Kyoto Kagaku MW29 User manual

MW29
Donotmarkonthemodelandother
componentswithpennorleaveprinted
materialscontactedonsurface.
Inkmarksonthemodelscannotbe
removed.
Caution
OralCareSimulatorAdvanced
Contents
●BeforeYouStar
SetIncludes
ManufacturerʼsNotes
●
●TrainingSession
●AfterTraining
OralCare
Suction
Preparation
P.2
P.3
P.11〜P.12
P.6〜P.7
P.3〜P.4
P.8〜P.10
P.10
● Introduction
P.1
P.5
CheckingtheConnections
SettinguptheHeadManikin
ChangingDentures
SettingofPatientConditions
Instruction
Manual


1
ManufacturerʼsNoteIntroduction
Besurenottodroporaddshocktothemanikin
anditscomponents,sincetheproductuses
specialresinsandheavy,suchshockmaycause
damagetotheproductsorenvironment.
Handlethemanikinandthecomponents
withcare.
Neveruseorganicsolventlikepaint
thinnertocleantheskin,asthiswill
damagethesimulator.
●
●
●
●
●
●
●
●Useclearwaterfortraining.
Donotuserealantisepticormedicineasitmay
stainintraoralcavityandabsorbedcolorwill
becomeirremovable.
Donotletinkfrompens,newspapers,
thismanualorothersourcescontactwith
themanikin,astheycannotbecleanedoff
themanikinskin.
Storageinadark,coolanddryspacewill
helppreventtheskincolorsfromfading
andproductfromdeforming
Constituentinthesimulatedresiduemay
separate.
Attimessomeconstituentinthesimulatedresidue,
suchasalcoholmaybeobserved,thoughthisdoes
notaffectthequalityandperformanceofthe
product.
Themanikinskinmaybecleanedwith
awetclothifnecessary,usingmildly
soapywaterordiluteddetergent.
Evenifcoloronitssurfacemightbe
changedacrosstheages,thisdoesnot
affectthequalityofitsperformance.
MW29OralCareSimulatorAdvancedisdesignedfortrainingofhealthcare
professionalstoacquireskillsintakingcareofpatientsʼoralhygiene.
Usageforanyotherpurposeorthewayofusenotdescribedinthismanualis
stronglydiscouraged.
Features
-Anatomicallycorrectoralcavity,trachea,esophagusandreplaceabledentures,
-Twovariationsofdentures:normal(healthy)andteethwithdisease
-Avarietyofpatientpositioning
-Trainingwithrealwater
DOsandDONʼTs

aaa
2
a
b
c
d
e
fg h i
j
BeforeYouStart SetIncludes
SetIncludes
Beforeyoustart,ensurethatyouhaveallcomponentslistedbelow.
Sponge-tippedswabs
1
1
1
2
1
1
1
1
a.
b.
c.
g.
h.
i.
f.
d.
e.
1
Head/neckmanikin
*Simulatedresidueisconsumable.
Base
Normaldenture
Denturewithtoothdisease
Simulatedresidue
Mirror
Toothbrush
Denturebrush
j. Casefordenture 1
Instructionmanual

3
1
Preparation CheckingtheConnections
SettinguptheHeadManikin
CheckingtheConnections
1.
Takeoutthehead/neckmanikinandthebasefromthe
carryingbag.Thehead/neckandbaseisassembledat
the time of delivery. Verify that two mini bottles for
tracheaandoneminibottlefortheesophagusarefirmly
attached.
1.Removethesealsonthesuctioncapsunderthebase.
2.Selecttheplacewheretosettheheadmanikinandputitthere.Pressdownthesuctioncupat
theheadsideontothetabletop.Thenturnthetwodialsatthenecksideclockwisetoanchor.
○Tabletoptraining.(Prepareatablewithsmoothsurface.)
[SecuringtheHead/NeckManikin]
3. Todisengage,releasethesuctioncupattheheadsidebyliftinguptheplatewithfinger,
andthenturnthedialscounterclockwisetoreleaseremainingsuctioncups.
*
2SettinguptheHeadManikin
Dirtanddustonthe
surfaceof
thesuctioning
cupsweakentheirhold-
ingpower.
Cleantheirsurfacebefore
setting-up.

[Positioning]
4
○Tabletoptraining
2
Preparation Setting-up
Preparation
1.TosetthemanikinatFowlerʼspositionorsittingposition,putapilloworatoweltosecure
theheadindesiredplace.
Spine Fowlerʼs Sitting
2.Rotatetheheadtoleftorrighttoadjusttheposition.
1
.
Putthemanikinonthebadandadjustthebedʼsangle.
Supportthemanikinsecurelyinplacebyapilloworbyanassistantwhennecessary.
○Trainingonthebed.
Caution Torotatethehead,besureto
holdtheheadwithbothhand.
Becarefulnottoholdtheneck
area, so as not to pinch the
fingers.

5
3
Preparation SettingupandRemovingDentures
ChangingDentures
[Setting-upDentures]
Thesetincludesnormaldenturesanddentureswith
toothdisease.Selectthepartsaccordingtotraining
scenario.
Dentures(Normal) ToothDisease
1.Toattachthedenture,fitthegrooveatthebacktotheteethtothegumandpressthedenture.
Whensettingtheupperdenture,firstfixthefrontteethandthenfitthebackteeth.
Toattachthelowerdenture,firstputthedentureinplacetosurroundthetongue,thenpressdown
thefrontteethandfinallyfitandpressthebackteeth.
Caution
2.
Toremovethedentures,firstliftand
disengagethebackteeth.
[Removal]
Becarefulnottocatchthemanikinʼstongueunderthedenture.
Donotlubricatethesurfaceofthedenturesasitmakesremoval
ofdenturesdifficult.

6
4
Preparation SettingofPatientConditions
SettingofPatientConditions
[PatientwithEndotrachealTube]
1.Besuretocoatthetubewithlubricant.
Insufficientlubricationmaycausechallengesininsertionofthetube.
Placetheendotrachealtubeinthemanikinʼsairwaytosimulate
apatientsreceivingventilation.
**Recommendedsizeonendotrachealtube:internaldiameter7.0mm
*BesuretouseauthenticKyotoKagakulubricant.
Trainingofintubationisnotintended.Theendtrachealtube
canbesetbyhandwithoutusingthelaryngoscopeorstylet.
2.
Removethedentures.Insertthefingerintothemanikinʼs
oralcavityandfeeltolocatetheglottis.
3.Inserttheendotrachealtubeintotheairway.Insert
thetipofthetubeintotheglottisbythefinger.
4.Holdingthetubewiththefinger,insertthetube
intotheairway.
OralCavity
Tangue Glottis
EndotrachealTube
[SecuringtheTube]
Thetubecanbesecuredusingadhesivemedicaltapes.
Recommendedtaps
:3MTMMultiporeDrySurgicalTapeTM.
Donotleavethemanikinwithtapesadhered
onitsskin.Theadhesivematerialsmaybe
absorbedbyskinandmakeitsticky.
Caution
Note

7
1.Lubricatethecatheterrouteandthetubewell.Insufficientlubricationmaymaketheinsertionchallenging.
4SettingofthePatientConditions
*Recommendedcathetersize:14fr.
Cap
plug
Preparation SettingthePatientConditions
[Patientreceivingtubefeeding]
Placingafeedingtubeinnasalororalroutetosimulateapatientwithtubefeeding.
[Patientwithtracheostomy]
Placethecannulatothetracheostomyopeningtosimulateapatientwithtracheostomyventilation.
1.Removetheplugforthetracheostomyopening.Lubricatethetubeandtheinsideoftrachea.
*Sincethetracheostomyopeningisalreadymade,attimessometypesorsizesofcannulamaynotfitwell.
TracheostomyTubeII(internaldiameter8.0mm,externaldiameter11.0mm)isavailableasanoptionalpart.
Caution
BesuretousetheauthenticKyotoKagaku
lubricantfortraining,whichisavailableasan
optionalpart.Donotusegeltypelubricantas
itssubstancedriesandremaininthemanikin.
Sometimes,thecapofthe
TracheostomyTubeIImaycome
offduetolubricationandleftin
theairway.Whenitoccurswipe
offthelubricantand/orwater
bothfromthecapandinsideof
thetipofthecannulaandthen
replacethecap.

8
1
FoodResidue
Coatedtongue
Spacedarch
Isolatedtooth
Stomatitis
Missingteeth
Rootfracture
[ObservationoftheOralCavity]
OralCare
TrainingSession OralCare
[ObservationoftheOralCavity]
1.Setthedenturewithtoothdiseasetoperformobservationoftheoralcavity.
○ Apatientwithteeth/oralproblems
NormalToothDisease
*Applythesimulatedresidue
Atoothwithout
neighboringteeth
*Applythesimulatedresidue
Stumpofatooth
Astumpwithout
dentalcrown
Crowding
GingivalRecession
Non-DentalProblem
DentalProblem
DentalandOralProblems
2.
Applythesimulatedresidueontheteethand/orthetonguetoperformobservation.
○Observationoffoodresidueandcoatedtongue.
Whenevernotinuse,ensuretoclosethecapofthetubeofthesimulatedresiduetoprevent
drying.
Caution

9
1
OralCare
TrainingSession OralCare
[CleaningoftheOralCavity]
1.Settheheadmanikintosimulatepositionsofpatientswithdifferentdegreeofrequirementsfor
assistance.Setinstrumentstosimulatepatientsundermedicalintervention.Applythesimulated
residuetopracticebrushingandcleaning.
2.
1.
[CareoftheDentures]
Donotusetoothpasteasitmay
damagetheparts.
Caution
Afterbrushingandcleaning,applywater(washfluid)totheoralcavityandcleanwhilesuction-
ingexcessliquid.Incasethatthesuctioningisunsuccessful,excessliquidflowsintothemini
bottlestoindicatethatliquidflowsintobronchioresophagus.
Practicehowtoremoveandattachdenturesas
wellashowtocleanthedenturesusingthe
denturebrush.

[Massaging]
10
1.Practicehowtoperformsalivaryglandsmassagetostimulatesecretion.
1
2
TrainingSession OralCare
Suction
[RemovalofTongueCoating]
1. Applythesimulatedresidueonthetongue
topracticecleaningusingaspongebrush
oratonguebrush.
OralCare
ParotidGland SubmaxillaryGland SublingualGland
1. Proceduresofnasal,oralandtracheostomysuctioncanbesimulated.
[Suctioning]
Suction

11
3.Removetheminibottlesbyturningclock-wise.Thenwashanddrythebottles.
1
Becarefulnottomisplacethescrews.
AfterTraining
AfterTraining
1.Removeallmedicalinstruments,medicaltape
andthedentures(seepage.5).
Incasethatthesimulatedresidueisused,
removeitcompletelyanddrythepartswell.
2.
Removethetwoscrewswhichconnecttheheadmanikinandthebasebyturningcounter-clockwise.
Thenremovetheheadmanikinfromthebase.
Note

AfterTraining
12
5. Replacethemini-bottleandthebottle.
6.Assembletheheadmanikinandthebaseandfixthemtogetherwithtwoscrews.Turnthescrew
clockwisetofasten.Thenreplacetheplugtothetracheostomyopening.
7.
Storetheassembledheadinthestoragebag.
1
4. Removetheplugfortracheostomyopening.Washinsidewithrunningwater.Thendrytheparts
well
AfterTraining


2018.01
Donotmarkonthemodelandothercomponentswithpennorleaveprintedmaterialscontactedonsurface.
Inkmarksonthemodelscannotberemoved.
Forinquiriesandservice,pleasecontactyourdistributororKYOTOKAGAKUCO.,LTD.
11408-010
11408-020
11408-030
PartName
simulatedresidue
SimulatedResidue
normaldenture
NormalDenture
DenturewithToothDisease
denturewithtoothdisease
11229-050
12746-020
PartName
lubricantfortrainingmodel
tracheostomytubeⅡ
LubricantforTrainingModel TracheostomyTubeII
Consumables
Optional
Parts
Caution
Thecontentsoftheinstructionmanualaresubjecttochangewithoutpriornotice.
Nopartofthisinstructionmanualmaybereproducedortransmittedinanyformwithoutpermissionfromthemanufacturer.
Pleasecontactmanufacturerforextracopiesofthismanualwhichmaycontainimportantupdatesandrevisions.
Pleasecontactmanufacturerwithanydiscrepanciesinthismanualorproductfeedback.Yourcooperationisgreatlyappreciated.
■■ (WorldWide)
Kyoto Kagaku America Inc.
MainOfficeandFactories Americas
Table of contents
Other Kyoto Kagaku Fitness Equipment manuals
Popular Fitness Equipment manuals by other brands

Energetics
Energetics BB 10 Assembly manual

ICON Health & Fitness
ICON Health & Fitness NordicTrack Vault user manual

HOMCOM
HOMCOM A90-289 Assembly & instruction manual

Crivit
Crivit MR-1442 Instructions for use

Weider
Weider Redline2 Upright Bench manual

Pulse fitness
Pulse fitness 240G Assembly, Operation & Parts Manual