KERN 572-30 User manual

KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Operating instructions
Precision/ compact balances and
platform scales
KERN 572/573/KB/DS/FKB/FCB
Version 5.7
12/2009
GB
572/573/KB/DS/FKB/FCB-BA-e-0957

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
2
GB KERN 572/573/KB/DS/FKB/FCB
Version 5.7 12/2009
Operating instruction
Precision/compact balances and platform scales
Table of contents:
1MODE - MENUE .......................................................................................................3
2Technical data .........................................................................................................4
2.1 KERN 572............................................................................................................................................. 4
2.2 KERN 573............................................................................................................................................. 7
2.3 KERN KB ............................................................................................................................................. 8
2.4 KERN DS............................................................................................................................................ 12
2.5 KERN FCB ......................................................................................................................................... 17
2.6 KERN FKB ......................................................................................................................................... 19
3Fundamental information (general) .....................................................................22
3.1 Intended use...................................................................................................................................... 22
3.2 Inappropriate use ............................................................................................................................. 22
3.3 Guarantee .......................................................................................................................................... 22
3.4 Monitoring the test substances ...................................................................................................... 22
4Fundamental safety information..........................................................................23
4.1 Observe the information in the operating instructions ................................................................ 23
4.2 Staff training...................................................................................................................................... 23
5Transport and storage ..........................................................................................23
5.1 Acceptance check ............................................................................................................................ 23
5.2 Packaging.......................................................................................................................................... 23
6Unpacking, installation and commissioning ......................................................23
6.1 Place of installation, place of use................................................................................................... 23
6.2 Unpacking ......................................................................................................................................... 24
6.2.1 Installation........................................................................................................................................... 24
6.3 Mains supply ..................................................................................................................................... 24
6.4 Battery operation FKB...................................................................................................................... 24
6.5 Connecting peripheral equipment .................................................................................................. 24
6.6 Initial start-up .................................................................................................................................... 24
6.7 Adjustment ........................................................................................................................................ 25
6.8 Adjusting (go to 7.2.6)...................................................................................................................... 25
6.8.1 Adjusting for verification (KERN 573; FKB-M; KB-NM; FCB-M; DS-M) ............................................. 25
6.9 Verification ........................................................................................................................................ 26
7Operation ...............................................................................................................27
7.1 Display control panel ....................................................................................................................... 27
7.2 Operation........................................................................................................................................... 28
7.3 Display background illumination .................................................................................................... 32
7.4 Interface RS 232 C ............................................................................................................................ 32
7.5 RS 232 C Data output via interface RS 232 C ................................................................................ 33
7.5.1 There are 5 methods for the data output via RS 232 C ..................................................................... 33
7.5.2 Description of the data transfer .......................................................................................................... 33
7.5.3 Numerator........................................................................................................................................... 34
7.6 Printer ................................................................................................................................................ 34
7.7 Underfloor weighing......................................................................................................................... 34
8Maintenance, upkeep, disposal ...........................................................................35
8.1 Cleaning............................................................................................................................................. 35
8.2 Maintenance, upkeep ....................................................................................................................... 35
8.3 Disposal............................................................................................................................................. 35
9Troubleshooting....................................................................................................35
10 Declaration of conformity.....................................................................................36

572/573/KB/DS/FKB/FCB-BA-e-0957 3
1 MODE - MENUE
Important!
The modified settings - as well as the adjustment - must be stored when switching-off,
via the ON/OFF button.
Manufacture Setting:

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
4
2 Technical data
2.1 KERN 572
KERN 572-30 572-31 572-32 572-33
Readability (d) 0.001 g 0.001 g 0.001 g 0.01 g
Weighing range (max) 241 g 301 g 421 g 1610 g
Taring range (subtractive) 241 g 301 g 421 g 1610 g
Reproducibility 0.001 g 0.001 g 0.001 g 0.01g
Linearity ± 0.003 g ± 0.005 g ± 0.005 g ± 0.03 g
Smallest piece weight 0.001 g 0.001 g 0.001 g 0.01 g
Adjustment points 50/100/
200/240 g 50/100/
200/300 g 100/200/
300/400 g 0.5/1.0/
1.5/1.6 kg
Recommended adjusting
weight F1 (not supplied) 200 g 200 g +100 g 200 g + 200 g 1 kg + 500 g
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 180 x 310 x 90
Vibration filter yes
Weighing plate stainless
steel mm Ø 106 Ø 106 Ø 106 Ø 150
Units see menu
Weight kg (net) 2.3 2.3 2.3 2.3
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 5
KERN 572-35 572-37 572-39 572-43
Readability (d) 0.01 g 0.01 g 0.01 g 0.1 g
Weighing range (max) 2410 g 3010 g 4210 g 10100 g
Taring range (subtractive) 2410 g 3010 g 4210 g 10100 g
Reproducibility 0.01 g 0.01 g 0.01 g 0.1g
Linearity ± 0.03 g ± 0.05 g ± 0.05 g ± 0.3 g
Smallest piece weight 0.01 g 0.01 g 0.01 g 0.1 g
Adjustment points 0.5/1.0/
2.0/2.4 kg 1.0/1.5/
2.0/3.0 kg 1.0/2.0/
3.0/4.0 kg 2/5/10 kg
Recommended adjusting
weight F1 (not supplied) 2 kg 2 kg + 1 kg 2 kg + 2 kg 10 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 180 x 310 x 90
Vibration filter yes
Weighing plate stainless
steel mm Ø 150 Ø 150 Ø 150 160 x 200
Units see menu
Weight kg (net) 2.3 2.3 2.3 2.7
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
6
KERN 572-45 572-49 572-55 572-57
Readability (d) 0.05 g 0.1 g 0.05 g 0.1 g
Weighing range (max) 12100 g 16100 g 20100 g 24100 g
Taring range (subtractive) 12100 g 16100 g 20100 g 24100 g
Reproducibility 0.05 g 0.1 g 0.05 g 0.1g
Linearity ± 0.15 g ± 0.3 g ± 0.25 g ± 0.3 g
Smallest piece weight 0.05 g 0.1 g 0.05 g 0.1 g
Adjustment points 2/5/10/12 kg 5/10/15/16 kg 5/10/15/20 kg 5/10/15/20/24 kg
Recommended adjusting
weight F1 (not supplied) 10 kg 10 kg + 5 kg 20 kg 20 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 180 x 310 x 90
Vibration filter yes
Weighing plate stainless
steel mm 160 x 200 160 x 200 160 x 200 160 x 200
Units see menu
Weight kg (net) 2.7 2.7 2.7 2.7
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 7
2.2 KERN 573
KERN 573-34NM 573-36NM 573-46NM 573-56NM
Accuracy class II II II II
Readability (d) 0.01 g 0.01 g 0.1 g 0.1 g
Verification value (e) 0.1 g 0.1 g 1 g 1 g
Weighing range (max) 650 g 2000 g 6500 g 20000 g
Minimum load (Min) 0.5 g 0.5 g 5 g 5 g
Taring range (subtractive) 650 g 2 000 g 6500 g 20000 g
Reproducibility 0.01 g 0.01 g 0.1 g 0.1g
Linearity ± 0.03 g ± 0.03 g ± 0.3 g ± 0.3 g
Smallest piece weight 0.01 g 0.01 g 0.1 g 0.1 g
Adjustment points 200g/500g/600g 500g/1000g/
2 000g 2/5/6 kg 5/10/20 kg
Recommended adjusting
weight F1 (not supplied) 600 g / F1 2 kg / F1 5 kg / F2 20 kg / F1
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 30 °C
Housing (B x D x H) mm 180 x 310 x 90
Vibration filter yes
Weighing plate stainless
steel mm Ø 150 Ø 150 160 x 200 160 x 200
Units g, kg g, kg g, kg g, kg
Weight kg (net) 2.3 2.3 2.7 2.7
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
8
2.3 KERN KB
KERN KB 120-3N KB 200-3N KB 240-3N KB 360-3N
Readability (d) 0.001 g 0.001 g 0.001 g 0.001 g
Weighing range (max) 121 g 201 g 241 g 361 g
Taring range (subtractive) 121 g 201 g 241 g 361 g
Reproducibility 0.001 g 0.001 g 0.001 g 0.001g
Linearity ± 0.003 g ± 0.003 g ± 0.003 g ± 0.005 g
Smallest piece weight 0.001 g 0.001 g 0.001 g 0.001 g
Adjustment points 20/50/100/120 g 50/100/150/200 g 100/150/
200/240 g 100/200/
300/360 g
Recommended adjusting
weight F1 (not supplied) 100 g 200 g 200 g 200 g + 100 g
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 167 x 250 x 85
Vibration filter yes
Weighing plate stainless
steel mm Ø 81 Ø 81 Ø 81 Ø 81
Units see menu
Weight kg (net) 1 1 1 1
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 9
KERN KB 1200-2N KB 2000-2N KB 2400-2N KB 3600-2N
Readability (d) 0.01 g 0.01 g 0.01 g 0.01 g
Weighing range (max) 1 210 g 2 010 g 2 410 g 3 610 g
Taring range (subtractive) 1 210 g 2 010 g 2 410 g 3 610 g
Reproducibility 0.01 g 0.01 g 0.01 g 0.01g
Linearity ± 0.03 g ± 0.03 g ± 0.03 g ± 0.05 g
Smallest piece weight 0.01 g 0.01 g 0.01 g 0.01 g
Adjustment points 0.2/0.5/1.0/1.2 kg 0.5/1.0/1.5/2.0 kg 1.0/1.5/2.0/2.4 kg 1.0/2.0/3.0/3.6 kg
Recommended adjusting
weight F1 (not supplied) 1 000 g 2 000 g 2 000 g 2 kg + 1 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 167 x 250 x 85
Vibration filter yes
Weighing plate stainless
steel mm 130 x 130 130 x 130 130 x 130 130 x 130
Units see menu
Weight kg (net) 1.5 1.5 1.5 1.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
10
KERN KB
10000-1N
KB
10k0.05N
Accuracy class
Readability (d) 0.1 g 0.05 g
Weighing range (max) 10 100 g 10 100 g
Taring range (subtractive) 10 100 g 10 100 g
Reproducibility 0.1 g 0.05 g
Linearity 0.3 g 0.15 g
Smallest piece weight 0.1 g 0.05 g
Adjustment points 2/5/10 kg 2/5/10 kg
Recommended adjusting
weight F1 (not supplied) 10 kg 10 kg
Stabilization time (typical) 3 sec. 3 sec.
Permitted environmental tem-
perature +10 °C ... + 40 °C +10 °C ... + 40 °C
Housing (B x D x H) mm 167 x 250 x 85 167 x 250 x 85
Weighing plate stainless steel
mm 150 x 170 150 x 170
Units see menu see menu
Vibration filter yes yes
Weight kg (net) 1.7 1.7
Data interface yes (RS232) yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 11
KERN KB
650-2NM KB
6500-1NM KB
2000-2NM KB
10000-1NM
Accuracy class II II II II
Readability (d) 0.01 g 0.1 g 0.01 g 0.1 g
Verification value (e) 0.1 g 1 g 0.1 g 1 g
Weighing range (max) 650 g 6 500 g 2 000 g 10 000 g
Minimum load (Min) 0.5 g 5 g 0.5 g 5 g
Taring range (subtractive) 650 g 6 500 g 2 000 g 10 000 g
Reproducibility 0.01 g 0.1 g 0.01 g 0.1g
Linearity ± 0.03 g ± 0.3 g ± 0.03 g ± 0.3 g
Smallest piece weight 0.01 g 0.1 g 0.01 g 0.1 g
Adjustment points 200/500/600 g 2/5/6 kg 0.5/1.0/1.5/2.0 kg 2/5/10 kg
Recommended adjusting
weight F1 (not supplied) 600 g 6.0 kg 2 000 g 10 kg
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 30 °C
Housing (B x D x H) mm 167 x 250 x 85
Vibration filter yes
Weighing plate stainless
steel mm 130 x 130 150 x 170 130 x 130 150 x 170
Units g, kg, ct
Weight kg (net) 1.5 1.7 1.5 1.7
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
12
2.4 KERN DS
KERN DS
3K0.01S DS
5K0.05S DS
8K0.05 DS
10K0.1S
Readability (d) 0.01 g 0.05 g 0.05 g 0,1 g
Weighing range (max) 3 100 g 5 100 g 8 100 g 10.100 g
Taring range (subtractive) 3 100 g 5 100 g 8 100 g 10.100 g
Reproducibility 0.02 g 0.05 g 0.05 g 0.1 g
Linearity ± 0.05 g ± 0.15 g ± 0.15 g ±0.3 g
Smallest piece weight 0.01 g 0.05 g 0.05 g 0.1 g
Adjustment points 1/2/3 kg 2/5/10 kg 2/4/5/7/8 kg 2/5/10 kg
Recommended adjusting
weight F1 (not supplied) 3 kg 10 kg 5 kg + 2 kg 10 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 228 x 228 x 70 228 x 228 x 70 315 x 305 x 70 228 x 228 x 70
Vibration filter
Weighing plate stainless
steel mm 228 x 228 228 x 228 315 x 305 228 x 228
Units see menu see menu see menu see menu
Weight kg (net) 5.5 5.5 7.5 5,5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 13
KERN DS
16K0.1 DS
20K0.1 DS
30K0.1
Accuracy class
Readability (d) 0.1 g 0.1 g 0.1 g
Verification value (e)
Weighing range (max) 16 100 g 20 100 g 30 100 g
Minimum load (Min)
Taring range (subtractive) 16 100 g 20 100 g 30 100 g
Reproducibility 0.1 g 0.1 g 0.1g
Linearity ± 0.3 g ± 0.3 g ± 0.3 g
Smallest piece weight 0.1 g 0.1 g 0.1 g
Adjustment points 5/10/15/16 kg 5/10/15/20 kg 10/15/20/30 kg
Recommended adjusting
weight F1 (not supplied) 10 kg + 5 kg 20kg 20 kg + 10 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 315 x 305 x 70
Vibration filter yes
Weighing plate stainless
steel mm 315 x 305 315 x 305 315 x 305
Units see menu see menu see menu
Weight kg (net) 7.5 7.5 7.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
14
KERN DS
36K0.2 DS
30K0.1L DS
36K0.2L DS
60K0,2
Accuracy class
Readability (d) 0.2 g 0.1 g 0.2 g 0.2 g
Verification value (e)
Weighing range (max) 36 100 g 30 100 g 36 100 g 60 100 g
Minimum load (Min)
Taring range (subtractive) 36 100 g 30 100 g 36 100 g 60 100 g
Reproducibility 0.2 g 0.1 g 0.2 g 0.2g
Linearity ± 0.6 g ± 0.3 g ± 0.6 g ± 0.6 g
Smallest piece weight 0.2 g 0.1 g 0.2 g 0.2 g
Adjustment points 10/15/20/
30/36 kg 10/15/20/
30 kg 10/15/20/
30/36 kg 20/30/50/60 kg
Recommended adjusting
weight F1 (not supplied) 20 kg + 10 kg 20 kg + 10 kg 20 kg + 10 kg 50 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 315 x 305 x 70 450 x 350 x 115
Vibration filter yes
Weighing plate stainless
steel mm 315 x 305 450 x 350
Units see menu see menu see menu see menu
Weight kg (net) 7.5 9.5 9.5 9.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 15
KERN DS
65K0.5 DS
100K0.5 DS
150K1
Readability (d) 0,5 g 0,5 g 1 g
Weighing range (max) 65 100 g 101 000 g 151 000 g
Taring range (subtractive) 65 100 g 101 000 g 151 000 g
Reproducibility 0,5 g 0,5 g 1 g
Linearity ± 1,5 g ± 1,5 g ± 3 g
Smallest piece weight 0,5 g 0,5 g 1 g
Adjustment points 20/30/50/60 kg 20/50/100 kg 50/100/150 kg
Recommended adjusting
weight F1 (not supplied) 50 kg 50 kg + 50 kg 3 x 50 kg
3 x 50 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 450 x 350 x 115
Vibration filter yes
Weighing plate stainless
steel mm 450 x 350
Units see menu see menu see menu
Weight kg (net) 9.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
16
KERN DS
15K0.1M DS
65K1M DS
150K1M DS
50K1TM DS
100K2TM
Accuracy class II II II III III
Readability (d) 0.1 g 1 g 1 g 1 g / 2 g / 5 g 2 g / 5 g /10
g
Verification value (e) 1 g 10 g 10 g 1 g / 2 g / 5 g 2 g / 5 g /10
g
Weighing range (max) 15 000 g 65 000 g 150 000 g 10 kg/ 20 kg/
50 kg 20 kg/ 50 kg/
100 kg
Minimum load (Min) 5 g 50 g 50g 50 g 100 g
Taring range (subtractive) 15 000 g 65 000 g 150 000 g 50 000 g 100 000 g
Reproducibility 0.1 g 1 g 1 g 1 g 1 g
Linearity ± 0.3 g ± 2 g ± 3 g ± 2 g
Smallest piece weight 0.1 g 1 g 1 g 1 g
Adjustment points 5/10/15/kg 20/30/50/
60 kg 50/100/
150 kg 20/40/50 kg 50/100g
Recommended adjusting
weight F1 (not supplied) 10 kg + 5 kg 50 kg 3 x 50 kg 50 kg 2 x 50 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 30 °C +10 °C ... + 40 °C
Housing (B x D x H) mm 315 x 305 x 70 450 x 350 x 115
Vibration filter yes
Weighing plate stainless
steel mm 315 x 305 450 x 350
Units see menu see menu see menu see menu see menu
Weight kg (net) 7.5 9.5 9.5 9.5 9.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 17
2.5 KERN FCB
KERN FCB
6K0.02B FCB
12K0.05B FCB
12K0.1B FCB
24K0.1B FCB
24K0.2B
Readability (d) 0.02 g 0.05 g 0.1 g 0.1 g 0.2 g
Weighing range (max) 6 100 g 12 100 g 12 100 g 24 100 g 24 100 g
Taring range (subtrac-
tive) 6 100 g 12 100 g 12 100 g 24 100 g 24 100 g
Reproducibility 0.02 g 0.05 g 0.1 g 0.1 g 0.2 g
Linearity ± 0.06 g 0.15 g 0.3 g 0.3 g 0.6 g
Smallest piece weight 0.02 g 0.05 g 0.1 g 0.1 g 0.2 g
Adjustment points 2/5/6 kg 2/5/10/12 kg 2/5/10/12 kg 5/10/15/
20/24 kg 5/10/15/
20/24 kg
Recom. adjustment
weight F1
(not added) 5 kg 10 kg 10 kg 20 kg 20 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typi-
cal) 3 sec.
Permitted environ-
mental temperature + 10 °C ... + 40 °C
Vibration filter yes
Housing
(B x D x H) mm 270 x 345 x
106 270 x 345 x
106 270 x 345 x
106 270 x 345 x
106 270 x 345 x
106
Weighing plate,
stainless steel 253x228 253x228 253x228 253x228 253x228
Units see menu
Vibration filter yes
Weight kg (net) 3.3 3.3 3.3 3.3 3.3
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
18
KERN FCB
8K0.1BM FCB
15K0.1BM FCB
15K1BDM
Accuracy class II II III
Readability (d) 0.1 g 0.1 g 1 g
Verification value (e) 1 g 1 g 1 g / 2 g
Weighing range (max) 8 000 g 15 000 g 7.5 kg / 15 kg
Minimum load (Min) 5 g 5 g 50 g
Taring range (subtractive) 8 000 g 15 000 g 50 000 g
Reproducibility 0.1 g 0.1 g 1g
Linearity ± 0.2 g ± 0.3 g ±3 g
Smallest piece weight 0.1 g 0.1 g 1 g
Adjustment points 5/8 kg 5/10/15 kg 5/10/15 kg
Recommended adjusting
weight F1 (not supplied) 5 kg + 2 kg 15 kg 15 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 30 °C +10 °C ... + 40 °C
Housing (B x D x H) mm 270 x 345 x 106
Vibration filter yes
Weighing plate stainless
steel mm 253 x 228
Units g, kg
Weight kg (net) 3.3
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB-BA-e-0957 19
2.6 KERN FKB
KERN FKB
6K0.02 FKB
8K0.05 FKB
16K0.05 FKB
16K0.1
Readability (d) 0.02 g 0.05 g 0.05 g 0.1 g
Weighing range (max) 6 100 g 8 100 g 16 100 g 16 100 g
Taring range (subtractive) 6 100 g 8 100 g 16 100 g 16 100 g
Reproducibility 0.02 g 0.05 g 0.05 g 0.1g
Linearity ± 0.06 g ± 0.15 g ± 0.25 g ± 0.3 g
Smallest piece weight 0.02 g 0.05 g 0.05 g 0.1 g
Adjustment points 2/4/5/6 kg 2/4/5/7/8 kg 5/10/15/16 kg 5/10/15/16 kg
Recommended adjusting
weight F1 (not supplied) 5 kg 5 kg + 2 kg 10 kg + 5 kg 10 kg + 5 kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 350 x 390 x 120
Vibration filter yes
Weighing plate stainless
steel mm 340 x 240 340 x 240 340 x 240 340 x 240
Units see menu see menu see menu see menu
Weight kg (net) 6.5 6.5 6.5 6.5
Data interface yes (RS232)

572/573/KB/DS/FKB/FCB/PCB-BA-e-0957
20
KERN FKB
36K0.1 FKB
36K0.2 FKB
65K0.2 FKB
65K0.5
Readability (d) 0.1 g 0.2 g 0.2 g 0.5 g
Verification value (e)
Weighing range (max) 36 100 g 36 100 g 65 100 g 65 100 g
Minimum load (Min)
Taring range (subtractive) 36 100 g 36 100 g 65 100 g 65 100 g
Reproducibility 0.1 g 0.2 g 0.2 g 0. g
Linearity ± 0.5 g ± 0.6 g ± 1.0 g ± 1.5 g
Smallest piece weight 0.1 g 0.2 g 0.2 g 0.5 g
Adjustment points 10/20/30/36 kg 10/20/30/36 kg 20/30/50/60 kg 20/30/50/60 kg
Recommended adjusting
weight F1 (not supplied) 20 kg + 10 kg 20 kg + 10 kg 50kg 50kg
Humidity of air max. 80% rel. (non-condensing)
Stabilization time (typical) 3 sec.
Permitted environmental
temperature +10 °C ... + 40 °C
Housing (B x D x H) mm 350 x 390 x 120
Vibration filter yes
Weighing plate stainless
steel mm 340 x 240 340 x 240 340 x 240 340 x 240
Units see menu see menu see menu see menu
Weight kg (net) 6.5 6.5 6.5 6.5
Data interface yes (RS232)
This manual suits for next models
67
Table of contents
Other KERN Scale manuals