Kongskilde FAST User manual

OIL-FIRED
AIR HEATER
FAST
TECHNICAL INFORMATION
ASSEMBLING INSTRUCTIONS
USE AND MAINTENANCE

2
CONFORMITY

3
FAST heaters are produced according to :
•Machinery Directive 89/392/CEE, 91/368/CEE, 93/44/CEE and 93/68/CEE
•Low Voltage Directive 73/23/CEE.
RANGE
MODEL
FAST 35
FAST 60
FAST 95
FAST 110
Dear Customer,

4
Thank you for choosing our FAST air heater a new, modern and high quality product that
guarantees efficiency at all times. The heater is very quiet and safe specialy when
maintenance is made by our KONGSKILDE Technical Service.
The instruction manual contains important information that must be followed to install
and operate the FAST heater.
We thank you again for choosing our products.
KONGSKILDE A/S
WARRANTY
The FAST heater is covered by a specific warranty that becomes effective from your customers
purchase date, this must be proved by documentation, otherwise the production date will be used.
All warranty conditions are listed in the “WARRANTY CERTIFICATE” that is supplied together with
the heater, therefore we suggest you read it very carefully.

5
INDEX
Page
1 Conformity 3
2 Range 3
3 Warranty 4
4 Index 5
5 General notions 6
6 Safety rules 7
7 Description of the heater 8
8 Identification 9
9 Parts 9
10 Sizes 10
11 Combustion chamber size 10
12 Technical data 11
13 Handling and transport 12
14 Location 13
15 Head 14
16 Ducting 14
17 Fixed protection 14
18 Electrical connections 15
19 Control board 15
20 Electrical chart 16
21 Tank 17
22 Regulating 18
23 Commands 18
- Room thermostat 18
- Heating/Stop/Fan switch 18
24 Functioning cycles 18
- Working the fan 18
- Working the heater 18
25 Starting and stopping 19
26 Controls 19
27 Maintenance 20
- Cleaning the heat exchanger 20
- Cleaning the oil burner 20
- Fan maintenance 20
28 Location of the flue gas probe 21
29 Servicing 21
30 Malfunctions, causes and remedies 22
GENERAL NOTIONS

6
1) This manual must be considered an integral
part of the machine even when transferred to
another user. It must be carefully conserved
and consulted before any operation. If
damaged or lost your local KONGSKILDE
Technical Assistance Service can send you a
copy.
2) After taking off the packaging, check that
all parts are complete. Otherwise contact your
local Technical Assistance Service.
3) The FAST heater must be installed by a
qualified installer according to the laws in force
in the Country were the heater is placed and
after the installement a valid certificate must
be issued declaring that the heater has been
installed according to the regulations in forcel.
4) These heaters have been designed to heat
environments and for no other use.
KONGSKILDE will not respond, if mentioned or
excluded in any contract, to any responsibilty
regarding damage to people, animals or
objects due to errors when installing, incorrect
regulation or maintenance or improper use.
5) High temperature is not good for health
reasons and is also a waste of electricity. Do
not allow rooms to stay closed for long
periods. Open windows regularly to ensure air
ventilation.
6) When used for the first time, there could be
smoke or bad smells that are caused by the
evaporated liquid that protects the heat
exchanger when stocked. This is considered a
normal effect and stops after a short period. It
is advisable to change the air in the room.
7) If you do not intend to use the machine for
long periods, position the general electrical
network switch on the “off” position.
8) When the heater has not been in use for a
long period it is advisable to contact
KONGSKILDE Technical Assistance Service or
personnel qualified to start the heater.
9) The heaters must exclusively be equipped
with original KONGSKILDE spare parts.
KONGSKILDE is not responsible for damage
caused by incorrect use or not original spare
parts.
10) All references to laws, norms, technical
regulations mentioned in this manual are for
information only and are to be considered valid
at the date the publication is issued. All laws
that become effective or are modified as from
the date of publication will not constitute any
obligation from KONGSKILDE towards any
third party.
11) Repairs or maintenance operations must
be carried out by KONGSKILDE Technical
Assistance Service or by qualified personnel
as mentioned in this manual.
12) All installments (oil hoses, electrical parts,
etc.) must be properly fixed so there is no risk
for anyone to trip over parts.
13) KONGSKILDE must be held responsable
for producing equipment that is compliant with
laws, regulations or directives concerning the
construction of the product. The designer, the
installer and the final user must all be aware of
all laws in force and observe them.
14) KONGSKILDE will not be held responsible
for anyone disregarding instructions held in
this manual, for operations not indicated or for
any translation that may cause a wrong
interpretation of the text.
SAFETY RULES
When using electrical or oil fired equipment there are
some basic rules that must be observed:

7
Children and non assisted disabled people are
not allowed to use the heater.
It is not allowed to use electrical devices such
as switches, household appliances etc. When
one can smell oil or smoke. In such
circumstances it is important to:
•Open windows and doors to improve air
circulation.
•Close the fuel supply.
•Call immediately KONGSKILDE Technical
Assistance or qualified personnel.
It is not allowed to touch the heater with bare
feet when parts of the body are wet.
It is not allowed to carry out maintenance or
cleaning procedures before disconnecting the
heater from the mains by positioning the
general switch on “OFF” and stopping the fuel
connection.
It is not allowed to modify the safety systems
or regulation systems without the
manufacturers authorization or indications from
the manufacturer.
It is not allowed to pull, take off, twist or cut
any electrical cable that comes out of the
heater without the builders authorization.
It is not allowed to open any access door to
internal parts before positioning the heater
switch on “OFF”.
It is not allowed to scatter, abandon or leave
within childrens reach any packaging (such as
carton boxes, staples, plastic bags, etc.) that
could be potentially dangerous.
It is not allowed to install the heater near
inflamable products or in rooms with chemical
products.
It is not allowed to lay objects on the heater or
insert any object inside the grid or in the
combustion discharging duct.
It is not allowed to touch the fuel hose,
because when the heater is functioning it can
reach high temperatures and become
dangerous.
It is not allowed to use adaptors, multiple
jacks, or extentions for electrical
connections.
It is not allowed to install the heater outdoors
or in areas where the heater is exposed to
weather conditions.
It is not allowed to install the heater in small
environments without sufficient air ventilation,
air intake can cause a heavy depression in the
room that can arouse serious problems.
DESCRIPTION OF THE HEATER
The FAST heater functions by using the thermal
energy produced through combustion. The thermal exchange occurs when the air flow,
generated by a centrifugal fan, passes on the surface

8
of the heat exchanger whithout the aid of any
intermedial fluid.
The combustion products, once completed the
thermal exchange, are ejected outside.
This system allows a noticeable reduction of costs on
installament and a reliable and economic use,
particularly ideal for all final users that require
intermittent or irregular heating.
This heater can also be used, in summer, as a
ventilator.
GENERAL MANUFACTURING NOTES:
The heater is composed of the following parts:
•The combustion chamber, of the “flame reversal”
type, is made of AISI 430 stainless steel,
resistent to high temperatures, with a low thermal
charge with different shapes or volumes
depending on the model.
•Tube nest heat exchanger that guarantees a
maximum thermal efficiency.
•Back smoke manifold with inspection door for an
easy access when cleaning pipes.
•Four way head air diffuser with revolving flaps
that can be completely shut for excluding air on
one side.
•External steel epossidic painted panels that can
be dismantled.
•Thermal anti radiant insulation of the surfaces
exposed to heat radiation of the exchanger.
•Hole set to be connected to a ducting system.
•Casing with an inspection door to protect the
burner and the tank.
•Centrifugal fan with two suction inlets,
noiseproof, high performance, single voltage
electrical motor directly connected to a
centrifugal fan.
•Large capacity oil tank equipped with filling hose,
filter and connection fittings to the burner.
•Oil suction burner equipped with electrical control
for fully automatic use.
ELECTRIC PARTS:
•Liquid expansion FAN” thermostat (35°C) which
stats the fan 60 seconds after ignition of the
burner and stops it 4 minutes after the burner
stops. This avoids the cold air exiting when
switched on and expels the heat accumulated in
the heat exchanger once the unit has been
turned off.
•“LIMIT” thermostat (100°C), with a reset manual
switch, that stops the burner when the air is
overheated. When the “LIMIT” switch is
activated, reset only after checking and
eliminating the causes for which it was activated.
•Room thermostat (0-40°C) for automatic
regulation of the room temperature through a
sensor positioned on the air inlet and an
adjusting knob positioned on the central panel.
•Green light indicating electrical voltage.
•Yellow light indicating the “LIMIT” thermostat is
working.
•Red light indicating that the burners electronic
device has stopped.
•3 position switch to set heating, ventilation or to
stop.
IDENTIFICATION
The FAST heater can be identified through a
Technical Data plate where all technical specifications are marked, it is positioned directly inside the burner
cabinet.

9
If the data plate is damaged or lost it is
necessary to request a duplicate from the KONGSKILDE Technical Service.
AIR HEATER
Code
Model
Serial plate number
Country
Thermal input kW
Thermal oytput kW
Air flow (+20°C) m3/h
Electrical feeding
Motor power kW
Maximum current of motor A
IP degree
PARTS
1. Tank
2. Oil burner
3. Electrical board
4. Chimney fitting
5. FAN thermostat
6. LIMIT thermostat
7. Electroventilator
8. Air outlet
SIZE

10
Size (mm) FAST 35 FAST 60 FAST 95 FAST 110
A460 540 680 760
B 1.050 1.120 1.220 1.400
C 1.600 1.700 1.885 2.000
D 1.175 1.305 1.430 1.570
∅Chimney 120 150 180 200
SIZE OF COMBUSTION CHAMBER
The heat exchanger has 3 smoke rings and the combustion chamber has the following size:
Model A BC D E
FAST 35 623 316 120 60 120
FAST 60 683 380 120 60 150
FAST 95 728 476 170 80 180
FAST 110 906 567 170 85 200
TECHNICAL DATA

11
FAST 35 FAST 60 FAST 95 FAST 110
Thermal input kW 46,8 71,1 93,0 104,6
kcal/h 40.300 61.200 80.000 90.000
Thermal output kW 42,2 64,4 83,9 94,2
kcal/h 36.300 55.400 72.100 81.090
Efficiency % 90,1 90,5 90,1 90,1
Combustion chamber volume Dm348,8 77,4 129,5 228,5
Oil consumption kg/h 3,95 6,00 7,84 8,82
Air +20°C m3/h 2.800 4.500 5.300 6.300
∆T°K 43 41 45 45
Thermostat setting
•FAN °C 35
•LIMIT °C 100
Electrical feed 230V 50Hz∼
Motor power kW 0,245 0,590 0,736 0,736
Electrical degree IP 20
Net weight (burner excluded) kg 137 173 197 264
Tank capacity l 55 75 105 135
HANDLING AND TRANSPORT

12
The heaters must only be handled by personnel
properly equipped with machinery capable of handling
the weight of the heater.
If using a fork lift make sure that the fork is inserted
correctly in the slots between the side supports.
BEWARE!
When handling or moving the heater it is important to
be very careful not to damage the heater or harm
people.
When handling or moving the heater it is not allowed
to stay near the unit.
It is not allowed to stack the heaters in layers, it is
also important to line them up correctly not to create
instability.
When moving the heater manually, make sure there is
a sufficient number of people to lift the weight of the
heater for the distance to be covered. The weight of
the machine is indicated at the paragraph
“TECHNICAL DATA”.
We advise the use of gloves when handling the
heater.
LOCATION
The heater must be installed in a specific location
decided by the engineer or by qualified personnel according to technical requirements and Laws or
norms in force. It is advisable to obtain authorizations

13
Near a wall with 3 open
outlets
such as: fire certificates, anti-pollution certificates,
town-planning charts, etc.
It is therefore advisable to obtain all documentation
before installing the heater.
When installing the FAST heater it is important to
keep in mind that :
•the heater must be positioned on well levelled and
dry ground capable of sustaining the weight of the
machine;
•when finding the correct installment location for
the heater one must consider the distance that
allows a correct air flow and allows maintenance
and cleaning procedures to be carried out;
•that there must be a safety distance between the
unit and inflammable materials;
•that it must be positioned near a chimney;
•that it must be positioned near the electrical
supply;
•that it must be positioned so there is easy access
for maintainance or cleaning operations;
•that it must be positioned in a room with air
ventilation according to the Laws in force.
It is not allowed to install the heater :
•when the air is polluted with chemical agents or
aggressive agents;
•when the room is narrow or restricted and the
noise caused by the unit can reverberate or
cause acoustic resonance;
- in dusty environments or where there are leaves
or other particles that could reduce the efficiency
and obstruct the air flow;
- Outdoors
Examples for installment
HEAD
Free zone
In the centre of the room
with 4 open outlets
1 OPEN AIR OUTLET
NOT ALLOWED
Near a wall with 3 open
outlets In a corner with 2 open
outlets

14
The heater is equipped with a4 way head with movable flaps.
The regulation of the flaps must allow:
•a regular distribution of air
•a low air drag
•no interference with people
DUCTING
It is possible, by ducting, to send some of the hot air to other rooms through a hole ( ∅150 for the models FAST
35/60 and ∅300 for the models FAST 95/110) situated on the superior panel on of the head.
FIXED PROTECTIONS
To avoid accidental contact with any moving part of
the heater it is absolutely forbidden to switch on the
heater when it is not provided with its fixed protection
which are:
•Burner inspection panel
•Back panel
ELECTRICAL CONNECTIONS
IMPORTANT!
It is not allowed to let the air exit only
on one side.
1. Set hole
2. Fitting (not supplied)
3. Duct (not supplied)
Inclination
Of flaps

15
The heater is equipped with an electrical board, a fan
motor, thermostats and a burner already connected:
Therefore all connections concern the general
electrical feeding system.
For the connections use the socket positioned
externally according to the specific electrical diagram.
WARNING!!
•The heater must be protected by a magnetic
switch of the right size according to the “technical
data” chart and according to the laws in force.
•Make sure that trained personnel checks that the
cross section of the electric cables and the
electric system are adequate to the maximum
absorbed power of the heater that is indicated on
the the serial plate.
•Always earth the heater, make sure that the earth
cable is longer than the mains, so if accidentaly
pulled it is the last one to cut off.
•Always make sure that the polarity is correct on
all connections.
CONTROL BOARD
1. Voltage indicator (green)
2. LIMIT thermostat indicator (orange)
3. Burner block indicator (red)
4. Switch
5. RESET LIMIT switch
6. Room thermostat
ELECTRICAL CHART
1. 3 pin plug
2. 3 pin socket

16
CAPTION
LF Voltage indicator
LL Limit indicator
LB Burner lock-out indicator
CHeating / stop / fan switch
TA Room thermostat
LM Limit thermostat
FA Fan thermostat
MB Burner terminal board
BBurner
MGV Fan terminal board
GV Fan group
POutside socket
IMT* Magnetic switch
External piece – Not supplied with the heater
TANK

17
The FAST heater is equipped with a tank that not necessarily must be installed inside the heater (if the tank is
positioned far away we can supply a closing panel)
FILLING THE TANK
•Take off the burner panel
•Take off the tank cap
•Fill the tank with a funnel with a filter
REGULATING
1. Closing panel
2. Tank
1. Burner panel
2. Cap
3. Funnel with a filter

18
REGULATING THE OIL BURNER
Only qualified personel can assemble and regulate
the oil burner, following strictly the instruction manual
of the burner.
BEWARE:
All data indicated here is by way of example.
The regulation of the combustion air changes
according to the chimney characteristics, and this
occurs by adjusting the air lock according to the
instructions on the manual.
Regulation chart
RIELLO oil burner
Burner
model Electrical
feed Burner
head
regulation
Air
regulation Pump
pressure
(bar)
Delavan
Nozzle
(G.P.H)
FAST 35 REG 5 230V 50Hz ∼2.0 4.7 11 1.00
60°W
FAST 60 R40G10S 230V 50Hz ∼2.5 4.5 12 1.50
60°W
FAST 95 R40G10S 230V 50Hz ∼5.0 3.2 12 1.75
60°W
FAST 110 R40G10S 230V 50Hz ∼6.0 3.8 12 2.00
60°W
COMMANDS
ROOM THERMOSTAT
It is installed on the unit, its function is to
automatically switch on and switch off the heater in
order to maintain the temperature that has been
selected.
HEATING / STOP / FAN SWITCH
It is positioned on the electrical control board and it
selects the different cycles:
•When set on “heating” the unit automatically
switches on both fan and burner according to the
heat required.
•When set on “fan” the unit automatically switches
off the burner and the fan can be used to cool in
summer.
•When set on “stop” the unit automatically stops.
The fan continues to function for a while to expel
the hot air that is inside the heat exchanger.
FUNCTIONING CYCLES
WORKING THE FAN
Follow these instructions to activate the fan:
•Connect the electricity to the unit
•Position the switch on the “fan” position
In this condition only the fan works so the air exiting
the heat is the same temperature of the air entering.
WORKING THE HEATER
Follow these instructions to activate the heater:
•Connect the electricity to the unit
•Set the thermostat at the temperature required
•Position the switch on “heating”
•The burner is electrically fed and once the pre-
purge has taken place the flame ignites
•One minute after the flame ignites the fan starts
working and hot air exits the unit
•Once the set temperature has been reached
according to the room thermostat the burner stops
working and 4 minutes later also the fan stops.
The whole cycle starts automatically every time that
the rooms temperature is under the temperature set
on the thermostat.
STARTING AND
STOPPING
STARTING
The heater must be started for the first time by
qualified personnel, who must check that the heater
has been correctly installed, the regulation works and
that the safety norms have been observed.

19
Starting the heater for the first time:
•Close the room thermostat contact: the burner
starts its cycle and following the pre-purge the
flame ignites
•Check that the fan starts one minute after
ignition
•Check combustion
•Wait for the heater to reach its steady-state
condition (~20 min.) and check that the LIMIT
thermostat is not functioning
•Open the room thermostat contact and check that
the burner has stopped
•Close the room thermostat and start a new ignition
cycle on the burner
•Close the fuel valve and check the burner is
blocked
•Check the fan stops automatically
ATTENTION
When starting for the first time it is possible that the
burner stops because fuel does not immediately flow
to the burner. If this occurs wait for at least 30
seconds, push the switch and start the same
operation again.
When ignited, during the first few hours, there could
be smoke due to paint or joints being heated. This is
normal and will stop after a few hours.
Alway make sure air ventilation is regular.
STOPPING
Stop the heater EXCLUSIVELY BY ACTING
DIRECTLY ON THE ROOM THERMOSTAT
CONTROLS
To control the heater is working correctly it is
necessary to carry out some basic tests:
•Check that the fan is working about 1 minute from
ignition of the burner.
When the heater is running regularly (after running for
about 20 seconds non-stop):
•Check there is no fuel leakeage.
•Check the correct fuel flow with a fuel-meter (if
possible).
•Check the setting coresponds to the indication in
the “TECHNICAL DATA” section.
•Check the temperature rise corrisponds to
information contained in the “TECHNICAL DATA”
section.
•Open the contact on the room thermostat and
check it works only on the burner and does not
simultaneously stop the fan.
•Check that the current intake value of the motor/s
is not higher than the value indicated on the data
plate.
•Check that the fan rotates for about 4 minutes
from when the burner stops working.
MAINTENANCE
We recommend, to work and conserve the heater
correctly, to clean regularly and carry out
maintenance. Any maintenance operation must be
made only by trained personnel.

20
Maintenance must only be done when the unit is cold
with the electrical and fuel connections switched off.
It is advisable to use protective gloves, and if any
equipment such as ladders etc. are used it is
important to work in safe conditions.
CLEANING THE HEAT EXCHANGER
The heat exchanger should only be cleaned by
qualified personnel following the relevant regulations.
We suggest to clean the heat exchanger at least
once a year. Please follow the instructions below:
FAST 35/60
•Remove the rear panel.
•Remove the fixing screws of the inspection
panels.
•Extract the baffle plate.
•Clean the smoke pipes using a steel brush. Clean
the exhaust gas manifold and carefully remove
residual soot.
•If required replace the inspection door gasket to
ensure a good air-tightness.
•Reassemble all the components taking care not to
forget the baffle plate.
•To clean the combustion chamber extract the
burner from the fixing flange, set it on a flat
surface and remove dirt and soot with a vacuum
or by hand.
1. Rear panel
2. Inspection door
FAST 95/110
•Remove the upper panel.
•Remove the fixing screws of the inspection panel
•Clean the exchanger elements using a steel
brush.
•To clean the combustion chamber extract the
burner from the fixing flange, set it on a flat
surface and remove dirt and soot with a vacuum
or by hand.
•If required replace the inspection door gasket to
ensure it is air-tight
•Reassemble all the components taking special
care they are air-tight.
1. Upper panel
2. Inspection door
CLEANING THE OIL BURNER
The oil burner cleaning operations should be carried
out by qualified technicians who follow the
instructions contained in the instruction manual of the
burner itself.
FAN MAINTENANCE
When cleaning the heat exchanger, also check and
clean the fan rotor.
By disassembling the same panel you can also
collect objects that could have fallen into the lower
vane.
Table of contents
Other Kongskilde Heater manuals
Popular Heater manuals by other brands

STIEBEL ELTRON
STIEBEL ELTRON CNS 50 TREND Operation and installation guide

Midea
Midea NY15EC-7 owner's manual

Viessmann
Viessmann VITOPLANAR EI6 installation instructions

Blaupunkt
Blaupunkt FHM601 owner's manual

Aladdin
Aladdin DH07 Installation, operation & maintenance manual

Hudevad
Hudevad Plan XV installation guide

Honeywell
Honeywell HZ-338 - Sure Set 1500W Ceramic Heater user guide

Euromate
Euromate 107440 instruction manual

EdenPURE
EdenPURE CopperSMART 1000 manual

Space-Ray
Space-Ray LTS 75-L5 Installation and operation instructions

Fenix
Fenix GRT Series Instructions for installation and use

Home & Camp
Home & Camp BL4200C user manual