MODULARM®DL-35™
Refrigerator/Freezer Door Alarm and Monitor
INSTALLATION AND OPERATING MANUAL
TM
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 2 of 12
1-800-327-8766
NOTICE
Before you start, please read these instructions thoroughly in order to obtain maximum
benefit from the capabilities offered by the DL-35.
CONTENTS
PRODUCT OVERVIEW 03
DL-35TM OPERATION 04
OPERATION WITH IP-1 ILLUMINATED PUSHBUTTON 05
INSTALLING THE DL-35TM AND OPTIONAL IP-1 06
CONNECTING THE DL-35TM AND OPTIONAL IP-1 07
SETUP AND TEST 08
DL-35TM DIAGRAM 09
GENERAL SAFETY MEASURES AND PRODUCT LIMITATIONS 10
SPECIFICATIONS 11
CONTACT INFORMATION 12
PRODUCT OVERVIEW
Kitchen Brains®patented Modularm®DL-35™ Freezer/Cooler Door Alarm and Monitor is a reduced-feature
door monitoring system for walk-in freezer and cooler doors that saves energy, trains personnel to close
doors, increases operator safety and operational efficiency, and helps to maintain product integrity.
The DL-35 reduces coil icing, thus lowering maintenance costs and saving additional money.
The DL-35 offers the following functions:
• Visual and audible alarms when door is ajar
• Field adjustable door monitor settings
• Panic/entrapment alarm (requires optional IP-1 Push Illuminated button)
• Automatic control of interior compartment lights
• Replaces ordinary light and fan shutoff switches
• ETL listed
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 3 of 12 kitchenbrains.com
DL-35 TM OPERATION
Status of the door is monitored with provided low voltage Magnetic Contacts. Additional contacts
may be added to monitor multiple doors (A low current electromechanical switch, opening when the
door is opened may also be utilized). An internal relay inside the DL-35 provides automatic control
of compartment lights.
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 4 of 12
1-800-327-8766
MONITORED CONDITIONS
SYSTEM FUNCTION DOOR CLOSED *
(NORMAL OPERATION)
DOOR OPENED DOOR OPENED FOR
TOO LONG
(ALARM DELAY TIMES
OUT)
DOOR CLOSED
DOOR AJAR ALARM No alarm Audible alarm delay
activates
Field adjustable, 5-45
minutes. See diagram
on pg 9
Audible alarm
activates
Alarm functions reset
No alarm
INTERIOR LIGHTS OFF ON ON Lights turn off 10
minutes after door is
closed
Unless optiOnal IP-1 is
installed and pressed
*Door closed at any time always restores normal operation. (No Alarm, Lights Off.)
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 5 of 12 kitchenbrains.com
OPERATION OF THE OPTIONAL IP-1 ILLUMINATED PUSH BUTTON:
In order to increase product capabilities, the DL-35 has been designed to accept the IP-1, a low voltage,
Illuminated Pushbutton, that incorporates a piezo horn, as an additional means of device activation. The
IP1 is an optional accessory, that can be mounted inside the monitored compartment.
ADDED FUNCTIONALITY OFFERED BY THE IP-1
WITH THE DOOR OPEN:
IP-1 functions are dependent on the status of the Pushbutton Enable Jumper. (labeled “PB Jumper”: See
diagram on page 9).
If the Pushbutton Enable Jumper is not clipped (default), pressing the IP-1 with the door open, when a Door
Ajar Alarm occurs, will reset the alarm and restart the alarm delay timer. This can be done repeatedly and is
useful when a door is opened for a prolonged period of time, such as during loading or unloading.
If the Pushbutton Enable jumper is clipped, pressing the IP-1 with the door open when a Door Ajar Alarm
occurs, will not affect DL-35 operation. Therefore, when a Door Ajar Alarm occurs, the door must be closed to
terminate the alarm and restore normal operation.
WITH THE DOOR CLOSED:
Operation of the IP-1 with the door closed is not affected by the Pushbutton Enable Jumper. IP-1 functions
with the door closed are always as follows:
When the door is first closed, the horn in the IP-1 beeps on and off to draw attention to the IP-1 and the
Pushbutton Label. The Pushbutton Label instructs personnel inside the compartment to press the button in
order to keep the lights on with the door closed (Label is in English and Spanish languages).
1. If the IP-1 is not pressed within 40 seconds, the horn stops beeping and the lights turn off automatically
after 10 minutes.
2. Pressing the IP-1 with the door closed keeps interior lights on (or turns them on if they are off) and starts
the Automatic Panic Alarm timer (Timer delay is 20 minutes, non-adjustable).
3. If personnel remain in the compartment for 20 minutes with the door closed, the IP-1 horn begins to
beep again.
•. Re-pressing the button silences the horn and resets and restarts the Automatic Panic Alarm Timer.
This may be done repeatedly.
4. Automatic Panic Alarm: If the button is not re-pressed within 40 seconds after the IP-1 horn starts beeping
the horn and the LED on the DL-35 activate immediately to draw attention the walk-in. The Automatic Panic
Alarm is a safety feature that protects an individual who may have been injured or is otherwise disabled
inside the walk-in.
5. Manual Panic (Entrapment) Alarm: Pressing the IP-1 for 3 seconds (as described on the Pushbutton Label)
activates the LED and the audible alarm on the DL-35 as a safety feature for situations where personnel
may be trapped inside the walk-in.
Note: In all above, exiting the compartment and closing the door automatically restores normal operation.
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 6 of 12
1-800-327-8766
INSTALLING THE DL-35TM AND OPTIONAL IP-1
MOUNTING:
MAGNETIC CONTACTS:
1. Installation Tip: If desired, and if door configuration permits, the switch part of the Magnetic Contacts may
be mounted inside the DL-35 enclosure. This will not affect operation of the Magnetic Contacts and will
ensure a cleaner installation.
2. Magnetic Contacts: Magnetic Contacts may be mounted with adhesive backing or provided screws.
3. Mount magnet part of Contact onto edge of door, as far away from the hinged side as possible.
4. The magnet part of the Contact may also be mounted onto the edge of the unhinged side of the door,
preferably as high on the door as possible to minimize the possibility of damage.
5. Mount switch part of Contact onto door frame, directly adjacent to the magnet, positioned so that
Contacts close (make Contact) when door is closed.
6. When mounted, gap between magnet and switch should not exceed 1.25” when door is closed.
NOTE: Steel doors may reduce this operating gap. Position accordingly.
DL-35 ENCLOSURE:
1. Remove the faceplate.
2. If switch part of Magnetic Contact is not mounted inside the DL-35, the enclosure may be mounted in
any appropriate location on the front of the walk-in.
3. If switch part of Magnetic Contact is mounted inside DL-35, position the DL-35 enclosure adjacent to
the magnet mounted on the walk-in door and mount the switch on the side wall inside the enclosure,
positioned so that Contacts close when the door is completely closed.
4. A meter or resistance scale or a continuity checker is helpful in checking Magnetic Contacts for
proper operation. A temporary power cord to the DL-35 may also be used to help in positioning Contacts
as follows: When contacts are placed properly, the LED on the DL-35 will turn on when door is open and
turn off when door is closed.
IP-1 ILLUMINATED PUSHBUTTON:
1. Mount the IP-1 inside the walk-in next to the unhinged side of the door frame.
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 7 of 12 kitchenbrains.com
CONNECTING THE DL-35TM AND OPTIONAL IP-1
NOTE: All line voltage and signaling wiring connected to the DL-35 through any side wall must be enclosed
in conduit with suitable fittings for connection to the DL-35 enclosure.
LOW VOLTAGE CONNECTIONS (See the 2 Green Terminal Strips inside the unit.):
1. Strip insulation on wires by approximately ¼”.
a. Terminal Strip connections is made by pressing down on the respective actuator button with a small
screwdriver and inserting the wire into the hole below the actuator.
b. Removing screwdriver pressure will clamp the wire.
c. Do not insert wire too far, as you may clamp onto insulation.
d. Tug gently on wires to make sure connections are secure.
2. Magnetic Contacts: Connected to the Door Switch Terminal Strip.
NOTE: Multiple Contacts wired in series may be used for multi-door compartments. Any door so
connected and opened or closed will be sensed by the DL-35.
3. IP-1 Illuminated Pushbutton: The Pushbutton comes with a pre-connected, 8’ length of 4 conductor wire.
Connect to the PB switch Terminal Strip observing the color code as shown on the diagram on the back
of these instructions (Left to right: Black, White, Red & Yellow.). The color code is also printed on the
DL-35 circuit board.
NOTE: The path for this wiring, or any wiring which enters the DL-35 enclosure from within the monitored
compartment, must be sealed with silicone to keep moisture out of the DL-35.
LINE VOLTAGE CONNECTIONS (Use top knockout for access.):
Connections are typically made through ½” thin wall conduit. Provide 120VAC for DL-35 operation and
connect to black and white wires (Required current: 90mA.).
1. Connect the green screw inside the DL-35 enclosure to earth ground.
a. Control contacts for lights are dry contacts, normally open.
b. Dry Contacts function as switches and the DL-35 does not provide any power to the lights being controlled.
2. Connect accordingly as shown on the diagram on page 9 using insulated female .250” connectors sized
for the gauge of wire that you are using. It is recommended that wiring be kept short, approximately 6-8”
in length.
3. When the DL-35 is being used to operate lights, a standard light switch is no longer required, and any
existing switches should be disconnected.
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 8 of 12
1-800-327-8766
SETUP AND TEST
1. Apply power to the DL-35.
NOTE: If door is closed when powered up, interior lights will turn on for 10 minutes and then shut off.
This is a safety feature to insure that lights will turn back on if a momentary power failure, such as from
a thunderstorm, occurs while there are personnel in the compartment.
2. A 10 position Alarm Delay Adjust Dip Switch is provided for selecting the door ajar alarm delay and for
testing. Range: 5 minutes to 45 minutes in 5 minute increments, selectable on switches 1 through 9.
Switch 10 is a test switch, and when selected will cause the DL-35 to annunciate a door ajar condition in 5
seconds. The Test Switch is provided as a means of quickly verifying device operation. If a 5 second time
delay is desired for normal usage, the Test Switch may also be used as an operating mode.
3. Select the Test Switch and simulate various modes of operation to verify that the DL-35 functions
as intended in accordance with selected settings. Once testing is competed and operation is verified,
de-select the Test Switch (unless you are using it for desired operation) and select the desired door ajar
alarm delay using ONLY ONE of switches 1 through 9. Select only one switch or erroneous times will
result. A switch must be selected for proper operation. Selection or changing of a switch or clipping
the PB Enable jumper may be done with power on or off. Power outages will not affect user settings.
Changes made in user settings with the door opened will be stored in program memory when the door is
closed and will become active the next time the door is opened.
4. After adjusting and testing, mount the faceplate onto the enclosure using the provided screws. Installation
is now complete.
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 9 of 12 kitchenbrains.com
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
DL-35™DOOR MONITOR WIRING & SETUP DIAGRAM
DL-35TM DIAGRAM
AC POWER 120VAC
B W R Y
PUSHBUTTON
SWITCH
ALARM DELAY (MINUTES)
SELECT ONLY ONE ALARM
DELAY SWITCH
LIGHTS, NA
N/O
NEUTRAL
WHITE
BLACK
CLIP JUMPER
TO DISABLE
ENABLE PUSH BUTTON
5 10 15 20 25 30 35 40 45 TEST
ON
OFF
DOOR
SWITCH
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 10of 12
1-800-327-8766
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
• This product (“Product”) must be installed by a licensed electrician experienced in working in the types of environments
for which this Product is intended to be utilized; specically, commercial Cooler/Freezer coolers and freezers (“Equipment”).
• Personnel installing the Product must carefully and completely read the Operating and Installation Instructions
(“Instructions”), and instructions and specications of the Equipment manufacturers, before attempting to operate and
install the Product. Failure to comply with the Instructions, and the instructions and specications of the Equipment
manufacturers, may result in personal injury and/or property damage and may void the warranty of the Product. Retain
the Instructions for future reference.
• The Product shall only be used for the purposes described in the Instructions.
• During installation of the Product, all applicable laws, regulations and industry rules, including local electrical and safety
codes, the National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA), must be strictly followed.
Consistent therewith, follow applicable electrical codes regarding running of low voltage wiring and high voltage wiring
in separate conduits and use appropriately rated wire (insulation type, voltage rating and wire gauge) for all connections.
Supply connection wiring must be rated at least 90°C. Use copper conductors only.
• Conrm that the power source conforms to the requirements of the Product before connecting.
• Do not exceed the rated limits of the Product. Refer to the Product specications for suitability of the Product to
the application.
• The Product is not suitable for use in wet locations. Do not expose the Product to water, moisture or condensation.
In no event should the Product be exposed to environments where sudden temperature changes with high humidity may
result in the formation of condensation.
• Any openings in the walls, ceiling or oor of the Equipment for wiring or other reason must be sealed (made
airtight and watertight) with appropriate materials (e.g., silicone, caulk or foam), both on the outside and inside of the
Equipment, to prevent moisture or condensation from entering the compartment of the Equipment and forming
and accumulating on the interior walls of the compartment and the contents of the compartment, including
the Product. Failure to properly seal such openings may (i) result in damage to the Equipment and contents of the
compartment (ii) pose a safety hazard and (iii) void the warranty of the Product.
• To prevent moisture or condensation from entering or forming in the enclosure used for the Product, any openings in
this enclosure (for wiring access or other purpose) must be appropriately sealed with materials such as silicone, caulk
or foam.
• Installation of the Product should be inspected and the Product tested by qualied personnel to ensure the Product
performs safely and in accordance with the Product specications. Periodic testing of the Product should be performed
on an ongoing basis (at least quarterly) to ensure the Product continues to perform properly.
• All personnel operating, maintaining, repairing or interfacing with the Product must be instructed in the use of the Product
and provided with the Instructions, which are accessible on the Kitchen Brains website at www.kitchenbrains.com.
• WARNING: Hazard of electric shock! Power sources must be turned off or otherwise disconnected prior to installation
or servicing of the Product. Lock and tag power disconnects to prevent an unexpected application of power.
INSTALLATION, GENERAL SAFETY MEASURES AND PRODUCT LIMITATIONS
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
Page 11of 12 kitchenbrains.com
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
SPECIFICATIONS
DL-35
DIMENSIONS
4.5” L x 4.5” W x 2.3” D
POWER SUPPLY
120VAC/60Hz @ 90mA max
20mA Quiescent
Surge Protected
AMBIENT TEMPERATURE
-10ºC to 52ºC (14ºF to 126ºF)
LIGHT CONTACTS
N/O, 30A @ 120VAC or 240VAC
CABLE LENGTH
30 meters Max
FUSE
Automatic resettable
Non-replaceable
IP-1
DIMENSIONS
4.5” L x 2.75” W x 2.0” D
(Dimensions include outdoor type
single gang outlet box)
POWER SUPPLY
5-15VDC @ 20mA Max from DL-35
AMBIENT TEMPERATURE
-40ºC to 40ºC (-40ºF to 104ºF)
CABLE LENGTH
30 meters max
HUMIDITY
90% Noncondensing
MOUNTING
Outdoor, single gang outlet box
Alternate enclosure for mounting must
be UL listed enclosure, providing multiple
wire access hubs for running low voltage
MC-1 S
POWER SUPPLY
SURF: 2-5VDC @ 100mA max Metal:-
2-5VDC @ 0.5A max from DL-35
AMBIENT TEMPERATURE
-10ºC to 52ºC (14ºF to 126ºF)
CABLE LENGTH
30 meters max
ETL LISTED
CONFORMS TO
UL STD 464A
CERTIFIED TO
CAN/CSA STD C22.2 NO. 205
Save the instructions for future reference.
© 2021 Kitchen Brains I Condential Proprietary Information I Duplication Prohibited 229-40074B
24/7 Toll-Free Technical Support
In the U.S., Canada and the Caribbean
1-800-FASTRON (1-800-327-8766)
Elsewhere
1-203-377-4414
or
[email protected]
MODULARM®DL-35TM FREEZER/COOLER DOOR ALARM AND MONITOR | OPERATING MANUAL
TM
CONNECTICUT | FLORIDA | LONDON | SHANGHAI | SINGAPORE
905 Honeyspot Road, Stratford, CT 06615 |kitchenbrains.com | 203-377-4414 | 800-327-8766
Modularm®DL-35™

Popular Security System manuals by other brands

Spot Hug GPS SECURITY SYSTEM user manual

Spot Hug

Spot Hug GPS SECURITY SYSTEM user manual

Chuango CG-A11 user guide

Chuango

Chuango CG-A11 user guide

Cavius CO ALRM installation guide

Cavius

Cavius CO ALRM installation guide

2N Telekomunikace Lift1 installation manual

2N Telekomunikace

2N Telekomunikace Lift1 installation manual

Innovative Technology ICU quick start guide

Innovative Technology

Innovative Technology ICU quick start guide

Whelen Engineering Company 295HFSA5 installation guide

Whelen Engineering Company

Whelen Engineering Company 295HFSA5 installation guide

Konyks FireSafe 2 quick start

Konyks

Konyks FireSafe 2 quick start

R.W. BECKETT GENISYS 52040 installation instructions

R.W. BECKETT

R.W. BECKETT GENISYS 52040 installation instructions

Paso PAW5500-VES Series user manual

Paso

Paso PAW5500-VES Series user manual

ASENWARE AW-D316 user manual

ASENWARE

ASENWARE AW-D316 user manual

Swann DVR16-8600 Combo Specification sheet

Swann

Swann DVR16-8600 Combo Specification sheet

AEI Security & Communications SOLARGUARD SG4000 user guide

AEI Security & Communications

AEI Security & Communications SOLARGUARD SG4000 user guide

Eaton EVT-300 Driver Instructions

Eaton

Eaton EVT-300 Driver Instructions

Interlogix ATS1235 Installation sheet

Interlogix

Interlogix ATS1235 Installation sheet

ADEMCO VISTA-250BP Installation and setup guide

ADEMCO

ADEMCO VISTA-250BP Installation and setup guide

eTIGER S4 Cell + Line quick start guide

eTIGER

eTIGER S4 Cell + Line quick start guide

ThinkX TX-DSNG user guide

ThinkX

ThinkX TX-DSNG user guide

DMP Electronics 1135 installation guide

DMP Electronics

DMP Electronics 1135 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.