KODA LM030377 Guide

CARE & USE INSTRUCTIONS
Model: LM030377
TOWER WORK LIGHT
with Power and USB Ports
TM
IMPORTANT INFORMATION.
PLEASE READ CAREFULLY AND RETAIN
FOR FUTURE REFERENCE.
For assistance with assembly, installation, parts or customer service,
please contact us:
info@kodabuilt.com
1-866-294-9244, Monday to Friday, 8am to 5pm Pacific Time
2975 Red Hill Ave., Suite 100, Costa Mesa, CA 92626, USA

2
IMPORTANT SAFETY INSTRUCTIONS:
Read this manual thoroughly before rst use and keep it in a safe place for future
reference. To reduce risk of re, electric shock, or injury to persons, please
review the following:
• Important: For indoor and dry location use only.
• Improper connection of the grounding wire can result in electric shock. Do
not modify the power cord plug provided with the product. Never remove the
grounding prong from the plug.
• Do not plug into another power strip or extension cord.
• Do not use the product if the power cord or plug is damaged. If damaged, have it
repaired by a service facility before use. If the plug does not t the outlet, have a
proper outlet installed by a qualied electrician.
• Do not abuse the power cord. Never use the power cord to carry the product or pull
the plug from an outlet. Keep the power cord away from heat, oil, sharp edges, or
moving parts.
• Do not look directly into the LEDs when operating.
• Keep away from liquids, oils, gasoline, and all chemicals.
• Keep the product out of children’s reach; it is not a toy.
• Turn off and unplug from outlet when not in use.
• Do not sit or stand on top of the work light. It is not a chair.
• Keep proper balance and footing at all times. Do not overreach the product.
• Save these instructions.
CAUTION: Risk of electric shock. Do not use in or near wet locations such as kitchens
or bathrooms.
CAUTION: Risk of electric re. Do not charge electrical devices from the power
accessory sockets while the product is in storage.
WARNING:
• LED light output is strong enough to injure human eyes. Precautions must be
taken to prevent looking directly at the LEDs.
• If the product is damaged, it shall be exclusively replaced by the manufacturer
or the service agent or qualied person in order to avoid a hazard, subject to
our Warranty (see pg.7).
• The warnings, precautions, and instructions discussed in this manual cannot
cover all possible conditions and situations that may occur. The operator must
understand that common sense and caution are factors which cannot be built
into this product, but must be supplied by the operator.
CLEANING:
When cleaning, make sure to unplug the product and allow it to cool to room
temperature. Do not open the power accessory socket covers when cleaning. The
product can be cleaned with a feather duster or a soft damp cloth. Only plug the
product back in after it has completely dried.

3
PACKAGE CONTAINS:
Please layout all parts prior to installation.
Front
Light Switch +
Dimming Control
Back
LED Panel
Cord Wrap Storage
Master On/Off Switch
with Resettable
Overload Protection
1x USB A
1x USB C
2 x 120V Power
Socket Outlets

4
PRODUCT SPECIFICATIONS:
• Input Voltage and Current: 120 Vac, 60 Hz, 11 A
• Power Outlet Output: 120 Vac, total combined 10 A, 1200 W
• USB Output: 5 Vdc, USB C + USB A total combined 3.1 A MAX
• Light Wattage: 83 W MAX
• LED Output: 9000 Lumens
• Color Temperature: 5000K
PRODUCT OVERVIEW:
9.7 IN / 24.8 CM 8.9 IN / 22.6 CM
This product is ETL/cETL Listed
22 IN / 56 CM

5
INSTRUCTIONS:
Using the Tower Work Light:
1. Plug Work Light into electrical outlet. Flip master switch to”On” position.
2. Press the top button to select your desired light panel(s) and adjust LED
brightness. See following operation:
• Short press button to select your desired light panel. Press once to light up
one panel; press twice for two panels; press three times for three panels;
and press four times to turn off all panels.
• Long press button to dim LED brightness from 100% to 10%. Release the
button to stop at the desired dimming level.
3. Stand Work Light upright or at on its side.
Using the socket outlets and USB ports:
1. Make sure your device is turned off before plugging into the USB ports /socket
outlets.
2. Plug Work Light into electrical outlet. Flip master switch to “On” position.
3. Plug your device into the socket/USB port.
4. When you nish using the device, turn it off and unplug from Work Light.
FlatStanding

6
Handles:
Carry the worklight by the handle.
Tool tray:
Store small tools, screws, parts etc.
1. Wrap the cord around the Work Light base.
2. Clamp down the cord using U-shape clips.
Cord wrap storage:
FEATURES:
12

7
Warranty:
This KODA product carries a 5-year warranty against defects in workmanship and materials
subject to the conditions and additional warranty information available at:
www.kodabuilt.com/warranty
DISCLAIMER OF WARRANTIES, INCLUDING WARRANTY OF MERCHANTABILITY AND
WARRANTY OF FITNESS FOR PARTICULAR PURPOSE: EXCEPT AS SPECIFICALLY SET FORTH
HEREIN, NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, IS MADE AS TO THE
TOWER WORK LIGHT. KODA AND/OR ITS AFFILIATES EXPRESSLY DISCLAIMS, WITHOUT
LIMITATION, ANY STATUTORY WARRANTIES AND ALL IMPLIED WARRANTIES, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TOWER WORK LIGHT
Model: LM030377
Responsible Party:
KODA
Address: 2975 Red Hill Ave., Ste. 100, Costa Mesa, CA 92626, USA
Tel: 1-866-294-9244
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Warning: Changes or modications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modications or change to this equipment. Such modications or change could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Compliance Statement:

8
or visit us online at www.KodaBuilt.com
A Horizon Brands Company
2975 Red Hill Ave., Ste. 100, Costa Mesa, CA 92626, USA | Tel: 1-866-294-9244
© 2023 KODA. All rights reserved.
MADE IN CHINA
TM
ML-030377_V1
Table of contents
Other KODA Work Light manuals