Kohler S600GP User manual

Installation and Homeowners Guide
Veil Bathroom Heater S600GP
S600GP
K-24619T-G-0
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,
JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
( ) 158 200436
1374352-T01-D

CCC
30mA
2.3m
220V 50Hz
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
WARNING: Risk of electrical shock.
Warning: Danger of electric shock.
Warning: Danger of electric shock.
Warning: Danger of electric shock.
Warning:
Warning:
Warning:
Warning:
Warning:
A licensed
electrician should make all electrical connections.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
Disconnect
power before servicing.
The appliance
shall be installed according to the national wiring rules.
Otherwise, it may cause electric shock or fire.
This product
must be used under the power supply with leakage
protection switch conforming to CCC (the leakage
current is below 30mA). Otherwise, it may cause
electric shock and fire.
The power must
be cut off before any cleaning and maintenance.
After the installation of the product, the
distance between the bottom of the product and the
ground must be greater than 2.3m.
The installation of the product should make
the switch and other controllers inaccessible to people
in the bathtub or shower area.
It is forbidden to use the power beyond the
rated voltage of 220 V~, 50 Hz. Otherwise, it will
damage the product and cause fire.
In order to avoid the danger caused by the
false reset of the thermal circuit breaker, the appliance
can not be powered by external switching devices,
such as timers or connected to the circuit which is
regularly on and off by common components.
Do not install near curtains and other
combustible materials. Otherwise, combustibles may
be ignited.
-1-
BEFORE YOU BEGIN
!
!
!
!
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -
.
This product complies with GB4706.1-2005, GB4706.23-
2007, GB4706.27-2008, GB7000.1-2015, GB7000.202-
2008, GB/T 17743-2017 and Q31/0106000060C022-2020.
please leave instructions for the
consumer
!
!
!
!
,
-
GB4706.1-2005 GB4706.23-2007
GB4706.27-2008 GB7000.1-2015 GB7000.202-
2008 GB/T 17743-2017Q31/0106000060C022-2020
©
©
Copyright Kohler China Investment Co., Ltd. 2021
2021
1374352-T01-D

!
!
!
!
!
!
!
!
!
!
Tape measure
Level
Screw driver
Connection wire
Wire cutter
Insulation tape
Bushing
Percussion Drill
Pen Knife
Wrench
!
!
!
!
!
!
!
!
!
!
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
Kohler reserves the right to change marked dimensions without prior notice.
Unit: mm
:
Reference Value
ROUGHING-IN
Junction Box CoverVentilation Outlet
Hot Air Outlet
Kohler Logo
564
595
600
300 295 268
167
135
Inlet(where filter mat is installed)
()
Warning:
Warning:
Warning:
Warning:
It is forbidden to place the product directly
under the power socket. Otherwise, it may cause fire.
It is forbidden to use methods other than
those specified in this manual for installation.
Otherwise, the product may fall and cause injury.
This product must be grounded safely.
If the power cord is damaged, in order to
avoid danger, it must be replaced by professionals
from the manufacturer, its maintenance department or
similar departments.
-2-
1374352-T01-D

-3-
SPECIFICATIONS
Model K-24619T-G-0 K-24619T-G-0
Rated Input Power 2750W 2750W
Heater Power
Fan Power
Dry Clothing Power
Ventilation Power
2731W 2731W
30W 30W
2600W(Hot)/60W(Cool) 2600W( )/60W( )
33W 33W
Lighting Power
Ventilation Volume
Ventilation Noise
Ingress Protection
19W 2 (108pcs 0.2W) 19W 2 (108 0.2W)
m /min
3
3.3 3.3m /min
3
43dB (A) 43dB (A)
IPX2 (Bathroom Heater) IPX2 ( )
IPX4 (Remote Control) IPX4 ( )
SIMPLIFIED DIAGRAM OF THE UNIT
Expansion Pipe
M6 Screw Rod
M6 M6 Butterfly Nut
M6
Hanger
Ventilation Outlet Assy.
Clamp
M6 Nut
M6
6 Spring
Washer
6
6 Washer
6BTP4*8 Triangular
Self Tapping Screw
BTP4*8 Air Outlet Window
Air Exhaust Pipe
Decorative Screw Cover
ST4.2*8 Self-tapping Screw
ST4.2*8
Plasterboard Ceiling
IP20 IP20
!
!
!
!
The rated input power is measured at the factory.
The exhaust air volume, air change noise and other data
are the test results of Kohler company, which are all
central values, which are measured under the static
pressure of 0 Pa. The error of exhaust air volume shall not
be less than 90% of the express value.
The ventilation noise value is A weighted average sound
pressure level, which is the central value of Kohler
company's test results, and the measured value does not
exceed the stated value + 3dB. In the semi anechoic
chamber, five points on the plane 1 meter below the
sample and four points on the plane of the air outlet of the
sample are operated under rated voltage and rated power,
and the average noise value of nine points is taken.
The body of this product has passed the drip-proof water
test and meets the requirements of IPX2.
The above parameters are subject
to change without prior notice
!
!
!
!
0Pa
90%
A
+3dB
15
9
IPX2
LED Ingress Protection
Rated Voltage
And Frequency 220V~, 50Hz 220V~ 50Hz
1374352-T01-D

WIRING DIAGRAM
K-24619T-G-0
-4-
MAIN CONTROL CIRCUIT BOARD
CAPACITOR
ALL-POLE SWITCH (OPTIONAL)
220V
50Hz
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 20A
250V 20A
HOT MOTOR
VENT MOTOR
YELLOW/GREEN
/
HEATER 1 1
HEATER 2 2
THERMOSTAT
THERMAL FUSE
OVER CURRENT FUSE
CAPACITOR
CN4
P5
P4
P3
P2
P1
CN7
CN8
CN5
CN12
CN6
CN3
CN2
CN11
CN14
STEPPER MOTOR
STEPPER MOTOR
RED
RED
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
RED
RED
RED
RED
BLACK
WHITE
WHITE
WHITE
BROWN
GRAY
GRAY
PINK
PINK
YELLOW
YELLOW
ORANGE
ORANGE
LED POWER
LED
+
+
+
+
+
+
There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.5mm .
,
GB/T 5023.5 60227 IEC 53 ,
3X1.5mm
2
2
Terminal
Conductor
Insulation 8
(Unit: mm)
(: )
WARNING
Make sure the power cord installed firmly,
otherwise it may catch fire.
Conductor
Earth
Power Cord
8
45
25
1374352-T01-D

-5-
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installation A.
1. Open the hole of outlet window
Make sure that the outlet window's position (it should be
lower than the outlet of the bathroom heater to prevent the
water come back to the bathroom heater from the outlet
window), and open a round hole on the wall.
2. Outlet window installation
Sealing one end of the air exhaust pipe to the outlet
window on the wall with the clamp, and fix the other end to
ventilation outlet assembly with the clamp.
3. Make a Mounting Hole
Locate the position of the bathroom heater and make the
holes with the installation template (Hole Size 275 mm *
575 mm ). Bring the power cords and ventilation outlet
assembly to the hole edge on the plasterboard.
The keels should not be placed on the edges of the
installation holes to ensure that the ventilation outlet
assembly could be installed correctly.
+5
0
+5
0
Note:
1.
(
)
2.
,
3.
:
275 mm * 575 mm
+5
0
+5
0
Ceiling
Air Exhaust Pipe
Wall
Inner Wall Outer Wall
Outlet Window
Outer wall installing. Inner wall installing.
Outlet Window
Outlet Window
Hole on the Wall Hole on the Wall
120mm
120mm
110mm
110mm
Plasterboard
Ceiling
Installation Hole Mark
Install Template
Power Cord
Ventilation
Outlet Assy.
Installation Hole
Please avoid the keels.Note:
B. Take out the bathroom from package. B.
Bathromm Heater
1374352-T01-D

-6-
1367446
100 Air Outlet Window
100
1374343
100 Air Exhasut Pipe
100
1285549
Clamp
2
1367441
Fixed Column Assy.
M6 Expansion Head
M6
10 Expansion Pipe
10
M6 Screw Rod
M6
1285553
Lock Assy. /
M6 Butterfly Nut
M6
6 Washer
6
6Spring Washer
6
M6 Nut
M6
Note: Initial Length: 150mm
Stretch Length: 2200mm
150mm
2200mm
305mm
C. Packing List C.
Remote Control
1373399
Ventilation Outlet Assy. S600G
S600G
BTP4 8 Triangular
Self Tapping Screw
BTP4 8
Cover
*2
M4*25 Screw
*2
Base
6 Plastic
Expansion Pipe
6*2
Remote Control Base Assy.
Remote Control Assy.
Hanger
Triangular
Self-tapping Screw
BTP4*8
1373457
Heater Accessories Assy.
1373401
Installation Template
S600G
S600G
1373458
Wooden Bar
1374352-T01-D

-7-
INSTALLATION
Caution before installation:
!
!
!
!
!
!
The installed product must be 200mm or above away from
curtains or other combustible materials.
The distance between the ceiling where the product is
mounted and the roof shall be 200mm or above.
Ensure that the gap between the product edge and the
wall is 300mm or above.
The power cord to the product shall have enough length
for the installation.
The distance between the product and the air outlet
window shall be 2000mm or lower.
Cut the screw rod(M6) to suit the distance between the
ceiling and the roof.
!
!
!
!
!
!
200mm
200mm
300mm
2000mm
(M6)
Air Exhaust Pipe
Wall
Under 2000mm
2000mm
Above 300mm
300mm Above 300mm
300mm
Air Outlet Window
1. Installing the Main Body Method 1 Plasterboard Ceiling.
(1) Bend the installation template to 90 at the bending line.
Push the template to the marked location.
°
1.
(1) 90
M6
M6
Install Template
Cement Board
Bending Line
Install Template
Plasterboard
Ceiling
Ventilation
Outlet Assy.
Installation Hole
Marked Hole
179
179
1374352-T01-D

-8-
(2) Plug the M6 screw rod on the cerement board and
attach the hanger to the rod as the diagram shows. Fix
two wooden bars to the hanger with 8 ST 4.2*10
triangular screws.
(2) M6
M6
ST4.2*10
(8pcs)
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
Hanger Clinging to Plasterboard
Ventilation
Outlet Assy.
Wooden Bar
ST4.2*10 Triangular
Self Tapping Screw
ST4.2*10
(3) Demount five decorative screw covers. (3) 5pcs
Decorative Screw Cover
1374352-T01-D

-9-
(5) Push the bathroom heater to hole and install the
ventilation outlet assembly first with 1 ST 4.2*8 self-
tapping screw.
(5) ,
ST4.2*8 (1pc)
(4) Fix the power cord to the bathroom heater
(I) Remove the screw on the wiring cover plate.
(II) Open the wiring cover plate.
(III) Lift the terminal protection cover.
(IV) Loosen the screw fixing the power cord clip.
(V) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor
fixed line into the wiring terminal, tighten the wring
terminal screw.
(VI) Fix the power cord with power cord clips. (The
power cord clip must pin the insulation sheath of
power cord.)
(VII) Use the screw removed in step (I) to fix the wiring
cover plate again.
(4)
(I)
(II)
(III)
(IV)
(V)
()
(VI) (
)
(VII) (I)
Power Line
Terminal
Junction Box Cover
Wire Clamp
ST2.9*7 Self-tapping Screws
ST2.9*7
Installation Hole
Ventilation
Outlet Assy.
Plasterboard
Ceiling
Push-in
ST4.2*8 Self-tapping Screws
ST4.2*8
Ventilation Air Outlet
Panel Base
Ventilation Outlet
Assy. Hook
Groove
1374352-T01-D

-10-
(6) After the bathroom heater is fully inserted into the hole.
Fix the hanger with the heater by using 8 BTP 4*8
triangular self-tapping screws. Finally, put back the
decorative screw covers.
(6)
BTP4*8
(8pcs) (
)
(5pcs) ( )
Decorative
Screw Cover
Plasterboard
Ceiling
Plasterboard
Panel Base Panel Base Clinging to Plasterboard
BTP4*8 Triangular
Self-tapping Screw
BTP4*8
2. Installing the Main Body Method 2 Ceiling mounting has
not been installed.
(1) Positioning and installation of the suspenders
1) Mark the holes of screw rods on the cement board as
the figure shows.
2.
(1)
1)
90
180
°
°
Install Template
Cement Board Marked Hole
Marked Hole
Marked Hole
Center Line
1374352-T01-D

2) Make the holes at the marked position. 2)
Cement Board
Suspender
-11-
(2) Demount five decorative screw covers. and install the
ventilation outlet assembly first with 1 ST 4.2*8 self-
tapping screw.
(3) Fix the hangers to the heater with 8 BTP 4*8 self-
tapping screws. And put back the 5 pcs decorative
screw covers.
(2) (5pcs)
ST4.2*8 (1pc)
(3) BTP4*8 (8pcs), ,
(5pcs)
BTP4*8 Triangular
Self Tapping Screw
BTP4*8 (4 )
(4) Hang the bathroom heater on the ceiling with the screw
rods and modify the levelness. Finally tightening the
screws.
(4) ,
Hanger
Decorative Screw Cover
Decorative Screw Cover
ST4.2*8 Self-tapping Screws
ST4.2*8 (1 )
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
(5) Fix the pipe and ventilation outlet assembly with the
clamp.
(5)
Outdoors
Indoors
Slant Taper 1
100
1
50
~
()
Ventilation Outlet Assy.
Clamp
Air Exhaust Pipe
1374352-T01-D

-12-
NOTE:
NOTE:
If the wall for installation is made of special material
(such as wood board, density board and etc.), suitable fixing
methods shall be adopted.
The place to install the remote controller shall not be
easily splashed by water.
Choose a mounting location for the remote holder.
Drilling two holes with depth larger than 45mm on the wall by
drill with a diameter of 6mm in accordance with the position of
screw holes on the remote control holder. Installing the
expansion tube into the holes.
Placing the installation holder on the fixing hole.
Fixing the holder with screws and install it.
Installing the screw covers on the screws.
Placing the remote controller on the holder.
6mm
45mm
INSTALLATION OF REMOTE CONTROLLER HOLDERINSTALLATION OF REMOTE CONTROLLER HOLDER
Remote Control
Cover
Screw
Base
Expansion Tube
INSTALLATION OF NO. 7 BATTERYINSTALLATION OF NO. 7 BATTERY
Please follow the installation diagram.
A.
!
!
27
1374352-T01-D

-13-
B.
//
//
(3 3)
24
()
C.
E. ( )
10
30 30
-
-10
-24 10
24
-
!
!
!
D.
+ - 00:00
(/
00:00 )
24
24
24
!
!
!
!
!
!
24
F.
+-
3306
3306
/ 3 30 3
30 6
24 24
30
!
!
!
!
!
!
!
1374352-T01-D

G.
40 C + -
10
40 C 40 C 30 C
°
°°°
!
!
H.
!
I.
3
*
!
!
!
!
!
-14-
1374352-T01-D

-15-
TROUBLESHOOTING
Problem Diagnosis Solution
Bathroom Heater does not
work.
The remote controller
does not display.
The remote controller
does not work.
A "Beep" alarm is on when
turn on "Heater",
"Ventilation", "Air-Care"
and "Cloth Dry".
A. A power failure occurred.
A. The battery has been used up.
A. No pairing with the bathroom heater.
A. Dust filter need be cleaned.
B. The power cord is disconnected.
B. The polarity of battery was installed inversely.
B. The remote controller is used in an
inappropriate position or angle.
C. Circuit breaker is in the "Off" position.
C. No wake-up.
C. Low battery.
A. Wait until the power is restored.
A. Please replace the battery.
A. Make the pairing.
B. Connect the power cord into the junction box
of bathroom heater.
B. Please install the battery correctly.
B. Change the using position or angle to make
the controller towards the bathroom heater.
C. Turn on the power at the breaker.
C. Press any key to wake-up.
C. Change the battery.
A. Clean the filter or press the "+" for 2 seconds
in the Activated Mode.
A.
A.
A.
A.
B.
B.
B.
C.
C.
C.
A.
A.
A.
B.
B.
B.
C.
C.
C.
A. + 2
()()
CARE & CLEAN (PROFESSIONAL ONLY)
1. Shut off the power source, and turn around the wind swing
assembly manually.
1.
Wind Swing Assy.
1374352-T01-D

2. Hold the two ends of the filter, and take it off by pulling the
assembly.
2.
-16-
Filter
Filter
Holding Here
3. After the filter is cleaned, put it back to the wind swing
assembly, on which there is an arrow symbol. Please make
sure that the printed point is well matched with the mark to
install the filter correctly. Finally, turn on the power and the
wind swing assembly will restore automatically in 5
seconds.
3.
(
)5
Filter Printed Point
Filter Mark
1374352-T01-D

-17-
1. 220V
W41-0146
2. -10 40
3.
4.
5.
6.
7.
8.
9.
10. 7
°°C~ C
1374352-T01-D
This manual suits for next models
1
Table of contents
Other Kohler Heater manuals

Kohler
Kohler K-77316T-C-MZ User manual

Kohler
Kohler S600 Series User manual

Kohler
Kohler K-21465T-G-0 User manual

Kohler
Kohler K-77316T-MZ User manual

Kohler
Kohler S450P User manual

Kohler
Kohler S300 User manual

Kohler
Kohler S300 User manual

Kohler
Kohler K-77283T-2-MZ User manual

Kohler
Kohler S300 User manual

Kohler
Kohler S450 User manual