer is designed to be used in combination with
electronic weighing balances!
Discharge of solids or weighing containers.
Ionisation results are better when the fan is turned on
and the period required for discharging the sample will
be shortened.
Discharge of powdery samples. Discharge prevents
whirling up, problems with toxic samples.
Turn off fan for easily whirled up samples.
Discharge of goods to be weighed, glass wind screen or
weighing containers.
Discharge of beakers etc.
Powdery samples are deposited at the inner wall of the
glass when being poured into the beaker. This is
prevented by discharging the beaker.

YBI-01A-BA-e-1620 11
7 Service, maintenance, disposal
Cleaning
WARNING
Disconnect the device from the mains before
cleaning / change of filter.
Do not take apart the ionizer.
Do not use aggressive cleaning agents (solvents etc.)
instead clean with a soft cloth soaked in mild soap suds.
Take care that the device is not penetrated by fluids and
polish it with a dry soft cloth.
Remove loose sample residues / powder carefully with the
help of a brush or hand-held vacuum cleaner.
Keep ion source and fan clean, keep holes placed on front
part of the ionizer clean.
Maintenance
Service The appliance may only be opened by trained service
technicians who are authorized by KERN.
Before opening, disconnect from power supply.
Disposal Disposal of packaging and appliance must be carried out
by operator according to valid national or regional law of
the location where the appliance is used.
8 Declaration of conformity
To view the current EC/EU Declaration of Conformity go
to:
www.kern-sohn.com/ce
Table of contents
Popular Air Ionizer manuals by other brands

Desco
Desco Chargebuster 60640 Installation, operation and maintenance

GPS
GPS FC24-AC Start-Up Checklist

greenfan
greenfan 1600-01 Installation, operation and maintenance instructions

ITW
ITW Simco ION Installation and operating instructions

VEVOR
VEVOR EHM-959 operation instruction

GPS
GPS GPS-DM48-AC Start-Up Checklist