5. Connect the power adapter to the controller.
6. Install the 6' air tube to the pencil ionizer. Connect
the opposite end of the tube to the AIR OUT port on
the controller.
7. Install the 8' air tube to the AIR IN port on the
controller. Connect the opposite end of the tube to a
clean dry air (CDA) source.
8. Use the air tube holder to combine the air tube and
ionizer power cable for improved handling.
Holder
Figure 6. Installing an air tube holder
Operation
WARNING:
• Do not operate the main unit by turning the nozzle
toward a human body, especially to the face or to
the eye of a person. This may cause serious injury
to the person.
• Do not let the nozzle of the main unit touch
conductive or live parts.
• Always supply air when using this product. The
ozone concentration inside the ionizer would
increase due to electric discharge. This may
damage the ionizer.
• This product emits ozone. Do not use this products
in an enclosed space.
1. Turn ON the controller’s power switch.
2. Open the main valve of the clean dry air (CDA)
supply, and supply 7 to 87 psi air pressure to the
controller.
3. Operate the controller’s pressure regulator to the
desired level.
4. Use the air mode switch on the controller to select
the desired setting.
5. Hold the pencil ionizer, and point its nozzle at the
area to be neutralized. Press the trigger to emit
ionized air.
6. When shutting down the product, turn the controller
OFF, and close the air supply’s main valve.
Maintenance
WARNING: Always turn OFF the power and air to the
product before performing any maintenance. The tip of
the emitter point is sharp. Avoid contact.
Cleaning the Emitter Point
To maintain optimum neutralization efficiency and
operation, cleaning should be performed on a regular
basis. Use the Desco 60506 Emitter Point Cleaner or
a swab dampened with isopropyl alcohol to clean the
ionizer’s emitter point.
1. Shut OFF the controller and the air supply.
2. Remove the nozzle from the pencil ionizer.
3. Gently clean the emitter point using a swab
dampened with Isopropyl alcohol. Screw the nozzle
back onto the ionizer when complete.
The emitter point is a consumable part, and its
operational time is over 20,000 hours. The controller
uses a solenoid valve that is rated for 50,000,000 open/
close operations. Contact Desco customer service
should either of the parts require replacement.
Figure 7. Using the Pencil Type Ionizer