2.7.2 With electronics P (Profibus PA), F (Foundation Fieldbus)
The metallic parts of OPTIBAR * 5060 VGK5/6/D*A/W/V E/Z/6/7 are electrically connected with
the ground terminals.
The supply and signal circuit is reliably isolated from parts which can be grounded by a galvanic
isolation.
2.7.3 With electronics S or T for electronic differential pressure measurement
The metallic parts of OPTIBAR * 5060 VGK5/6/D*A/W/V E/Z/6/7 are electrically connected with
the ground terminals.
The supply and signal circuit is reliably isolated from parts which can be grounded by a galvanic
isolation.
OPTIBAR * 5060 VGK5/6/D*A/W/V E/Z/6/7 with electronics P (Profibus PA), F (Foundation
Fieldbus), version with single chamber housing A, V
Supply and signal circuit:
(Terminals 1[+], 2[-] in electronics
compartment)
•Ui = 9...32 VDC
•Um = 253 VAC
Display and adjustment circuits:
(terminals 5, 6, 7, 8) For connection of an OPTIBAR * 5060 in protection type
flameproof enclosure "Ex db ia" with integrated electronics S
or T as electronic differential pressure measurement.
Circuit for the display and adjustment
module: (spring contacts in the
electronics compartment)
For connection to the display and adjustment module.
Table 2-8: Electrical data for OPTIBAR * 5060 with electronics P, F, version with single chamber housing A, V
OPTIBAR * 5060 VGK5/6/D*A/W/V E/Z/6/7 with electronics P (Profibus PA), F (Foundation
Fieldbus), version with double chamber housing D, W
Supply and signal circuit:
(Terminals 1[+], 2[-] in terminal
compartment
•Ui = 9...32 VDC
•Um = 253 VAC
Display and adjustment circuits:
(terminals 5, 6, 7, 8) For connection of an OPTIBAR * 5060 in protection type
flameproof enclosure "Ex db ia" with integrated electronics S
or T as electronic differential pressure measurement.
Circuit for the display and adjustment
module: (spring contacts in the
electronics compartment)
For connection to the display and adjustment module.
Table 2-9: Electrical data for OPTIBAR * 5060 with electronics P, F, version with double chamber housing D, W
OPTIBAR * 5060 VGK5/6/D*A/W/V E/Z/6/7 with electronics S or T
Supply and signal circuit:
(Terminals 5,6,7,8 in electronics
compartment)
For connection to an
OPTIBAR * 5060 VGK5/6/D*A/W/V E with integrated
electronics H (4…20 mA/HART®), A (4…20 mA/HART® with SIL
qualification), P (Profibus PA), F (Foundation Fieldbus) for
electronic differential pressure measurement
Table 2-10: Electrical data for OPTIBAR * 5060 with electronics S, T