KERN HCD 60K-2 User manual

1
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-mail: info@kern-sohn.com
Phone: +49-[0]7433-9933-0
Fax: +49-[0]7433-9933-149
www.kern-sohn.com
User manual
Electronic Crane Scale
Logbook
Periodic maintenance and service
KERN HCD
Version 1.4
2022-02
GB
HCD-BA-e-2214

HCD-BA-e-2214 2
GB
KERN HCD
Rev. 1.4 2022-02
User manual / logbook
Electronic Crane Scale
Contents
1. Technical specification _____________________________________________________3
1.1 Dimensions [mm] ___________________________________________________________5
1.2 Nameplate ________________________________________________________________6
1.3 Declaration of Conformity_____________________________________________________7
2. General safety instructions __________________________________________________8
3. About the crane s c ale ____________________________________________________ 12
3.1 Remote control___________________________________________________________ 13
3.2 Stickers_________________________________________________________________ 14
4. S tart ___________________________________________________________________ 15
4.1 Unpacking ______________________________________________________________ 15
4.2 Original dimensions _______________________________________________________ 16
4.3 Rechargeable battery operation______________________________________________ 16
4.4 Battery operation _________________________________________________________ 17
4.5 Scale hanging ___________________________________________________________ 18
5. Operation ______________________________________________________________ 19
5.1 Safety instructions ________________________________________________________ 19
5.2 Crane scale loading _______________________________________________________ 20
5.3 Switching on/off __________________________________________________________ 23
5.4 Zeroing_________________________________________________________________ 23
5.5 Weighing _______________________________________________________________ 23
5.6 Weight unit switching ______________________________________________________ 24
5.7 Functions _______________________________________________________________ 24
6. Menu __________________________________________________________________ 27
7. Adjus tment _____________________________________________________________ 28
8. Maintenance, repair, cleaning and disposal __________________________________ 29
8.1 Cleaning and disposal _____________________________________________________ 29
8.2 Periodic maintenance and service____________________________________________ 30
8.3 “Periodic maintenance” checklist _____________________________________________ 32
8.4 Maintenance table ________________________________________________________ 33
8.5 Drawings of a hook, shackle and crane scale ___________________________________ 34
8.6 Inspection cycles _________________________________________________________ 35
8.7 Drawing with “h” dimension _________________________________________________ 36
9. Annex _________________________________________________________________ 37
9.1 “Extended maintenance” checklist (general inspection) ___________________________ 37
9.2 “Spare parts and repairs” checklist ___________________________________________ 38

3 HCD-BA-e-2214
1. Technical s pecification
KERN HCD 60K-2 HCD 100K-2 HCD 300K-1
Product number / type
THCD 60K-2-A
THCD 100K-2-A
THCD 300K-1-A
Interval (
d
)
0.02 kg
0.05 kg
0.1 kg
Weighing range (Max) 60 kg 150 kg 300 kg
Tare range
(subtractive) 60 kg 150 kg 300 kg
Reproducibility 0.02 kg 0.05 kg 0.1 kg
Linearity ±0,04 kg ±0,1 kg ±0,2 kg
Recommended adjustment
weight (class),
not delivered 50 kg (M1) 100 kg (M1) 200 kg
(M1)
Settling time 2 s
Accuracy 0.2% of the Max value
Heating time 10 min
Units kg, lb, N
Permissible ambient
temperature +5 to +40°C
Relative humidity From 0 to 80%, non-condensing
Batteries (standard) 4 x 1.5 V, type AA batteries
operating time – illumination on: 37 h
operating time – illumination off: 100 h
Rechargeable battery optional
Input voltage
of the device 9 V, 300 mA
Input voltage of
the power supply 100–240 VAC; 50/60 Hz
Display Digit height 28 mm
Display housing dimensions
(W × D × H)
[mm] 150 × 79 × 97
Housing material plastic
Hook material Lacquered steel
Net weight [kg] 0.85
Remote control
(series component)
wireless 1 x 3 V, type CR2025 battery

HCD-BA-e-2214 4
KERN HCD 100K-2D HCD 300K-2D
Product number / type THCD 100K-2D-A THCD 300K-2D-A
Interval (
d
)
0.02 kg/0.05 kg 0.05 kg/0.1 kg
Weighing range (Max) 60 kg/150 kg 150 kg/300 kg
Tare range
(subtractive) 60 kg/150 kg 150 kg/300 kg
Reproducibility 0.02 kg/0.05 kg 0.05 kg/0.1 kg
Linearity ±0.04 kg; 0.1 kg ±0.1 kg; 0.2 kg
Recommended adjustment
weight (class),
not delivered 100 kg (M1) 200 kg
(M1)
Settling time 2 s
Accuracy
0.2% of the
Max
value
Heating time
10 min
Units kg, lb, N
Permissible ambient
temperature +5 to +40°C
Relative humidity From 0 to 80%, non-condensing
Batteries (standard) 4 x 1.5 V, type AA batteries
operating time – illumination on: 37 h
operating time – illumination off: 100 h
Battery optional
Input voltage
of the device 9 V, 300 mA
Input voltage of
the power supply 100–240 VAC; 50/60 Hz
Display Digit height 28 mm
Display housing dimensions
(W × D × H)
[mm] 150 × 79 × 97
Housing material plastic
Hook material Lacquered steel
Net weight [kg] 0.85
Remote control
(series component)
wireless 1 x 3 V, type CR2025 battery

5 HCD-BA-e-2214
1.1 Dimensions [mm]

HCD-BA-e-2214 6
1.2 Nameplate
1 KERN logo
2 Model name
3 Weighing range [Max], interval [d]
4 Power supply parameters
5 Product number
6 Serial number
7Date of manufacture
8 Recycling symbol
9 Company address

7 HCD-BA-e-2214
1.3 Declaration of Conformity
KERN & Sohn GmbH
www.kern-sohn.com
Ziegelei 1
72336 Balingen-Frommern
Germany
+0049-[0]7433-9933-0
+0049-[0]7433-9933-149
info@kern-sohn.com
EU-Konformitätserklärung | EU Declaration of Conformity
DE Wir erklären hiermit unter alleiniger Verantwortung, dass das Produkt, auf das sich diese Erklärung bezieht, mit den
nachstehenden Richtlinien übereinstimmt.
Das Produkt erfüllt die einschlägigen Harmonisierungsrechtsvorschriften der
Union.
EN We hereby declare and assume sole responsibility for the declaration that the product complies with the directives
hereinafter. The object of thedeclaration described below is in conformitywith the relevant Union harmonisation legislation.
Modell | Model |
Typ | Type |
Seriennr. | Serial no. |
HCD 100K-2, HCD
100K-2D, HCD 300K-
1, HCD 300K-2D, HCD
60K-2
HCD
xxxxxxxxxx
CE Kennzeichnung
Mark applied
EU-Richtlinie
EU directive
Normen
Standards
2006/42/EC
(MD) EN 13155:2003+ A2:2009
2011/65/EU
(RoHS) EN 63000:2018
2014/30/EU
(EMC)
EN 61326-1:2013
EN 61326-2-2:2013
Dataum | Date |:
24 February 2022
Ort der Ausstellung:
Place of issue:
72336 Balingen,
Germany
Albert Sauter
KERN & Sohn GmbH
Signatur:
Signature:
Geschäftsführer
Managing director
Other languages available online at:
www.kern-sohn.com/ce

HCD-BA-e-2214 8
2. General safety instructions
User obligations
It is necessary to follow the national OH&S regulations as well as operating, user and
safety instructions in force in the user’s location.
Follow all the safety instructions of the crane (overhead crane) manufacturer.
Always use the scale in line with its intended use. Every use type not listed in this
user manual is deemed to be the use other than the intended one. The owner,
and not KERN & Sohn, shall be the only party liable for any property damage and
injuries resulting from such non-intended use.
KERN & Sohn shall not be held liable for any unauthorised modifications or non-
intended use of the crane scale and any resulting damage and losses.
The crane scale, the crane (overhead crane) and the hoisting equipment shall be
maintained periodically and kept in a good technical condition (see chapter 8).
The inspection result should be recorded and kept in the logbook.
Organisational measures
The device should be operated solely by trained and instructed people.
Ensure constant access to the user manual in the crane scale operation location.
The installation, startup and maintenance should always be carried out by the
trained specialists.
Always use the original spare parts.
All the repairs must be carried out solely by trained specialists. Repairs and spare
parts must be documented. (See the “Spare parts and repairs of components
important for safety” list).
All the effects should be documented (see the “Periodic maintenance” checklist in
chapter 8.3).
The load-bearing structural components must be replaced as a complete spare
part assembly. The dimensions of new structural components must be recorded
(see the “Periodic maintenance” checklist in chapter 8.3).

9 HCD-BA-e-2214
Ambient conditions
Never operate the crane scale in explosive atmospheres. The standard version is
not explosion-proof.
The crane scale should always be used in ambient conditions described in this
user manual (in particular in chapter 1 “Technical Specification”).
Do not expose the crane scale to heavy moisture. Any forbidden condensation of
the air moisture on the device may occur when a cold device is placed in a much
hotter environment. In such circumstances, leave the device not connected to the
mains for 2 hours to adapt to the ambient temperature.
Do not use the crane scale in any corrosive environment.
Protect the crane scale from high humidity of air, vapours, liquids and dust.
Avoid extreme temperatures and temperature fluctuations resulting e.g. from
direct solar radiation.
If there are any electromagnetic fields (caused e.g. by mobile phones or radio
devices), static discharge and unstable power supply, high readout deviations
(erroneous weighing results) may occur. Relocate the unit or remove the source
of interference.
Intended use
The scale you bought is intended for weighing the weighed material. It should be
deemed to be a “non-automatic one”, where the material to be weighed should be
manuallyhung on the crane (overhead crane) hook vertically, carefullyand “smoothly”.
The weight can be read after it has stabilized.
The crane scale should always be used to lift and weigh loads which move freely.
Any non-intended use brings about the injury hazard. It is prohibited e.g. to:
- Exceed the permissible rated load of the crane (overhead crane), crane
scale or any components used to hoist the load;
- Carry people;
- Pull the loads diagonally;
- Remove the loads by force, pull them out or drag them.
It is prohibited to modify or alter the crane scale or the crane (overhead crane).

HCD-BA-e-2214 10
Intended use of the rotary hook
The rotary hook enables to hang the weighed material easily and comfortably.
The hook rotation is not active once the load is suspended. The load suspended
on the crane scale must not rotate. The rotation must be effected using the rotary
hook. Generally speaking, the loaded crane scale must not rotate. (Static load
suspension and removal).
Non-intended use
Do not use the scale for dynamic weighing. If the amount of the weighed material is
reduced or increased significantly, the scale’s “stabilizing and compensating”
mechanism can result in displaying erroneous weighing results! (Example: slow
outflow of the liquid from the container suspended on the scale.) Do not subject the
scale to long-term load. It maydamage the weighing mechanism andalso components
important for safety reasons.
The scale should always be operated in line with the provided guidelines. Other
operation ranges / areas require a written consent of KERN.
Guarantee
The warranty expires:
if you fail to follow our guidelines included in the user manual;
if you fail to use the device in line with the intended use;
if you introduce any modifications or open the device;
if the device gets damaged mechanically or damaged by the utilities, liquids;
if there is any ordinary wear and tear;
if the device is not set correctly or the electrical system is not as required;
if the weighing mechanism gets overloaded.
Operation in line with the safety rules
Do not stay under suspended loads.
Always position the crane (overhead crane) to ensure the load is lifted upright.
When operating the crane (overhead crane) and crane scale, always use
personal protection equipment (hard hat, protective footwear etc.).
Testing equipment supervision
Within the quality assurance system, you must check the technical measurement
properties of the scale and possibly of the available reference weight regularly. To that
aim, the responsible user should define a relevant cycle, as well as the type and scope
of such an inspection. The information on the supervision of the testing equipment, i.e.
scales, and the required reference weights, can be found on the home page of KERN
(www.kern-sohn.com). The reference weights and scales can be calibrated fast and at
a lowcost in the KERN calibration laboratory (against the national reference) approved
by DKD (Deutsche Kalibrierdienst).

11 HCD-BA-e-2214
Checking during reception
Immediately after you have received the shipment, please check if it is free from any
visible damage. The same applies for the unpacked device.
First start
To get accurate weighing results using electronic scales, ensure the scales achieves
the appropriate operating temperature (see “Heating time”, chapter 1).
During heating, the scale must be connected to the power source (rechargeable
battery or battery).
The scale accuracy depends on the local standard gravity.
Always follow the guidelines in the “Adjustment” chapter.
For the original dimension check, see chapter 4.2.
Decommissioning and storage
Remove the crane scale from the crane (overhead crane) and remove any
hoisting equipment.
Do not store the crane scale outdoors.

HCD-BA-e-2214 12
3. About the crane scale
The crane scale is a universal and economical solution used wherever weighing
takes place overhead, e.g. in recycling, metal processing, machine engineering,
transport and logistics.
The remote control makes the operation even more comfortable.
Indication overview
kg The current weight unit is a kilogram.
lb The current weight unit is a pound.
NThe current weight unit is a newton.
It means the weighing value depending on the active setting H1–
H6.
H1–H4: “Data Hold” function
H5 Animal weighing function
H6 Peak value function
Discharged batteries
HOLD “Data Hold” function enabled

13 HCD-BA-e-2214
Keyboard overview:
Button Function description
•Switching the scale on and off
•Weight blocking (freezing)
•Weight unit switching (kg lb N)
•Zeroing
•Zeroing
3.1 Remote control
The remote control enables to operate the scale the same as it is done using the
keyboard.
•Switching the scale on and off
•Weight blocking (freezing)
•Display backlight switched on for
30 s (<blon> menu setting)
•Zeroing
•Zeroing

HCD-BA-e-2214 14
3.2 Stickers
Do not stand and pass under suspended loads.
Do not use in the construction site.
Always watch the suspended load.
(example)
Do not exceed the permissible rated load of the
crane (overhead crane), crane scale or any
components used to hoist the load on the crane
scale.
The product meets the requirements of the
German Device and Product Safety Act.

15 HCD-BA-e-2214
4. S tart
+Always follow the guidelines in chapter 2 “General
safety instructions”.
4.1 Unpacking
SAFETY
TIP
concerning breaking
protection
The delivered and unpacked crane scales must not be
returned.
The crane scale is sealed by KERN.
The shackle and the hook are sealed by means of
adhesive tape.
It cannot be removed from the packaging without
tampering with the adhesive tape seal.
+The seal must not be tampered before buying.
Figure: Seal.
Thank you for understanding.
KERN Quality Assurance Team
Always use the original packaging for the return transport.
Ensure that all the available parts are here.
•Crane scale
•Remote control
•Batteries (4 x 1.5 V, type AA batteries)
•User manual (logbook)

HCD-BA-e-2214 16
4.2 Original dimensions
Before first use, check the dimensions and note them down on the checklist.
To do it, enter the dimensions in the “Periodic maintenance” checklist as per the
drawings in chapter 8.3. For that purpose, use appropriate control measures.
4.3 Rechargeable battery operation
PLEASE NOTE!
The rechargeable battery and the charger are compatible.
Always use the power supply delivered with the scale.
Do not weigh during the loading process.
The crane scale cannot be used without the rechargeable
battery, just with the power supply.
Always replace the battery with the one of the same type or of
the type recommended by the manufacturer.
The battery is not protected against all the environmental
impacts. Exposing the battery to specific environmental
conditions may result in its fire or explosion. It may result in
serious injuries or material losses.
Protect the battery from fire and heat.
Do not allow the battery to have any contact with liquids,
chemicals or salts.
Do not expose the battery to high pressure or microwave
radiation.
Do not modify any batteries, charger and do not tamper them.
Do not use any faulty, damaged or deformed battery.
Do not connect the electrical contacts of the battery and do
not use any metal items to short circuit them.
The electrolyte may be released by the damaged battery. Any
contact of the electrolyte with the skin or eyes may irritate
them.
If you detect any odor emitted by the battery, its heating,
discoloration or deformation, disconnect it immediately from
the power supply and, whenever possible, from the scale.

17 HCD-BA-e-2214
The rechargeable battery should be charged:
Before first use, charge the rechargeable battery for 14 hours using the power cord.
The rechargeable battery operating time is ca. 30 hours with the display backlight on
and 100 hours without it.
The symbol displayed means that the battery capacity will soon run down.
When the battery is charged, the following is displayed:
If the crane scale is not used for a prolonged period of time, remove the rechargeable
battery.
4.4 Battery operation
When the batteries are low, the battery symbol is displayed. After the battery is
discharged, the battery symbol and “Lo” are displayed.
Press the ON/OFF button and replace the batteries.
Open the battery compartment, replace the batteries and close the compartment.
To save batteries, the scale is switched off automatically after 4 minutes of idleness.
The “Auto-Off” function may be disabled in the menu.
If the crane scale is not used for a prolonged period of time, remove the batteries.

HCD-BA-e-2214 18
4.5 Scale hanging
Preliminary condition
The crane (overhead crane) hook must come with a safety catch (1) preventing the
unloaded crane scale from falling.
If there is no safety catch or if it damaged, contact the crane (overhead crane)
manufacturer to obtain a hook with the required safety device.
The crane scale may be used only with a crane (overhead crane) with an
“articulated joint”.
Hang the crane scale on the lower hook of the crane (overhead crane) and close
the safety catch.
The upper lug of the crane scale must be placed in the hook saddle (2).

19 HCD-BA-e-2214
5. Operation
5.1 Safety instructions
Danger
Danger of injuries from falling
loads!
Always work exercising the utmost care and in line with
the general crane (overhead crane) operation principles.
Check all the components (hook, lug, rings, rope sling
ropes, cables, chains etc.) for excessive wear or damage.
If you find any defect of the safety catch securing the hook
or its absence, do not use the scale.
Operate the device with the appropriate speed.
Avoid any fluctuations and horizontal forces. Avoid any
impact, twisting or swaying (e.g. as a
result of slanting
suspension).
Do not use the crane scale to transport loads.
Do not stand and pass under suspended loads.
Do not use in the construction site.
Always watch the suspended load.
(example)
Do not exceed the permissible rated load of the crane
(overhead crane), crane scale or any components used
to hoist the load on the crane scale.
When weighing hazardous substances (e.g. molten mass,
radioactive materials), follow the regulations concerning
hazardous substance handling!

HCD-BA-e-2214 20
5.2 Crane scale loading
To achieve correct weighing results, follow the following instructions, see the figures
on the following page:
Always use the components for load hoisting which ensure one-point free scale
suspension.
Do not use too large hoisting equipment which does not ensure one-point
suspension.
Do not use multiple slings.
Do not pull and move the load with the loaded scale.
Do not pull the hook horizontally.
Scale loading
1. Place the crane scale hook above the load.
2. Lower the crane scale to enable load suspension on the scale hook. Once you
reach the suitable height, reduce the speed.
3. Hang the load on the hook. Ensure that the safety catch is closed. When installing
the load using rope slings, ensure that the slings are well positioned in the scale
hook saddle.
4. Raise the load slowly.
When installing the load usingrope slings, ensure the load is balanced and the rope
slings are positioned correctly.
This manual suits for next models