RELATIVE ZERO rMODE
Relative Zero rmode allows the user to offset the
meter consecutive measurements with the displaying
reading as the reference value. The display will now
show readings relative to the stored reference value.
That is, display= reading - stored value. Press the r
button momentarily to toggle to the relative zero
mode. The annunciator “r“ turns on. The meter
also enters manual ranging mode where available.
The annunciator turns off.
MANUAL OR AUTO-RANGING
Press the RANGE button momentarily to select
manual -ranging mode, and the meter will remain in
the range it was in, the LCD annunciator
turns off. Press the button momentarily again to step
through the ranges. Press and hold the button for 1
second or more to resume auto-ranging mode.
Display Backlight (available in 2754A-T only)
Press the SELECT button for 1 second or more to
toggle the display backlight on and off.
AUTO POWER OFF (APO)
When the meter is on, the Auto Power Off (APO)
feature will switch the meter to sleep mode
automatically after approximately 30 minutes of no
slide-switch nor push button operations to extend
battery life. To wake up the meter from APO, press
any push-buttons momentarily or set the slide-switch
to the OFF position and then slide back on again.
Always set the slide-switch to the OFF position
manually when the meter is not in use.
“AUTO”
“AUTO”
17
MAINTENANCE
WARNING
To avoid electrical shock, disconnect the meter from
any circuit, remove the test leads from the input jacks
and turn OFF the meter before opening the case. Do
not operate with open case.
Trouble Shooting
If the instrument fails to operate, check batteries
and test leads etc., and replace as necessary. Double
check operating procedure as described in this user’s
manual.
If the instrument voltage-resistance input terminal
has subjected to high voltage transient (caused by
lighting or switching surge to the system) by accident
or abnormal conditions of operation, the series fusible
resistors will be blown off (become high impedance)
like fuses to protect the user and the instrument. Most
measuring functions through this terminal will then be
open circuit. The series fusible resistors and the
spark gaps should then be replaced by qualified
technician. Refer to the Warranty section for
obtaining warranty and repairing service.
Cleaning and storage
Periodically wipe the case with a damp cloth and mild
detergent; do not use abrasives or solvents. If the
meter is not to be used for periods of longer than 60
days, remove the batteries and store it separately.
!