Voltage
Operating temperature range
Vibration resistance
Shock resistance
注:cタイプの使用サイズは左右50mm未満
このデータからの縮率は50%より小さく
Y142171
Ver.8.0
■
Single and double solenoid switching procedure
(Except 3-position valves and tandem 3-port valves)
By switching the manual override, model F□T1(2-position valve)
can be used as either a single solenoid valve or a double solenoid
valve (switching not possible with a 3-position valve and a tandem
3-port valve). Note that the F□T1 is set to the single solenoid
specification at shipping.
●
Switching from a single solenoid valve to a double solenoid valve
1.
As shown in Fig.1, insert the flatblade edge of a small screwdriver
into the gap between the valve and the cover, and then peel it off
and remove the cover.
As shown in Fig.1, make sure to insert a small screwdriver from the
side of the valve cover. The cover claw may be damaged when the
cover is removed from the direction of the valve stem. Never
remove the cover for any reason other than valve function
switching.
2.As shown in Fig.2, use a small screwdriver, etc. to turn the manual
override on the B side by 90 degrees in the counterclockwise
direction, so that the manual override button’s slit is horizontal, as
shown on the right side of the figure. Then the unit can be used as
a double solenoid valve. When using it as a double solenoid
valve, the button is used as the manual override button for the B
side.
●
Switching from a double solenoid valve to a single solenoid valve
As shown in Fig.3, use a small screwdriver, etc. to push lightly
against the manual override button, and then turn it by 90 degrees
in the clockwise direction, so that the manual override button’s slit
is in the vertical direction, and then attach the cover.
The cover has directionality (F15 and F18 series only). When
attaching, always align the detent on the back of the cover with
the manual override button’s slit, as shown in Fig.4.
1. When using it as a double solenoid valve, do not attach the
cover that was removed in Fig. 1.
2. Be aware that even if the valve has been switched to a double
solenoid, no power will be supplied to the B side solenoid
unless the valve base wiring is set to the double wiring
■Precautions for use of the double solenoid
When using models F□T1 or F□T2 (2-position valve) as double
solenoid valves, caution should be exercised as energizing the A
side solenoid or pushing the manual override button on the A side,
while pushing the B side manual override button or in a locked
state, or energizing the solenoid on the B side, will cause the valve
to switch over the valve position. (At that time, the valve will
operate in the same state as the single solenoid valve.)
■
Dual use fittings
(With dual use fitting blocks)
The F series dual use fitting blocks employ dual use fittings for dif-
ferent tube sizes, which can connect tubes of 2 different outer
diameters. (Excluding ports 1(P) and 3, 5(R) of F18 series.)
●Attaching and removing tubes
When connecting tubes, insert an appropriate size tube until it con-
tacts the tube stopper, and then lightly pull it to check the connec-
tion. For tube removal, push the tube against the tube stopper,
then for large tube sizes, push on the release ring and at the same
time pull the tube out. For small tube sizes, push on the outer ring
by pressing the release ring and simultaneously pull the tube out
(see Fig. 5).
1. Always stop the air supply before operation.
2. Firmly tighten the screws after completing a re-combination.
Recommended tightening torques are shown below.
3. Perform piping carefully in regards to the locations of each con-
nection port (see Figs. 7, 8).
4. Care should be taken not to lose the gaskets while changing
plates.
■Piping
Base piping and direct piping
can be switched by replacing the
plate with a fitting block or a
female thread block (see Fig. 6).
●Attaching fittings to female thread blocks
When attaching fittings to female thread blocks, secure with the
tightening torques shown below or less.
●Attaching fittings to piping blocks〔F18Z(G)-PM(P) 〕
To attach fittings to the female thread type piping block of the F18
series, remove the piping block portion (the triangular-shaped block
portion), screw the fittings into the 1(P) and 3, 5(R) ports while
holding the piping block by applying a wrench to its metal portion.
The tightening torque for the mounting (two M3 screws) of the
piping block
after the fittings have been attached should be 49.0
N・cm.
Screw size
Rc1/8
Rc1/4
Tightening torque N・cm
686
882
※
For M5, tighten at the recommended torques for the fittings used.
When attaching or removing tubes, always stop the air supply.
■General Precautions
Mounting
1. While any mounting direction is allowed, be sure to avoid strong
shocks or vibrations applied directly to the body.
2. Avoid using in the locations and environment listed below, as it
could result in malfunction of the valve. If use in such conditions
is unavoidable, always provide a cover or other adequate
protective measures.
● Location directly exposed to water drops or oil drops
● Environment where a valve body is subject to dew
condensation
● Location directly exposed to machining chips, dust, etc
3. In piping connection with valves, flush the tube completely (by
blowing compressed air) before piping.
Intrusion of machining chips or sealing tape, rust, etc.,
generated during plumbing could result in air leaks and other
defective operations.
4. Never use the valve with the 4(A) and 2(B) ports vented to the
atmosphere.
5. When mounting a valve inside a control panel, or when
energizing time is long, make adequate consideration for
ventilation and other heat dissipation measures.
6. When adding or subtracting units in the manifold, or replacing a
fitting block, be sure to tighten to within the specified tightening
torque range.
Media
1. Use air for the media. For the use of any other media, consult us.
2. Air used for the cylinder should be clean air that contains no
deteriorated compressor oil, etc. Install an air filter (filtration of
40 µm or less) near the valve to remove collected liquid or dust.
In addition, drain the air filter periodically.
3. When supply pressure is low, use piping for the 1(P) port with
sufficient tube size.
Lubrication
Can be used without lubrication due to the factory lubricant
(grease). When the pneumatic products require lubrication, use
Turbine Oil Class 1 (ISO VG32) or the equivalent. In addition,
cutting off oil feed while an operation is in progress could lead to
malfunction due to the dissipation of the factory lubricant (grease).
As a result, always keep the oil feed running continuously.
However, use caution since excessive oil feed can also be a cause
of malfunction. Avoid using spindle oil or machine oil.
Atmosphere
The product cannot be used when the media or ambient
atmosphere contains any of the substances listed below.
Organic solvents, phosphate ester type hydraulic oil, sulphur
dioxide, chlorine gas, or acids, etc.
■Specifications of Serial Transmission Compatible
Manifolds
General Specifications
●For details about specifications, see each user’s manual.
24VDC ±10%
5〜50℃
49.0m/s2
98.1m/s2
●Procedure for switching between the base piping type
and the direct piping type
■Usable tubes
Either a nylon or urethane tube can be used.
Use tubes with an outer diameter tolerance within ±0.1 mm of the
nominal diameter, and ensure the ovalness (difference between
the large diameter and small diameter) is 0.2 mm or less.
(Using a Koganei tube is recommended.)
Series
F10
F15
F18
Recommended tightening torque
17.6
49.0
49.0
N・cm
Ver. 8.0
Solenoid Valves F Series
Serial Transmission Compatible Manifold
Instruction Manual
Thank you for purchasing this Koganei product.
Before using it, be sure to read this manual and make sure
you use it correctly.
Figure 1 ※Illustration shows the F10 series.
Caution:
Caution:
Caution:
Caution:
Caution:
Turn the manual override
button in the counterclock-
wise direction to set as the
double solenoid.
B side manual override
button
The manual
override
button is
protruding.
Single solenoid state Double solenoid state
Figure 2
Push lightly, then turn the
manual overrride button
clockwise to set as the single
solenoid.
Manual override button
The manual
override
button is
protruding.
Single solenoid stateDouble solenoid state
Figure 3
Figure 4
Cover
(Back face)
Manual overrride
Detent
End cover
Figure 5
Tube stopper
Release ring
Tube stopper
Release ring
Outer ring
Large tube size Small tube size
チューブ
Plate
2(B) port
Fitting block
4(A) port
4(A) port
2(B) port
Plate
※Illustration shows the F10 series.
Figure 6
※Diagram shows the F10 series.
Note: Caution should be exercised that
the positions of the 1(P) and 3, 5(R)
ports are reversed from their posi-
tions in the F10 and F15 series.
Figure 7
●Direct piping type
For F10, F15 series For F18 series
●Base piping type
Port locations for F10, F15, F18 series are as shown in Fig. 8.
ABABABABAB
1(P)
port
3, 5(R)
port
2(B)
port
4(A)
port
※Diagram shows the F10 series.
1(P)
port
3, 5(R)
port
2(B)
port
4(A)
port
F18-シリアル寸法-直接配管
AB AB ABABAB
1(P)
port
3, 5(R)
port
2(B)
port
4(A)
port
Note
Note
Figure 8
* For other details about specifications and precautions,
see the catalog.
* For inquiries about the product, contact the Koganei
overseas department at the number below.
OVERSEAS DEPARTMENT
3-11-28, Midori-cho, Koganei City, Tokyo 184-8533,
Japan
Tel: 81-42-383-7271 Fax: 81-42-383-7276
■Serial Transmission Block, Terminal Block (LED) Part Names
24V 0V
PWR ERR
LOAD
OFF HOLD
ERR SIG
Output selecting switch in faulty operation
O
N
1
2
3
4
5
6
PWR
COMM
ERR
Dipswitchesforvarioussettings
BS
−
FGBS
+
BDH BDL
通信コネクタ 電源コネクタ
O
N
0
9
8
7
6
5
4
3
2
1
PW
L RUN L ERR.
S DRD
O
N
Dip switches for various settings
DA
DB
DG
SLD
24V
(FG)
0V
●
For OMRON B7A Link Terminal
Transmission block specification: -31 (standard type), -32 (high-speed type)
LED indicator
Indicator Description
PWR Lights up when power is turned on
ERR Lights up during faulty transmission
Remarks
●Connection method: 1 to 1
(Transmission block spec.)
Standard type (-31) High-speed type (-32)
Transmission delay time
Max. 31 ms Max. 5 ms
Transmission distance
Max. 500 m [1640 ft]
Max. 100 m [328 ft]
※For details of B7A Link Terminal, see the OMRON
catalog, user’s manual, etc.
●
Number of outputs per block
Maximum of 16 solenoids
● Error output specifications
Output type: NPN open collector
Rated load voltage: 24VDC
Output current: Sink current MAX. 40 mA
●
Related materials: User’s manual, document No. BK-HV038
●
F10 , F15 and F18 series are supported
●For OMRON CompoBus/S
Transmission block specification: -A1 (16 outputs)
Remarks
※
For details of CompoBus/S, see the OMRON catalog,
user’s manual, etc.
●
Number of outputs per block
16 solenoids (transmission block specification: -A1)
●
Related materials: User’s manual, document No.BK-HV040
●
F10 and F15 series are supported
Lights up
Shuts off
Lights up
Shuts off
Lights up
Shuts off
Green
Yellow
Red
LED indicator
Indicator State Color Description
PWR
COMM
ERR
During power supply
Power not supplied
During normal communication
Communication fault, or standby
Communication fault occurred
During normal communication, or standby
●For CC-Link
Transmission block specification: -B1 (16 outputs)
Remarks
※
Conforms to CC-Link.
●
Number of outputs per block
16 solenoids (transmission block specification: -B1)
※
Since the block occupies 1 station, if remote I/O stations
are entirely composed of the blocks, a maximum of 64
units can be connected to 1 master station.
●
Related materials: User’s manual, document No.BK-HV041
●
F10 and F15 series are supported
LED indicator
Indicator Description
PW
L RUN
SD
RD
L ERR.
Lights up when power is turned on
Lights up when normal data is received
from master station
Lights up during sending data
Lights up during receiving data
Lights up during transmission errors, and shuts
off when time is over
Lights up due to station number setting error or
transmission speed setting error
PW
L RUN L ERR.
S DRD
DA
DB
DG
SLD
24V
(FG)
0V
0
8
6
4
2
0
8
6
4
2
0
8
6
4
2
B RATE STATION NO.
×10 ×1
Station number setting switches
Tr ansmission speed setting switch
HOLD
CLEAR
HOLD/CLEAR switch
●For CC-Link
Transmission block specification: -B3 (32 outputs)
Remarks
※
Conforms to CC-Link.
●
Number of outputs per block
32 solenoids (transmission block specification: -B3)
※
Since the block occupies 1 station, if remote I/O stations
are entirely composed of the blocks, a maximum of 64
units can be connected to 1 master station.
●
Related materials: User’s manual, document No.BK-HV041
●
F10 and F15 series are supported
LED indicator
Indicator Description
PW
L RUN
SD
RD
L ERR.
Lights up when power is turned on
Lights up when normal data is received
from master station
Lights up during sending data
Lights up during receiving data
Lights up during transmission errors, and shuts
off when time is over
Lights up due to station number setting error or
transmission speed setting error
Remarks
※Conforms to DeviceNet.
● Number of outputs per block
A maximum of 16 solenoids
(transmission block specification: -D1)
A maximum of 32 solenoids
(transmission block specification: -D3)
●
Related materials: User’s manual, document No.
BK-HV042
●
F10 and F15 series are supported
●For DeviceNet
Transmission block specification: -D1 (16 outputs), -D3 (32 outputs)
Lights up
Flashing
Lights up
Flashing
Shuts off
Lights up
Flashing
Lights up
Flashing
Shuts off
LED indicator
Indicator State Color Description
MS
NS
Normal state
No setting state
Serious breakdown
Minor breakdown
No power supply
Communication connection completed
No communication connection
Serious communication fault
Minor communication fault
No power supply
Green
Red
Green
Red
通信コネクタ 電源コネクタ
Dip switches for various settings
V
−
CAN L
Drain
CAN H
V
+
O
N
0
9
8
7
6
5
4
3
2
1
MS NS
24V
0V
FG
Remarks
※Conforms to CompoNet.
● Number of outputs per block
16 solenoids (transmission block specification: -H1)
●
Related materials: User’s manual, document No.BK-HV043
※The communication connector is sold by Omron
Corporation. Direct your inquiries to Omron.
●
F10 , F15 and F18 series are supported
●For CompoNet
Transmission block specification
:-H1 (16 outputs)
Lights up
Lights up
Flashing
Shuts off
Lights up
Flashing
Lights up
Flashing
Shuts off
Green
Red
Red
−
Green
Green
Red
Red
−
LED indicator
Indicator State Color Description
MS
NS
Normal state
Serious breakdown
Minor breakdown
Power OFF/In preparation
Online/Access state
Online/No-access state
Serious communication fault
Minor communication fault
Power OFF/In preparation
MS
NS
24V
BS+
BDH
BDL
BS−
0V FG
0
8
6
4
2
0
8
6
4
2
×10 ×1
Node address setting switches
From left ×10, ×1
●For OMRON CompoBus/S
Transmission block specification: -A1 (16 outputs)
Remarks
※
For details of CompoBus/S, see the OMRON catalog,
user’s manual, etc.
●
Number of outputs per block
16 solenoids (transmission block specification: -A1)
●
Related materials: User’s manual, document No.BK-HV040
●
F18 series are supported
●
F10 and F15 series ( previous model) are
supported
Lights up
Shuts off
Lights up
Shuts off
Lights up
Shuts off
Green
Yellow
Red
LED indicator
Indicator State Color Description
PWR
COMM
ERR
During power supply
Power not supplied
During normal communication
Communication fault, or standby
Communication fault occurred
During normal communication, or standby
O
N
1
2
3
4
5
6
PWR
COMM
ERR
Dip switches for various settings
FGBS
−
BS
+
BDH BDL
●For CC-Link
Transmission block specification: -B1 (16 outputs)
Remarks
※
Conforms to CC-Link.
●
Number of outputs per block
16 solenoids (transmission block specification: -B1)
※
Since the block occupies 1 station, if remote I/O stations
are entirely composed of the blocks, a maximum of 64
units can be connected to 1 master station.
●
Related materials: User’s manual, document No.BK-HV041
●
F18 series are supported
●
F10 and F15 serie s (previous mo del) are
supported
LED indicator
Indicator Description
PW
L RUN
SD
RD
L ERR.
Lights up when power is turned on
Lights up when normal data is received
from master station
Lights up during sending data
Lights up during receiving data
Lights up during transmission errors, and shuts
off when time is over
Lights up due to station number setting error or
transmission speed setting error
DB DA
0
8
6
4
2
0
8
6
4
2
0
8
6
4
2
24G
+24V
SLD DG(FG)
PW
L RUN L ERR.
S DRD
HOLD CLEAR
B RATE STATION NO.
×10 ×1
Station number setting switches
Tr ansmission speed setting switch
HOLD/CLEAR switch
EtherCATRis a registered trademark and patented technology,licensed by Beckhoff Automation GmbH,Germany.
●EtherCAT Compliant
Transmission block specifications: -K1
(16 outputs)
, -K3
(32 outputs)
●EtherNet/IP Compliant
Transmission block specifications: -M1
(16 outputs)
, -M3
(32 outputs)
LED indicator
LED indicator
Remarks
*EtherCAT compliant.
●Number of outputs for this block
Number of solenoids for -K1 is 16
and for -K3 is 32.
●
Related materials: User’s manual, docu-
ment
No. BK-HV044
●F10 and F15 series are supported
Remarks
*EtherNet/IP compliant.
●Number of outputs for this block
Number of solenoids for -M1 is 16
and for -M3 is 32.
●
Related materials: User’s manual, docu-
ment
No. BK-HV045
●F10 and F15 series are supported
Indicator State Color Description
Sys.Run/Sys.Rdy
Lit/Not lit Green/yellow Transmission block operation normal
Flashing/flashing Green/yellow Transmission block initialization
Not lit/lit or flashing Green/yellow Transmission block error
Not lit/Not lit Green/yellow Transmission block power OFF
Run
Off Green INIT
Flashing (blinking) Green PRE-OPERATIONAL
Flashing (single flash) Green SAFE-OPERATIONAL
Lighted Green OPERATIONAL
Err
Off Red No error
Flashing (blinking) Red Invalid setting
Flashing (single flash) Red Unrequested change in status
Flashing (double flash) Red Communication disconnect
L/A OUT
L/A IN
Lighted Green Normal communication
Flashing Green EtherCAT frame sending/receiving
Off Green Not connected
Y S 7 K 1
F G
G
2 4
( NC )
S y s . R u n S y s . R d y
R u n
E r r
L / A OU T
L / A IN
H / C
ECATID
× 1
× 1 0
× 1 0 0
1 4 3 1 2 9
Address setting switch
(NC): Not used
H/C: HOLD/CLEAR switch
Communication connector (L/A OUT)
RJ-45
Communication connector (L/A IN)
RJ-45
Power supply connector (4 contacts)
Screw in type
0
5
1
3
9
7
6
8
4
2
0
5
1
3
9
7
6
8
4
2
0
5
1
3
9
7
6
8
4
2
B
A
B
A
Sys.Run Sys.Rdy
MS
NS
L/AOUT
L/AIN
HOST
YS7M1
143147
NETWORK
H/C
× 1 0 0
× 1 0
× 1
A
Sys.Run Sys.Rdy
MS
NS
L/AOUT
L/AIN
HOST
YS7M1
143147
NETWORK
H/C
× 1 0 0
× 1 0
× 1
Hostaddresssettingswitch
HOLD/CLEARswitch
NETWORKaddresssettingswitch
24
G
FG
Communicationconnector(L/A OUT)
RJ-45
Communicationconnector(L/A IN)
RJ-45
Powersupplyconnector(4terminals)
Screwintype
FGterminal
Indicator LED State Description
Sys.Run/Sys.Rdy o/o Transmission block power o
Lit green/o Transmission block normal operation
MS
O Transmission block power o
Flashing green IP address setting in progress
Lit green Normal operation
Flashing red Recoverable errors
Lit red Unrecoverable error
NS
O Transmission block power o
Flashing green Transmission block is online without an established connection
Lit green Transmission block is online and has established connections
Flashing red Connection timeout
Lit red Transmission block detected a duplicate IP address
L/A O Not connected
Lit green Normal communication
EtherNet/IPTM is trademark of ODVA.