COMMISSIONING / OPERATION
4
11
OPTIFLEX 2200 C/F
www.krohne.com11/2015 - 4003066803 - MA OPTIFLEX2200C-PA-R03-en-
Station address: DIP switch positions
The station address is calculated by adding the "ON" values of each switch on the DIP switch
block. The default setting for each switch is “OFF”.
If you change the DIP swtich positions, start the device again to use the new settings. If you use
the "Set_Slave_Add" service or "FACTORY_RESET code 2712" (reset station address to its
default value) to change the station address, it is not necessary to start the device again to use
the new settings.
Station address
•If the "Station Address" DIP switches are set to a correct station address (≤125) and the
"Hardware" DIP switch is set to "ON", the device uses the DIP switch setting as the station
address. The Set-Slave_Add service is ignored in this mode. The Set_Slave_Add service is not
available for Automatic Ident. Number adaptation at this time. Physical block parameter
FACTORY_RESET code 2712 is rejected.
•If the "Hardware" DIP switch is set to "OFF", the device does not use the new setting. If the
"Station Address" DIP switches are set to an incorrect address (>125) and the "Hardware"
DIP switch is set to "OFF", the device does not use the new setting. The Set_Slave_Add
service or the Physical block parameter FACTORY_RESET code 2712 (reset station address to
its default value) can be used to change the station address and for Automatic Ident. Number
adaptation. The Physical block parameter FACTORY_RESET code 2712 can also be used to
change the station address.
•If the "Station Address" DIP switches are changed from an incorrect address to a correct
address and the Hardware" DIP switch is set to "ON", the device uses the "Station Address"
DIP switch setting.
•If the the "Hardware" DIP switch is set to "OFF", the device will use the last correct setting for
this mode. If the "Station Address" DIP switches are changed from a correct address to an
incorrect address and the "Hardware" DIP switch is set to "OFF", the device will use the last
correct setting for this mode. If there is no station address set at this time, the device will use
the default address 126.
Function Bit DIP switch positions
Value ("OFF") Value ("ON")
Hardware 1 7OFF ON
Station address 6+ 0 + 64
5+ 0 + 32
4+ 0 + 16
3+ 0 + 8
2+ 0 + 4
1+ 0 + 2
0+ 0 + 1
1If this DIP switch is set to "ON", you cannot use the network bus to change the station address
INFORMATION!
You can also use the local display (menu item 2.6.1 ADDRESS) to set the Station Address to a
new value. You can change the value when the Hardware DIP switch is "OFF". If the Hardware
DIP switch is "ON", you can see the Station Address on the local display screen but you cannot
change the value.