manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. KROHNE
  6. •
  7. Measuring Instrument
  8. •
  9. KROHNE OPTISONIC 6300 F User manual

KROHNE OPTISONIC 6300 F User manual

For initial set up, we strongly recommend the use of the relevant manuals in addition!
System Configuration
2
100...230VAC (-15% / +10%), 22VA
Diameter range and rail versions 24VDC (-55% / +30%), 12W
Small
DN15...100 / 0.5...4" DN200...1250 / 8...50"
Small
Medium
DN50...400 / 2...16"
DN200...4000 / 8...160"
1
Sensor cable connections
2
I/O connections
3Mains supply connection
11/2021 - 4008317002 - OPTISONIC 6300 F/W R02 en 1 2
Ultrasonic clamp-on flowmeter for liquids
Installation, assembly, start-up and maintenance may only be performed by appropriately trained personnel.
Check the nameplate for correct operating conditions.
Quick Start
Quick Start
OPTISONIC 6300 F/W General Device nameplate
1 Electrical connection
For use in hazardous areas, special codes and regulations are applicable. Instruments must not be connected to
power supply before reading instructions described in the supplementary manual.
This instrument complies with requirements of Low Voltage Directive. Instruments must not be connected to
power supply before reading instructions described in the manual.
Check the device nameplate to ensure that the device is delivered
according to your order.
The responsibility as to the suitability, intended use and corrosion resistance of the used materials against the
measured fluid of this device rests solely with the operator.
All work on the electrical connections may only be carried out with the power disconnected. Take note of
the voltage data on the nameplate! Observe the national regulations for electrical installations!
Special conditions to be observed:
● For ambient and process temperatures, specific product and electrical data, see Ex manual or certificate
Observe without fail the local occupational health and safety regulations. Any work done on the electrical
components of the measuring device may only be carried out by properly trained specialists.
● The enclosures of the flow sensor and/or cable box shall be protected against electrostatic charging
Check the Ex data on nameplate in case of
an Ex version (if applicable)
Check for damage
● For dimensions and details of the flameproof joints, the manufacturer shall be contacted
● The tensile strength of the special fasteners is at least 700 N/mm² (property class A2-70 / A4-70) Electrical connections signal converter Power supply - grounding
● All connection cables are fixed and installed correctly so adequate protection against possible damage is
guaranteed 2 3
3
● Only for connection to a separately certified UFC 300 F/…Ex flow converter
● The instructions provided with the product shall be followed in detail to assure safe operation
1
Ex ► Type Examination Certificate: KIWA 17ATEX 0034 X / KIWA 18ATEX0007 X
Ta = -40…+70°C / -40…+158°F Medium The device must be grounded in accordance with
regulations in order to protect personnel against electric
shocks.
Tp = -40…+200°C / -40…+392°F
Maximum ambient and process temperatures
are depending on version (e.g liner material ,
DN size), temperature and protection class
and maximum surface temperature of sensor.
General
24VAC/DC (AC: -15% / +10%; DC: -25% / +30%),
22VA or 12W
Large
Refer to the manual for connection of Ex (/i ) acc. to
NAMUR
For devices used in hazardous areas, additional safety
notes apply; please refer to the Ex documentation.
1 2 3
Preferred measuring modes
1
2
3
1 2
3 4
5
4
11/2021 - 4008317002 - OPTISONIC 6300 F/W R02 en 3 4
120 °
General installation of the rails Greasing the transducer surfaces
 
2 Installation

Installation position
Change the position of the transducer
General configuration instructions
Pump, control valve - open feed / discharge
Check the manual for more details on installation options
(e.g. Large version installation or applying solid pads)
Go through menu X1...X5
Enter the values for the installation menu,
X1...X7.2.8
Read the advised mounting distance in menu
X7.2.3
The advised distance (menu X7.2.3)
must be > 246 mm / 9.7" for V-mode
Check the manual for more details on installation options
Choose the applicable measuring
mode Repeat if necessary.
Adjust settings in menu
X5 / X7 and finish with X7.2.9…7.2.11
Follow up with menu X7.2.4…X7.2.8
Run the optimization loop
Choose sensor size
Go through menu X1...X5
Measuring mode
Press > 2.5 s   
Measuring mode
Press > 2.5 s  
    1  
1shows when configuring a 2 pipe installation
11/2021 - 4008317002 - OPTISONIC 6300 F/W R02 en 5 6
3 Installation menu X 4 Quick Setup
Select menu Select Submenu Functions Status message
Tag number
X Installation X1 language Measured variable
X3.6 density
X3.7 temperature
X2 GDC IR interface
X3 units Signal strength
X3.1 size
X3.2 volume flow
Operating keys
X4 pipe configuration
select X4.1 number of pipes
X4.2 number of paths Select menu Select Submenu Functions
X3.3 free unit
X3.4 [m3/s]*factor
X3.5 velocity
X5 pipe data
X5.2 diameter 
X5.3 pipe material A
Quick Setup A1 Language
X5.4 VoS pipe material
A3.2 totalizer 1
X5.10 VoS fluid
X5.11 density A3.3 totalizer 2
A5.1 measurement
X7.2.11 end installation
Ready? or next transducer? /
install transd. 2 /
X8._ is identical to X7._
A5.2 pulse value unit
X5.12 glycol % vol.
X5.13 dynamic viscosity A3.4 totalizer 3
X5.14 pipe temperature
X5.5 wall thickness A2 Tag
X5.6 liner material
X5.7 VoS liner material
A3 Reset A3.1 reset errors
X5.8 liner thickness
X5.9 fluid
X7.2.2 number of traverses
X7.2.3 mount transducers at A4.3 range
X7.2.4 act. flow, prelim.
X6 if pipe=2 at X4.1 X6._: identical to X5._
A4 Analog Outputs A4.1 measurement
X7
install transd. 1
X7.1 transducer set
X7.2.1 calibration number A4.2 unit
X7.2.5 check signal A4.4 low fow cutoff
X7.2.6 actual distance
X7.2.7 optimize distance A4.5 time constant
X7.2.8 act.flow, prelim.
X7.2.9 path ready?
A5 Digital Outputs
X9
transducer sets
X9.1 Ta serial no. A5.1 value p. pulse
X9.2 Ta calibration no.
X9.3 Tb serial no. A5.1 low fow cutoff
X9.4 Tb calibration no.
X9.5 Tc serial no. A6 GDC IR interface
X9.6 Tc calibration no.

 



















Observe connection polarity
www.krohne.com
Pulse/frequency output active Pa (modular I/O) Control input active CN to NAMUR, (modular I/O)
11/2021 - 4008317002 - OPTISONIC 6300 F/W R02 en 7 8
Connection diagram Extension of signal cables
Large sensor rails
Current output passive Ip (basic I/O)
Small/medium sensor rail
Current output active Ia (basic I/O) Pulse/frequency output passive Pp (modular I/O)
Pulse/ frequency output passive PN, NAMUR (modular I/O)
Status output/limit switch passive Sp (basic I/O) Status output/limit switch passive Sp, (modular I/O)
(E/S de base)
Pulse/frequency output passive Pp (basic I/O) Status output/limit switch active Sa, (modular I/O)
Control input passive Cp (basic I/O) Status output/limit switch SN, NAMUR, (modular I/O)
Current output active Ia (modular/Ex i I/O) Control input active Ca, (modular I/O)
Download documents/software
Contact
Current output passive Ip (modular/Ex i I/O) Control input passive Cp, (modular/Ex i I/O) Scan the code on the nameplate or scan the
following code and enter the serial number.
Select your country from the region / language selector to view
your local KROHNE contact details on:

This manual suits for next models

1

Other KROHNE Measuring Instrument manuals

KROHNE OPTIFLEX 2200 C/F Wiring diagram

KROHNE

KROHNE OPTIFLEX 2200 C/F Wiring diagram

KROHNE OPTISWIRL 5080 Wiring diagram

KROHNE

KROHNE OPTISWIRL 5080 Wiring diagram

KROHNE VERSAFLOW SONIC 1000/TWS 9000 User manual

KROHNE

KROHNE VERSAFLOW SONIC 1000/TWS 9000 User manual

KROHNE 4000 Series User manual

KROHNE

KROHNE 4000 Series User manual

KROHNE H250 M10 Wiring diagram

KROHNE

KROHNE H250 M10 Wiring diagram

KROHNE OPTISWIRL 2100 Wiring diagram

KROHNE

KROHNE OPTISWIRL 2100 Wiring diagram

KROHNE UFM 3030 K EEx Series User manual

KROHNE

KROHNE UFM 3030 K EEx Series User manual

KROHNE AF-E 400 User manual

KROHNE

KROHNE AF-E 400 User manual

KROHNE OPTISWIRL 4200 Wiring diagram

KROHNE

KROHNE OPTISWIRL 4200 Wiring diagram

KROHNE OPTIBAR LC 1010 Wiring diagram

KROHNE

KROHNE OPTIBAR LC 1010 Wiring diagram

KROHNE OPTISYS SLM 2100 User manual

KROHNE

KROHNE OPTISYS SLM 2100 User manual

KROHNE OPTIWAVE 7300 C User manual

KROHNE

KROHNE OPTIWAVE 7300 C User manual

KROHNE OPTISWIRL 4200 Wiring diagram

KROHNE

KROHNE OPTISWIRL 4200 Wiring diagram

KROHNE WATERFLUX 3070 User manual

KROHNE

KROHNE WATERFLUX 3070 User manual

KROHNE OPTISWITCH 3000 C User manual

KROHNE

KROHNE OPTISWITCH 3000 C User manual

KROHNE DK37 Series User manual

KROHNE

KROHNE DK37 Series User manual

KROHNE OPTISYS CL 1100 User manual

KROHNE

KROHNE OPTISYS CL 1100 User manual

KROHNE OPTIWAVE 7300 C User manual

KROHNE

KROHNE OPTIWAVE 7300 C User manual

KROHNE OPTIPROBE User manual

KROHNE

KROHNE OPTIPROBE User manual

KROHNE BATCHFLUX 3100 User manual

KROHNE

KROHNE BATCHFLUX 3100 User manual

KROHNE OPTIMASS 3400 User manual

KROHNE

KROHNE OPTIMASS 3400 User manual

KROHNE OPTISYS TUR 1060 User manual

KROHNE

KROHNE OPTISYS TUR 1060 User manual

KROHNE OPTISWIRL 4070 User manual

KROHNE

KROHNE OPTISWIRL 4070 User manual

KROHNE Optisonic 6300 P User manual

KROHNE

KROHNE Optisonic 6300 P User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics ICP YJM320C15 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP YJM320C15 Installation and operating manual

Amprobe TACH-10 user manual

Amprobe

Amprobe TACH-10 user manual

CARLO GAVAZZI UDM 35 - PROGRAMMING Programming guide

CARLO GAVAZZI

CARLO GAVAZZI UDM 35 - PROGRAMMING Programming guide

SUPMEA SUP-5000C user manual

SUPMEA

SUPMEA SUP-5000C user manual

Grandway FHO1000 user manual

Grandway

Grandway FHO1000 user manual

Extech Instruments CO200 user manual

Extech Instruments

Extech Instruments CO200 user manual

TA AR-G2 Getting started guide

TA

TA AR-G2 Getting started guide

Hanna Instruments HI 38022 instruction manual

Hanna Instruments

Hanna Instruments HI 38022 instruction manual

janitza UMG 804 installation manual

janitza

janitza UMG 804 installation manual

SENSIT Technologies GOLD 100 Quick start instructions

SENSIT Technologies

SENSIT Technologies GOLD 100 Quick start instructions

PASCO OS-7053 manual

PASCO

PASCO OS-7053 manual

Burster 24508 Operation manual

Burster

Burster 24508 Operation manual

SKF MicroVibe P CMVL 3860-ML user manual

SKF

SKF MicroVibe P CMVL 3860-ML user manual

Grundfos DIT-M Installation and operating instructions

Grundfos

Grundfos DIT-M Installation and operating instructions

Enerpac GA-1 instruction sheet

Enerpac

Enerpac GA-1 instruction sheet

BAFANG DP C171.CAN user manual

BAFANG

BAFANG DP C171.CAN user manual

Greystone Energy Systems CR3 Series installation instructions

Greystone Energy Systems

Greystone Energy Systems CR3 Series installation instructions

Yamaha 6Y8- 2819U-00 owner's manual

Yamaha

Yamaha 6Y8- 2819U-00 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.