Step 3: Install the VS-211XS and VS-411XS
Install VS-411XS using one of the following methods:
•Attach the rubber feet and place the unit on a flat surface.
•Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see www.kramerav.com/downloads/VS-411XS).
•Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/product/VS-411XS).
•Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•Avoid uneven mechanical loading.
•Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•Reliable earthing of rack-mounted equipment should be maintained.
•Maximum mounting height for the device is 2 meters.
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your VS-211XS. For best results, we recommend that
you always use Kramer high-performance cables to connect AV equipment to the VS-211XS. VS-211XS and VS-411XS are
identical except for the number of inputs.
Connect the Audio Output:
To a balanced
stereo audio
acceptor:
To an
unbalanced
stereo audio
acceptor:
Setting the DIP-Switches
All DIP-switches are set to Off (up) by default. DIP-switch changes take effect immediately.
OFF (up) –Auto-switching mode.
ON (down) –Manual mode.
OFF (up) –Last connected switching mode: the last detected active source is auto-switched to the output.
ON (down) –Priority switching mode: the device switches the source with the highest priority to the output.
OFF (up) –CEC notifications enabled.
ON (down) –CEC notifications disabled.
It is mandatory to keep set to OFF (up).
For optimum range and performance use the recommended Kramer cables available at www.kramerav.com/product/VS-411XS
Step 5: Connect the power
Connect the power adapter and cord to VS-211XS / VS-411XS and plug it into the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information).
Caution:
•For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•There are no operator serviceable parts inside the unit.
Warning:
•Use only the power cord that is supplied with the unit.
•Disconnect the power and unplug the unit from the wall before installing.
Step 6: Control VS-211XS and VS-411XS
Operate VS-211XS and VS-411XS:
•Remotely, by IP or RS-232
serial commands transmitted
by a touch screen system, PC,
or other serial controller.
•Embedded web pages via the
Ethernet.
RS-232 Control / Protocol 3000
Example: (Switch video input 2 to the output): #ROUTE 1,1,2<CR>
Default IP Parameters –Set to DHCP On
VS-211XS-xxxx (where xxxx are the last 4 digits of the S/N)
When using VS-211XS for the first time, the fallback IP address is set until DHCP server is discovered and a new IP address is acquired.
DHCP discovery is retried every 1 minute, approximately.
To discover IP address:
•Connect to device via Eth and browse to default host name (e.g., http://VS-211XS-0024), where xxx are last digits of the S/N;
alternatively, perform factory reset (via reset button) and browse to fallback IP address.
•Connect to subnet via a router with built-in DHCP server (a basic home router will do) to subnet for identifying subnet-connected
devices via router web-UI, using their unique hostname and/or L2 MAC address.