After installation, TEST THE UNIT’S ELECTRONICS by pressing and releasing t
test/reset button. A series of beeps
he
will sound, followed by the message ‘Fire! Fire!’
s
r being in HUSH mode, it will verbally announce
has been cleared of the condition
unit is in HUSH mode, pushing the test/reset button on
the
SH CONTROL FEATURE AND
ton will
he alert continues, the alarm will
ous condition. If the unit has detected a CO level of 100 PPM or greater,
utton will result in a voice message ‘Caution, carbon
o smoke. When
then another two series of beeps and the message ‘WARNING! CARBON
MONOXIDE!’ followed by 4 additional short beeps.
Weekly testing is required! If at any time it does not perform as described,
verify that the battery doesn’t need replacing. Clean dust and any other build-up
off the unit. If it still doesn’t operate properly call the Consumer Hotline on 0800 917
0722.
USHH Control Feature
The HUSH feature has the capability of temporarily desensitizing the smoke alarm
circuit for approximately 10 minutes. This feature is to be used only when a known
alarm condition, such as smoke from cooking, activates the alarm.
You can put your Smoke/CO Alarm in HUSH mode by pushing the test/reset button.
If the smoke is not too dense, the alarm will silence immediately, the unit will verbally
announce HUSH MODE ACTIVATED, and the green LED will flash every 2 second
for approximately 10 minutes.
This indicates that the smoke alarm is in a temporarily desensitized condition. Your
Smoke/CO Alarm will automatically reset after approximately 10 minutes. When the
unit returns to normal operation afte
HUSH MODE CANCELLED, and sound the alarm if smoke is still present. The
HUSH feature can be used repeatedly until the air
causing the alarm. While the
alarm will also end the HUSH period.
NOTE: DENSE SMOKE WILL OVERRIDE THE HU
SOUND A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTIFY THE
SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS.
Reset Feature
If the Smoke/CO Alarm is sounding a CO alarm, pressing the test/reset but
initiate a test/reset. If the CO condition that caused t
reactivate.
Alarm/Peak Level Memory
If the green LED is blinking once every 16 seconds, the unit has detected a
hazard
pushing the Test/Reset b
monoxide previously detected’
. Peak level also happens if the unit detects smoke and then comes out of alarm.
However, there is no voice message if the unit is in peak level due t
the Test/Reset button is pushed, the unit will produce three rapid beeps. Pushing the
test/reset button resets the memory.
LED Indicator Operation
Red LED
The red LED will flash in conjunction with the alarm sounder. Therefore, the red LED
will flash during a smoke alarm, a CO alarm, a low battery mode chirp and a unit
error mode chirp.