11. Order Codes
Viscosity-compensated flow switches model: VKM-1...
Measuring
range
L/min oil
Pressure loss
P (bar) at
rated flow*
Brass Stainless
steel Contact Connection Option
special
connect.
Flow
direction
min. max.
0.01…0.07 0.02 1.0 VKM-1101... VKM-1201...
..R0... = 1 N/O contact
..U0... = 1 changeover contact
..F0... = 1 EX N/O contact
..C0... = 1 N/O contact (cCSAus)
..D0... = 1 changeover contact
(cCSAus)
..RR... = 2 N/O contact
..UU... = 2 changeover contact
..CC... = 2 N/O contact (cCSAus)
..DD... = 2 changeover contact
(cCSAus)
..R08 = G 1/4 ..N08 = 1/4 NPT
0= without
option
B= outlet
female
thread
inlet
BVB
manifold
B = from bottom
T = from top
L = from left
R = from right
0.1...0.45 0.03 0.8
VKM-1102... VKM-1202...
0.2...1.2 0.05 1.1
VKM-1103... VKM-1203...
..R08 = G 1/4
..R15 = G 1/2 ..N08 = 1/4 NPT
..N15 = 1/2 NPT
0.5...2 0.07 1.2
VKM-1104... VKM-1204...
0.8...3.4 0.05 0.9
VKM-1105... VKM-1205...
3...9 0.05 0.8
VKM-1106... VKM-1206...
4...14 0.08 1.1
VKM-1107... VKM-1207... ..R15 = G 1/2
..R20 = G 3/4 ..N15 = 1/2 NPT
..N20 = 3/4 NPT
5...20 0.05 1.1
VKM-1108... VKM-1208...
4...40 0.1 0.4
VKM-1109... VKM-1209... ..R20 = G 3/4
..R25 = G 1 ..N20 = 3/4 NPT
..N25 = 1 NPT
5...55 0.15 1.1
VKM-1110... VKM-1210...
7...70 0.15 1.1
VKM-1111... VKM-1211...
8...80 0.15 1.1
VKM-1112... VKM-1212... ..R25= G 1 ..N25 = 1 NPT
* Pressure loss refers to water
Viscosity-compensated flow meters model: VKM-2...
Measuring
range
L/min oil
Pressure loss
P [bar] at
rated flow*
Brass Stainless
steel Contact Connection Option
special
connect.
Flow
direction
min. max.
0.01…0.07 0.02 1.0
VKM-2101... VKM-2201...
00..= without contact
..R08 = G 1/4 ..N08 = 1/4 NPT 0= without
option
B= outlet
female
thread
inlet BVB
manifold
B = from bottom
T = from top
L = from left
R = from right
0.1...0.45 0.03 0.8
VKM-2102... VKM-2202...
0.2...1.2 0.05 1.1
VKM-2103... VKM-2203... ..R08 = G 1/4
..R15 = G 1/2 ..N08 = 1/4 NPT
..N15 = 1/2 NPT
0.5...2 0.07 1.2
VKM-2104... VKM-2204...
0.8...3.4 0.05 0.9
VKM-2105... VKM-2205...
3...9 0.05 0.8
VKM-2106... VKM-2206...
4...14 0.08 1.1
VKM-2107... VKM-2207... ..R15 = G 1/2
..R20 = G 3/4 ..N15 = 1/2 NPT
..N20 = 3/4 NPT
5...20 0.05 1.1
VKM-2108... VKM-2208...
4...40 0.1 0.4
VKM-2109... VKM-2209... ..R20 = G 3/4
..R25 = G 1 ..N20 = 3/4 NPT
..N25 = 1 NPT
5...55 0.15 1.1
VKM-2110... VKM-2210...
7...70 0.15 1.1
VKM-2111... VKM-2211...
8...80 0.15 1.1
VKM-2112... VKM-2212... ..R25= G 1 ..N25 = 1 NPT
* Pressure loss refers to water
Viscosity-compensated flow meters model: VKM-3...
Measuring
range
L/min oil
Pressure loss
P [bar] at
rated flow*
Brass Stainless
steel Contact Connection Option
special
connect.
Flow
direction
min. max.
0.01…0.07 0.02 1.0
VKM-3101... VKM-3201... ...R0... = 1 N/O contact
...U0... = 1 changeover contact
...F0... = 1 EX N/O contact
...C0... = 1 N/O contact (cCSAus)
...D0... = 1 changeover contact
(cCSAus)
...RR... = 2 N/O contact
...UU... = 2 changeover contact
…CC... = 2 N/O contact (cCSAus)
...DD... = 2 changeover contact
(cCSAus)
..R08 = G 1/4 ..N08 = 1/4 NPT 0= without
option
B= outlet
female
thread
inlet
BVB
manifold
B = from bottom
T = from top
L = from left
R = from right
0.1...0.45 0.03 0.8
VKM-3102... VKM-3202...
0.2...1.2 0.05 1.1
VKM-3103... VKM-3203... ..R08 = G 1/4
..R15 = G 1/2 ..N08 = 1/4 NPT
..N15 = 1/2 NPT
0.5...2 0.07 1.2
VKM-3104... VKM-3204...
0.8...3.4 0.05 0.9
VKM-3105... VKM-3205...
3...9 0.05 0.8
VKM-3106... VKM-3206...
4...14 0.08 1.1
VKM-3107... VKM-3207... ..R15 = G 1/2
..R20 = G 3/4 ..N15 = 1/2 NPT
..N20 = 3/4 NPT
5...20 0.05 1.1
VKM-3108... VKM-3208...
4...40 0.1 0.4
VKM-3109... VKM-3209... ..R20 = G 3/4
..R25 = G 1 ..N20 = 3/4 NPT
..N25 = 1 NPT
5...55 0.15 1.1
VKM-3110... VKM-3210...
7...70 0.15 1.1
VKM-3111... VKM-3211...
8...80 0.15 1.1
VKM-3112... VKM-3212... ..R25= G 1 ..N25 = 1 NPT