Kraus FS-1000-B User manual

All-in-One Filtration Set
FS-1000 / FS-1000-B
R
INSTALLATION MANUAL
www.kraususa.com I Toll Free: 1.800.775.0703 I © 2024 Kraus USA Plumbing LLC I REV. January 3, 2024

2
Congratulations on the purchase of your new
Kraus plumbing fixture!
Please keep the box and packaging materials until your product is
completely installed. If you have any questions, require technical
assistance or have any problems with your product:
Please contact our Customer Service Team
1-800-775-0703 / [email protected]
Have the model number available and retain a copy of your
receipt with purchase date for reference.
If for any reason this product does not meet your expectations,
please be sure to repack this product in the original box and
packaging material to avoid damage during transit.
DO NOT RETURN TO STORE
STOP
R

Prior to Installation:
·Make sure you have all necessary parts by checking the diagram and
parts list. If any part is missing or damaged, please contact Kraus
Customer Service at 800-775-0703 for a replacement.
·Read all instructions and safety warnings and ensure you have all
tools, parts, and equipment necessary for a safe installation.
·Observe all state and local plumbing and building codes.
·! CAUTION - Make sure to only install this filtration system to the cold
water supply. To reduce the risk of personal injury, do not install the
system to the hot water supply.
·IMPORTANT - Replace the filter cartridges every 6 months or when the
700 gallon capacity has been exceeded, whichever comes first. You
may also need to replace if you notice a decrease in water flow. The
failure to follow this instruction may affect product performance and
void the warranty.
·IMPORTANT - Flush the system for 10 minutes prior to first use and 5
minutes after prolonged periods of nonuse. The failure to follow this
instruction may affect product performance and void the warranty.
·NOTE: Make sure to mark the installation date on the filter head and
cartridges for your reference.
3
Installation and use must comply with all state and local laws, regulations and
codes.
! CAUTION - To avoid the risk of personal injury, the system is to be
supplied only with cold water.
STOP
R

44
Adjustable Wrench Drill Tape Measure
* To keep the product clean & shining, follow the steps below:
1. Rinse with clean water & dry with a soft cloth.
2. Do not clean with soaps, acid, polish, abrasives or harsh cleaners
as use of such products may affect product performance or void the warranty.
3. Do not use cloth with a coarse surface.
ACID
Utility Knife Permanent Marker
Safety Goggles
Cut Resistant Gloves
Tools Required
Care & Maintenance

55
Diagram and Parts List
1. Tee Adapter
2. Manifold
3. Polypropylene Cartridge
4. Compressed Carbon Cartridge
5. Quick Connect Lock Tab
6. Mounting Screw & Anchor x 3
7. Tubing 1/4" x 8'
8. 3x AA Batteries
9. Battery Compartment
1
2
34
5
6
8
7
9

66
Dimensions and Specifications
Flow Rate 0.7GPM
Capacity: 700 gallons
NOTE: Depending on local water quality and use environment, the actual filtered
water flow rate and total filtered water volume will vary.
Min static pressure: 40 psi (275.8 kPa)
Max static pressure: 120 psi (827.4 kPa)
Inlet Water Temperature 41° - 100° F
! CAUTION - Do not use with water that is micro biologically unsafe or of unknown
quality without adequate disinfection before or after the system.
9 1/2" (240mm)
15 1/2" (394mm)
4 7/8" (125mm)

7
Step 1.
Turn off the cold water supply and
turn on the faucet to relieve the
water pressure and drain water from
the water line. Disconnect the cold
water supply line from the cold water
supply valve. Install the tee adapter
to the cold water supply valve.
NOTE: Make sure to check for
washer in the Tee Adapter before
connecting to the angle stop.
Tee Adapter
3/8" Cold
Water Supply

8
Step 2.
Using the mounting template, mount
the manifold. Align the mounting
holes of the manifold at the proper
mounting location. Mark the hole
locations with a permanent marker.
Place the manifold aside and pre-drill
the mounting holes, if necessary,
depending on the fasteners selected.
Partially thread the screws into the
cabinet wall and slide the manifold
over the screws. Secure the manifold
by tightening the screws.
NOTE: This system is designed for
vertical installation. Make sure that
the bottom of the filter cartridge will
be at least 2" from the bottom of the
cabinet.
Fasteners
Screws
! CAUTION - To avoid the risk of
personal injury, wear safety glasses
and cut resistant gloves with non-slip
grip when drilling.
wall
Position drill holes
as indicated
7.87"(200mm)
Cabinet
Top
Cabinet
Wall
Cabinet
Wall
Cabinet Base
wall
MOUNTING TEMPLATE
Cabinet
Wall

9
Step 3.
Insert the batteries into the battery
compartment by lifting up the tabs.
Drill a 1/4" hole in the wall a few inches
away from your filtration system. Place
the anchor inside the hole and then
fasten the battery compartment to
the wall by screwing it into the anchor.
You can also use the tape on the back
to install it to the wall.
Drill 1/4" Hole
Anchor
Screw
Insert the battery pack cable into the manifold.
! CAUTION - To avoid the risk of
personal injury, wear safety glasses
and cut resistant gloves with
non-slip grip when drilling. Tape

Step 4.
Connect the tubing. Wet one end of the tubing sections with water and press it firmly into
the inlet port of the filter head. Wet the other end of the tubing and press it firmly into the
tee adapter. Repeat for the other end of tubing, pressing one end into the outlet port of
the filter head and the other end into the filtered water faucet supply.
IMPORTANT: Use the quick connect lock tabs to prevent any accidental tube release.
Connect the filter water faucet inlet to the filtered water faucet supply. If you have a
regular kitchen faucet, connect it to the top of the tee. Place the covers onto the filter
head. You may secure the tubing to the cabinet wall using clamps and hardware (not
provided).
IMPORTANT: Water from the supply line must be connected to the filter head inlet. Water
from the filter head outlet must be connected to the faucet. System performance and filter
capacity will be compromised if connected incorrectly.
NOTE: 8 feet of tubing is provided. When cutting the tubing use a sharp utility knife to
make clean and square cuts. Cut the tubing to the lengths needed between the faucet and
filtration system and the filtration system and water supply.
Covers
Inlet
Port
Outlet
Port
Tee
Adapter
Regular Kitchen
Faucet Supply
3/8" Cold
Water Supply
Filtered Water
Faucet Supply
Tubing
Tubing
Quick Connect
Lock Tab
Filter Heads
! CAUTION - To avoid the risk of personal injury, wear cut resistant gloves with non-slip
grip when cutting.
10

11
Step 5.
Install the filter cartridges. Write the
date on the new filter cartridge label.
Remove the cap from the filter
cartridge and discard. Inspect the
cartridge for any damage. Make sure
both sets of O-rings are present and
are positioned correctly. Align the
filter cartridge as shown and press
upward into the filter head. Rotate
the filter cartridge counterclockwise
90° until it is secure in the filter head.
Repeat for the second cartridge.
IMPORTANT: The Polypropylene
Cartridge must be on the left side.
The Compressed Carbon Cartridge
must be on the right side below the
LCD screen.
IMPORTANT: Replace cartridges at
the same time to maintain a proper
performance.
Cap
O-rings
Step 6.
Turn on the cold water supply valve
and check all connections for leaks.
Run the water for at least 5 minutes
to remove any air and carbon
particles in the system.

12
Step 7.
Display & Reset:
After installing new filters push and hold the settings button for 3 seconds. Filter 1 icon will
blink. Push the reset button and hold for 3 seconds and the icon will reset to full capacity. Push
the settings button again and filter 2 icon will blink. Push and hold the reset button for 3
seconds and the icon will reset to full capacity. Push the settings button to exit the reset mode.
Flush:
When installing new filters, you must flush for a minimum of 10 minutes, the flush icon will blink
until done. If filters have not been used for more than 3 days, the flush icon will blink. Flush for
a minimum of 5 minutes.
Potable Water Icon:
The Potable Water icon will blink when the filter is ready for use.
! CAUTION - Do not drink the water before the Potable Water icon blinks.
Filter Icon:
The Filter Icon represents the 2 filters for the FF-1000 filter unit. Indication
of 5 bars show a new filter, 100% capacity, 4 bars 50-75%
capacity, 3 bars 25-50% capacity, 2 bars 5-25% capacity,
1 bar less than 5% capacity. When below a 5% capacity the Filter Icon
will blink, and the unit will buzz every 6 seconds when the water is flowing.
At 0% filter capacity the icon will blink constantly.
Battery Icon:
When the batteries reach below 10% capacity the
Battery Icon will blink and a warning light will come on.
Cleaning in Progress Icon:
The conditions that initiate the cleaning process are when the filter has not been used for three
days or after the filters are replaced. If any of the two conditions are met, the "cleaning" starts.
The "Cleaning in Process" icon starts to blink. The cleaning takes ten minutes. It stops blinking
after ten minutes when the cleaning is completed.
Potable Water
Replace Filter Soon
Cleaning in Progress
1
!
2
Filter Icon
0% Capacity
Battery Icon
Full
Battery
Low
Battery
Settings Button
Reset Button

13
Troubleshooting
If you have followed the instructions carefully and your faucet still does not work properly, take the following corrective steps:
Water leaks between the
filter head and the filter cartridge. An O-ring is damaged, dirty, or
out of place.
Turn off the water supply, and relieve
water pressure. Remove the filter
cartridge and inspect the O-rings for
damage or debris, and ensure that the
O-rings are in place. Reinstall the filter
cartridge, turn on the water supply, and
check for water leakage.
Water leaks at a threaded
connection.
The connection is
damaged or dirty.
Turn off the water supply, and relieve
water pressure. Disconnect the fitting, and
inspect the seal for damage or debris.
Remove any debris or replace the
damaged fitting. Securely reconnect the
fitting.
IMPORTANT - DO NOT overtighten.
Turn on the water supply and check for
leakage.
Water leaks at a tubing
connection.
Tubing is not cut square, or is
damaged or crimped.
Turn off the water supply, and relieve
water pressure. Remove the Quick Connect
Lock Tab. Press in the collar around
the fitting at the leak, and pull the tubing
to remove. Use a sharp utility knife to
cut 1/2″ (13 mm) off the end of the
tubing. Reinsert the tubing into the
fitting. Turn on the water supply and
check for leakage.
PROBLEM CAUSE ACTION

14
Replacement Parts
1. Quick Connect Lock Tab
2. Mounting Screws & Anchors
3. Tubing 1/4" x 8'
4. Tee Adapter
6. Polypropylene Cartridge
Replacement Parts List Part # Source
KP26063
KP26061
KP26062
KP26064
KF-1CB
KF-1PP
KP26069
5. Compressed Carbon Cartridge
1
2
3
4
5
6
This system has been tested according to NSF/ANSI 42, 53
and 401 for reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system as specific
in NSF/ANSI 42, 53 and 401.
DMT
Keruichuang & Shengfa
Zhongdenuo
Meigu
Filtertech
Filtertech
7
7. 3x AA Batteries* Regular compliance
* - Batteries provided with initial purchase only
Model: FS-1000/FS-1000-B
Replacement Filters: FC-100PP and FC-100CB
Requirement in Iowa - The seller shall retain the signed PDS on file at the seller’s place of business for at least
two years:
Buyer _____________________________________________________________ Date ________________________________
Seller _____________________________________________________________ Date ________________________________
Performance Data Sheet
Substance Influent Challenge Minimum % Reduction or Maximum
Concentration Product Water Concentration Requirement
chlorine
particulate, Class I particles 0.5 to <1 μm
lead
Bisphenol A
Phenytoin
Ibuprofen
Naproxen
Estrone
Nonylphenol
2.0 mg/L ± 10%
at least 10,000 particles/mL
0.15 mg/L ± 10%
2000 ng/L ± 20%
200 ng/L ± 20%
400 ng/L ± 20%
140 ng/L ± 20%
140 ng/L ± 20%
1,400 ng/L ± 20
≥ 50%
≥ 85%
0.005 mg/L
300 ng/L
30 ng/L
60 ng/L
20 ng/L
20 ng/L
200 ng/L
Chloroform (VOC Surrogate) 0.300 mg/L ± 10% ≥ 95%
PFOA (perfluorooctanoic acid CAS #335-67-1) 0.0015 mg/L ± 10% 0.00007 mg/L
PFOS (perfluorooctane sulfonate 0.0015 mg/L ± 10% 0.00007 mg/L
CAS #1763-23-1)
2
2
8
8. Battery Compartment Regular compliance

15
Performance Data Sheet
(based on VOC surrogate testing)
Substance Influent Challenge Minimum % Reduction or Maximum
Concentration mg/L Product Water Concentration Requirement mg/L
alachlor
atrazine
benzene
carbofuran
dibromochloropropane (DBCP)
chlorobenzene
chloropicrin
carbon tetrachloride
2,4-D
0.050
1,1-dichloroethylene
o-dichlorobenzene
p-dichlorobenzene
1,2-dichloroethane
cis-1,3-dichloropropylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
ethylene dibromide (EDB)
dinoseb
endrin
ethylbenzene
heptachlor epoxide
heptachlor
methoxychlor
hexachlorobutadiene
hexachlorocyclopentadiene
lindane
styrene
pentachlorophenol
simazine
2,4,5-TP (silvex)
1,1,2,2-tetrachloroethane
tetrachloroethylene
toluene
1,1,2-trichloroethane
tribromoacetic acid
1,2,4-trichlorobenzene
1,1,1-trichloroethane
trichloroethylene
xylenes (total)
trihalomethanes (includes)
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
haloacetonitriles (HAN)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
haloketones (HK)
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
0.001
0.100 0.003
0.081 0.001
0.190 0.001
0.078 0.0018
0.077 0.001
0.015 0.0002
0.110 0.0017
0.052 0.00002
0.080 0.001
0.040 0.001
0.088 0.0048
0.083 0.001
0.170 0.0005
0.086 0.001
0.080 0.001
0.079 0.001
0.170 0.0002
0.053 0.00059
0.088 0.001
0.044 0.00002
0.0072 0.0001
0.0082 0.0003
0.025 0.00001
0.0107 0.0002
0.044 0.001
0.060 0.000002
0.055
0.00010.050
0.0010.096
0.0040.120
0.00050.150
0.0010.081
0.0010.081
0.0016
0.078
0.001
0.270
0.0005
0.042
0.0046
0.160
0.0005
0.084
0.150
0.180 0.001
0.300 0.015
0.070 0.001
0.0096 0.0002
0.015 0.0003
0.022 0.0005
0.024 0.0006
0.001
0.00001

All-in-One Filtration Set - Limited Warranty
Kraus USA Plumbing, LLC extends this warranty to the original consumer and commercial purchasers of the All-in-One
Filtration Set (the “Product”) when purchased from an authorized Kraus dealer and in the location of original installation.
This warranty is non-transferable.
Kraus warrants the structure and finish of the Product to be free from defects in material and workmanship under normal
usage for a period of one (1) year from the date of purchase by a trade professional or end-user of the Product from an
authorized Kraus dealer.
Any product reported to the authorized dealer or to Kraus as being defective within the warranty period will be repaired
or replaced with a product of equal value at the option of Kraus.
Care Instructions
The filters must be replaced every six (6) months or when the 700 gallon capacity has been exceeded, whichever comes
first. You may also need to replace if you notice a decrease in water flow.
What is Not Covered
This warranty does not cover Products that were discontinued when purchased or display Products, whether such
Products were purchased at discount outlets, unauthorized dealers, and/or sold on clearance. This warranty does not
cover any free gifts included with purchase.
This warranty does not cover damage resulting from neglect, misuse (including use for an unintended application),
abuse, carelessness, accident, hard water or mineral deposits, exposure to corrosive materials, improper maintenance,
alteration of the Product, failure to follow care, cleaning or installation instructions enclosed with your Product. Kraus
recommends that all Kraus Products be installed by a fully licensed and insured trade professional with experience in the
installation of bathroom and/or kitchen manufactured goods.
Codes/Standards Applicable:
UPC
R
The system is certified by IAPMO R&T according to NSF/ANSI 42 standard for material safety, structural
integrity, chlorine, particulate I; NSF/ANSI 53 standard for Lead, VOC and PFOA/PFOS reduction; NSF/ANSI 401
standard for Bisphenol A, Phenytoin, Ibuprofen, Naproxen, Estrone, Nonylphenol and NSF/ANSI 372 for low
lead compliance. See Performance Data Sheet for individual contaminants and reduction performance.
System conforms to NSF/ANSI 42, 53, 401 and 372 for the specific performance claims as verified and
substantiated by test data.
While testing was performed under standard laboratory conditions, actual performance may vary.
R
16

How to Make a Warranty Claim
If you are a consumer purchaser, please contact a Kraus Customer Service Representative at:
Kraus USA Plumbing, LLC
12 Harbor Park Drive
Port Washington, NY 11050
Toll-free 800-775-0703
If you are a plumbing contractor or trade professional, please contact a Kraus Pro Representative at:
Kraus USA Plumbing, LLC
12 Harbor Park Drive
Port Washington, NY 11050
516-801-8955
If you are an authorized partner, please contact a Partner Support Representative at:
Kraus USA Plumbing, LLC
12 Harbor Park Drive
Port Washington, NY 11050
516-801-8954
In requesting warranty service, please be ready to provide your proof of purchase and a description of the problem.
Shipping charges will be covered for the first (1) year of the warranted replacement part or product (HI, AK, and Puerto
Rico shipping charges may apply). International shipping fees are not included.
Limitation on Duration of Implied Warranties
Please note that some states/provinces (including Quebec) do not allow limitations on how long an implied warranty
lasts, so the below limitations may not apply to you. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANY
IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE, IS LIMITED TO THE STATUTORY PERIOD OR THE DURATION OF THIS WARRANTY, WHICHEVER IS
SHORTER.
Limitation of Special, Incidental or Consequential Damages
Please note that some states/provinces (including Quebec) do not allow the exclusion or limitation of special, incidental
or consequential damages, so the below limitations and exclusions may not apply to you. TO THE MAXIMUM EXTENT
PERMITTED BY APPLICABLE LAW, THIS WARRANTY DOES NOT COVER, AND KRAUS USA PLUMBING, LLC SHALL NOT BE
LIABLE FOR, ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LABOR CHARGES TO REPAIR,
REPLACE, INSTALL OR REMOVE THIS PRODUCT), WHETHER ARISING OUT OF BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY, BREACH OF CONTRACT, TORT, OR OTHERWISE.
This warranty gives you specific legal rights, and you may also have other rights which vary from state/province to
state/province.
Download the Kraus Care & Maintenance Guide at:
http://www.kraususa.com/maintenance
R
17

Register Your Kraus Product
Activate Your Warranty
Access Premium Customer Support
Get Product Information
REGISTER TODAY
http://www.kraususa.com/registration
R
www.kraususa.com
IMPORTANT
This manual suits for next models
1
Table of contents
Other Kraus Water Filtration System manuals
Popular Water Filtration System manuals by other brands

GE
GE Profile PNRQ21LBN Owner's manual and installation

AquaSure
AquaSure Nano Ro user manual

PureEffect
PureEffect ULTRA-UC installation instructions

Filtreco
Filtreco Basic combi drum 25 user manual

OMOIKIRI
OMOIKIRI PURE DROP 2.1.4S manual

Microline
Microline T.F.C.-300 Installation, operation & service manual