manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. KSR
  6. •
  7. Lighting Equipment
  8. •
  9. KSR KSR9846 Assembly instructions

KSR KSR9846 Assembly instructions

Drg No. KSR9846-IS-D
28.11.2022-PJL
Installation Sheet KSR9846
Available finish:- White Finish
Remove the LED diffuser section to expost the insdide of the main body.
Remove one of the 20mm knock out from one end of the LED Batten, where possible select the
knock out closest to the terminal block inside the batten.
Remove the locknut from the KSR9846 and keeo safe.
Thread the three cables from the sensor through the knock out and into the batten.
Insert the threaded section into the knock out, slide the locknut over the cables and secure it to
the thread on the sensor housing.
Dress the three cables along the inside of the batten, connect the cables to the terminal block as
show opersite/below.
Black wire from sensor to Live In on the terminal block
Brown wire from sensor to your mains 240v input (use empty terminal for this connection)
Blue wire from sensor to Neutral on the terminal block
Using the guide below, set up the sensor to the desired time, range and lux level. Turn on the
power and test the luminaire.
LEDs are an inductive load so avoid unwanted MCB tripping it may be necessary to uprate your
breakers to a C type.
IP20 240VAC~50Hz 400W Max Load
Sensor Wires Luminaire/Mains Input
- Green/Yellow
Live Out - Black
N - Blue (Mains input and to LED Driver)Neutral - Blue
L - Brown (Mains 240v Input)
Live In - Brown
67
L - Brown (To Driver Input)
85
20
These fittings are Class II and do not reqruire an Earth
Important Information
It is recommended that these luminaires are installed and fitted by a qualified electrician
ensuring the installation complies with current IEE wiring regulations & local building
control. These products are designed for connection to a 240V~50Hz supply.
Any faulty, broken or damaged luminaires should be replaced immediately.
KSR will not accept responsibility for any claims arising from a poor installation.
Please Note: The limited warranty shall be deemed null and void in the following circumstances: Failure by the installer, end user or
any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal
operating ambient temperature -10 - +35°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as
failure related to workmanship in the installation of the products or parts.
Important User Advice
Always switch off mains supply before servicing.
This luminaire is suitable for indoor use only and should not be fitted to damp or wet
surfaces such as freshly plastered or painted walls.
Do not use Megger or similar high voltage instruments. Due to the fact this luminaire contains electronic components that maybe
damaged by high test voltages, they must be disconnected from the circuit before testing.
To prevent damage to the driver, do not mix with conventional magnetic ballasts on the same electrical circuit.
At the end of life the luminaire is classed as WEEE under directive 2014/30/EU and should be disposed of in accordance with local
legislation
Installation Procedure
Familiarize yourself with the luminaire/installation procedure and ensure the power is safely isolated before installing the luminaire.
Navara LED Batten Sensor
KSR Lighting Aftersales: 023 92 674343
E-mail: [email protected]
Read these instructions before commencing installation. Please give these instructions to the
owner/occupier after installation to retain for future reference/maintainence.
KSR Lighting Ltd, Optimum House, Beeding Close, Southern Cross Trading Estate,
Bognor Regis, West Sussex, PO22 9TS.
Drg No. KSR9846-IS-D
28.11.2022-PJL
KSR9846
1 - Detection Area
Detection area can be reduced by selecting
the combination on the Dip Switches,
following the guide as shown here.
2 - Hold Time
Hold time means the time period you would
like the light to remiain 'on' once no movement
is detected.
3 - Daylight Sensor
The daylight sensor can be set to bring the
light 'on' at specific daylight levels. To have
the sensor function in daylight set the Dip
Switches to Disable.
Installation Sheet
Read these instructions before commencing installation. Please give these instructions to the
owner/occupier after installation to retain for future reference/maintainence.
Issue Cause Solution
The load will
not illuminate
Incorrect daylight threshold
setting selected
Adjust setting and
retest
Load has failed
(driver or LED array) Replace load
No mains power detected Switch on power
The load is
permanently
illuminated
Continuous movement in
the detection area
The lamp (containing sensor)
is installed in an area too close
to reflective surface, i.e Metal,
Glass or Concrete walls.
Check detection area setting
Make sure installation area suitable
with at least 30cm space
between lamp and surrounding
reflective surfaces
Reduce Sensitivity (detection area)
1.
2.
The load will not
illuminate despite
movement
Speed of moving object is not
in the range of 0.5-3m/s or the
detection radius is too small
Check Detection area setting
This Microwave sensor is a motion activated switch, it will turn the light on when
movement is detected, then hold the light on for the determined amount of
time, after which the light will turn off.
Using the Dip Switches on the sensor, set it up to your preferred Detection area,
Hold Time & Daylight level.
Microwave sensors will detect movement through certain materials, if this occurs
reduce the detection area until any nuisance triggering stops.
Max Load - 400W (Inductive)(LEDs)
Max Load - 800W (Resistive)
Troubleshooting
The Sensor is designed for installation heights of 3-6m
Recommended Installation heights
For Wall mounting the height is 1.5m
For Ceiling mounting the height is 3m
Navara LED Batten Sensor
IP20 240VAC~50Hz 400W Max
KSR Lighting Ltd, Optimum House, Beeding Close, Southern Cross Trading Estate,
Bognor Regis, West Sussex, PO22 9TS.

Other KSR Lighting Equipment manuals

KSR Siena CL KSR5311 Assembly instructions

KSR

KSR Siena CL KSR5311 Assembly instructions

KSR KSRSF333 Assembly instructions

KSR

KSR KSRSF333 Assembly instructions

KSR KSR98202 Assembly instructions

KSR

KSR KSR98202 Assembly instructions

KSR Navara SF Select Assembly instructions

KSR

KSR Navara SF Select Assembly instructions

KSR KSR98200 Assembly instructions

KSR

KSR KSR98200 Assembly instructions

KSR Navara HBX Assembly instructions

KSR

KSR Navara HBX Assembly instructions

Popular Lighting Equipment manuals by other brands

Federal Signal Corporation VISTA 581016-OHP Series Installation and maintenance instructions

Federal Signal Corporation

Federal Signal Corporation VISTA 581016-OHP Series Installation and maintenance instructions

Poolweb AQWC101520A-V01 instruction manual

Poolweb

Poolweb AQWC101520A-V01 instruction manual

IOTA ILB-CP Series instruction manual

IOTA

IOTA ILB-CP Series instruction manual

B-K lighting LT installation instructions

B-K lighting

B-K lighting LT installation instructions

SLV Elektronik 229874 instruction manual

SLV Elektronik

SLV Elektronik 229874 instruction manual

Vision & Control R-CLR-100x73-G523-SL Installation and operating instructions

Vision & Control

Vision & Control R-CLR-100x73-G523-SL Installation and operating instructions

Lumination tradeSELECT LUMELSQ Series quick start guide

Lumination

Lumination tradeSELECT LUMELSQ Series quick start guide

FLOS OK F4640030 Assembly

FLOS

FLOS OK F4640030 Assembly

Flash LASER 1000mW RGB II ev. user manual

Flash

Flash LASER 1000mW RGB II ev. user manual

thomann Stage TRI LED Bundle Complete user manual

thomann

thomann Stage TRI LED Bundle Complete user manual

Magnum Mx-UTR-L3 installation guide

Magnum

Magnum Mx-UTR-L3 installation guide

luminii Teava Suspension TEA-S Series installation instructions

luminii

luminii Teava Suspension TEA-S Series installation instructions

Soundoff Signal nFUSE manual

Soundoff Signal

Soundoff Signal nFUSE manual

Alkalite VBAR 270 user manual

Alkalite

Alkalite VBAR 270 user manual

Utilitech Pro UC1051-AL3-09LF0-U manual

Utilitech Pro

Utilitech Pro UC1051-AL3-09LF0-U manual

Lightforce STRIKER IR User instructions

Lightforce

Lightforce STRIKER IR User instructions

Wetekom 82 42 76 instruction manual

Wetekom

Wetekom 82 42 76 instruction manual

Beamz Pro Starcolor 54 user manual

Beamz Pro

Beamz Pro Starcolor 54 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.