manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Knoll
  6. •
  7. Controllers
  8. •
  9. Knoll VC100SS User manual

Knoll VC100SS User manual

Other Knoll Controllers manuals

Knoll VC75PM User manual

Knoll

Knoll VC75PM User manual

Knoll VC220 User manual

Knoll

Knoll VC220 User manual

Knoll VS105 User manual

Knoll

Knoll VS105 User manual

Knoll VOC120 User manual

Knoll

Knoll VOC120 User manual

Knoll VC220PM User manual

Knoll

Knoll VC220PM User manual

Knoll VS105pm User manual

Knoll

Knoll VS105pm User manual

Knoll VC220PMI User manual

Knoll

Knoll VC220PMI User manual

Knoll VC220 User manual

Knoll

Knoll VC220 User manual

Knoll MR173 User manual

Knoll

Knoll MR173 User manual

Knoll VS100PM User manual

Knoll

Knoll VS100PM User manual

Knoll VC75 User manual

Knoll

Knoll VC75 User manual

Knoll MR640 User manual

Knoll

Knoll MR640 User manual

Knoll MR200 User manual

Knoll

Knoll MR200 User manual

Knoll VC100 User manual

Knoll

Knoll VC100 User manual

Knoll VS150im User manual

Knoll

Knoll VS150im User manual

Knoll VC100PM User manual

Knoll

Knoll VC100PM User manual

Knoll VC105pm User manual

Knoll

Knoll VC105pm User manual

Knoll VC220PI User manual

Knoll

Knoll VC220PI User manual

Knoll VS27 User manual

Knoll

Knoll VS27 User manual

Knoll VC100SP User manual

Knoll

Knoll VC100SP User manual

Knoll VS100 User manual

Knoll

Knoll VS100 User manual

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Congratulations for choosing the finest stereo volume
control available. To assure correct installation and to
realize the full potential of this new volume control,
please read and follow these instructions carefully.
The Knöll VC100ss silent start transformer free room
volume control has a power capacity of 100 watts RMS
per channel with 350 watt peaks for 5 seconds
permissible. Speakers can be 4-16 ohms. The VC100ss
has floating independent grounds so bridged amplifiers
can be safely used. Frequency response is DC to
500,000 Hz +/- 0.1 dB at all power levels up to 350
watts. THD and IM distortions are barely measurable.
For best results when connecting 2 or more volume
controls to one amplifier or receiver, use a Knöll
transformer free stereo interface.
INSTALLATION TIPS:
1. Follow all electrical and building code requirements
in your area.
2. The VC100ss can be installed in an electrical junction
box but it is not required. Make sure the VC100ss white
elements do not touching anything, especially plastic
vapor barriers. To obtain the full power rating, volume
control heat needs to be ventilated. When installing the
VC100ss in an electrical box, remove the bottom and
top knockouts or drill holes to let heat dissipate.
3. Never install the VC100ss in the same electrical
junction box as high voltage equipment (75+ volt)
unless an approved barrier separates high from low
voltage equipment.
4. Speaker wire can be solid or stranded. Suggested
minimum wire size is 16 gauge and 12-14 gauge for
runs longer than 30' (10m).
5. Wire both left and right speaker outputs from the
amplifier, receiver or interface to the VC100ss inputs.
6. Proper polarity is essential to achieve best speaker
sound quality with maximum output. Be careful to wire
the + or positive terminals of the amplifier, interface,
VC100ss volume control and speakers together. Never
connect left and right channel wires of the positive OR COPYRIGHT 1996-2002
ALL RIGHTS RESERVED
C
ground (-) together as amplifier damage may result.
The - or negative terminals of the amplifier, volume
control and speakers must be wired as shown in the
diagram.
7. Wire the VC100ss "SPEAKER" outputs to the
corresponding speaker terminals as indicated on the
VC100ss connector.
8. Connect the two 12VDC power supply wires to
the VC100ss as shown taking careful note of the
polarity. These power supply wires can be daisy
chained from room to room.
9. Plug the 12VDC power supply into the switched
outlet socket on the stereo amplifier or receiver. The
VC100ss will always default to the red standby
mode when the stereo is switched off. To hear sound
in a room after the stereo has been switched on,
press the small button. The led glows green and the
sound level can be adjusted by rotating the volume
control knob.
Knöll Systems
145 Tyee Drive
Point Roberts,
WA 98281
USA and CANADA WARRANTY
Knöll Systems warrants its VC100ss sold in the USA or Canada by authorized
Knöll Systems dealers to be free of defects in materials and workmanship. This
warranty extends for two years from the date of purchase by the original consumer.
Any VC100ss returned to and found to defective by Knöll Systems within the
warranty period will be repaired or replaced at Knöll Systems option, at no charge.
Knöll Systems will not be responsible for the actual cost of installation or removal
of the product, nor for any incidental or consequential damages. Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation may not apply to you. This warranty gives you specific legal rights.
You may have additional legal rights that vary from state to state.
VC100SS
All Knöll transformer free
products include patent
pending exclusive designs
VC100ss
SILENT-START
TRANSFORMER-FREE
STEREO VOLUME CONTROL
Information and
Installation Guide
TM
TM
WIRE:
Suggest minimum 16 gauge
and for runs longer than 30
feet (10m) use 14 gauge.
STEREO AMPLIFIER OR
RECEIVER OR INTERFACE
SPEAKER OUTPUTS
+ L - - R +
RL
+
--
+
4-16
OHMS
12vdc
POWER
SUPPLY
PLUG 12vdc POWER
SUPPLY INTO RECEIVER
"SWITCHED" POWER
SUPPLY SOCKET. THE
POWER SUPPLY WIRES
CAN BE DAISY CHAINED
FROM ROOM TO ROOM.
+
-
VC100SS
Warning:
Maximum amplifier power 120 watts per channel.
Higher power amplifiers may cause damage.