La Proromance HSS-A User manual

PATIO HEATER HSS-A
USER MANUAL

2
Dear customer,
Thank you for purchasing our product. Please read the following instructions carefully
before using for the first time and keep this user manual for future reference. Pay
particular attention to the safety instructions. If you have any questions or comments
about the device, please contact the customer line. Customer line, availability 24 hours a
day: +44 (0)203 514 4411, www.alza.co.uk.
Importer: Alza.cz a.s. Jankovcova 1522/53, Holešovice 170 00 Prague 7 www.alza.cz
SAFETY WARNINGS
Read these safety rules before operating the product!
If you smell gas:
•Shut off the gas in the appliance.
•Extinguish any open flame.
•If the odor persists, contact your gas supplier or fire department immediately.
For your safety:
1) Do not store or use gasoline or other flammable liquids and vapors near this or
any other equipment.
2) An LP bottle that is not connected for use must not be stored near this or any
other device.
WARNING
1) The product is intended for use outdoors or in well-ventilated areas.
2) A sufficiently ventilated area is one where at least 25% of the area is open and
ventilated.
3) The surface area is the sum of the wall surfaces.
Improper installation, adjustment, modification, service, or maintenance can
cause injury or property damage. Read the installation, operation, and
maintenance instructions carefully before installing or servicing this equipment.

3
Read the following instructions before installation and use
•This appliance must be installed and the gas cylinder must be stored in
accordance with the applicable regulations.
•Do not cover the ventilation holes of the cylinder housing.
•Do not move the device while it is in operation.
•Close the valve on the gas cylinder or regulator before moving the appliance.
•The tubing or the flexible hose must be changed within the prescribed intervals.
•Use only the type of gas and the type of cylinder specified by the manufacturer.
•The LP tank used with the heater must meet the following requirements:
oBuy LP tanks only with the following required dimensions:
▪(31.8 cm) (diameter) × (58 cm) (height) with a maximum capacity of
15 kg.
•In case of strong wind, special attention must be paid to tilting the device. Keep
the appliance at least 1 m away from the gas cylinder.
•The injector in this device is not removable and the injector is only installed by
the manufacturer. It is forbidden to convert from one gas pressure to another in
this device.
•Do not connect the gas cylinder directly to the appliance without the regulator.
Use only the type of gas and type of cylinder specified in the instructions.
Regulator (compliant with EN16129: 2013 and national regulations) with the correct
pressure corresponding to the appliance category.
Use a 30mbar regulator for butane / propane under the category I3B/P(30).
It's recommended to use flexible hose that approved by EN16436.

4
WARNING
PLEASE READ THE FOLLOWING SAFETY GUIDELINES CAREFULLY BEFORE
OPERATION.
•Do not use the patio heater for indoors, as it may cause personal injury or
property damage.
•This outdoor heater is not intended to be installed on recreational vehicles
and/or boats.
•Installation and repair should be done by a qualified service person.
•Improper installation, adjustment, alteration can cause personal injury or
property damage.
•Do not attempt to alter the unit in any manner.
•Never replace or substitute the regulator with any regulator other than the
factory-suggested replacement.
•Do not store or use gasoline or other flammable vapors or liquids in the heater
unit.
•The whole gas system, hose, regulator, pilot or burner should be inspected for
leaks or damage before use, and at least annually by a qualified service person.
•All leak tests should be done with a soap solution. Never use an open flame to
check for leaks.
•Do not use the heater until all connections have been leak tested.
•Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve
OFF. If the leak is at the Hose/Regulator connection: tighten connection and
perform another leak test. If bubbles continue appearing, the product should be
returned to hose’s place of purchase. If the leak is at the Regulator/Cylinder Valve
connection: disconnect, reconnect, and perform another leak check. If you
continue to see bubbles after several attempts, the cylinder valve is defective and
should be returned to the cylinder’s place of purchase.
•Do not transport heater while it’s operating.
•Do not move the heater after it has been turned off until the temperature has
cooled down.
•Keep the ventilation opening of the cylinder enclosure free and clear of debris.
•Do not paint the radiant screen, control panel or top canopy reflector.
•Control compartment, burner and circulation air passageways of the heater must
be kept clean. Frequent cleaning may be required as necessary.
•The LP tank should be turned off when the heater is not in use.
•Check the heater immediately if any of the following occurs:
oThe heater does not reach temperature.
oThe burner makes popping noise during use (a slight noise is normal
when the burner is extinguished).
oSmell of gas in conjunction with extreme yellow tipping of the burner
flames.

5
•The LP regulator/hose assembly must be located out of pathways where people
may trip over it or in area where the hose will not be subject to accidental
damage.
•Any guard or other protective device removed for servicing the heater must be
replaced before operating the heater.
•Adults and children should stay away from high temperature surfaces to avoid
burns or clothing ignition.
•Children should be carefully supervised when they are in the area of the heater.
•Clothing or other flammable materials should not be hung on the heater or
placed on or near the heater.
•Change the gas cylinder in a amply ventilated area, away
from any ignition source (candle, cigarettes, other flame
producing appliances, ...).
•To check that the regulator seal is correctly fitted and able to
fulfill its function, check the appliance as shown in the
picture on the right.
•Do not obstruct the ventilation holes of the cylinder housing.
•Close the gas supply at the valve of the gas cylinder or the
regulator after use.
•In the event of gas leakage, the appliance shall not be used or if alight, the gas
supply shall be shut off and the appliance shall be investigated and rectified
before it is used again.
•Check the hose at least once per month, each time the cylinder is changed,or
each time before a long time of no use. If it shows signs of cracking, splitting or
other deterioration, it shall be exchanged for new hose of the same length and of
the equivalent quality.
•The use of this appliance in enclosed areas can be dangerous and is PROHIBITED.
•Read the instructions before using this appliance. The appliance must be
installed in accordance with the instructions and local regulations.
•For connection of hose and regulator,and connection of regulator and hose,
please refer to photo showed above.
•This product contains small batteries. Ingestion of small batteries may present a
CHOKING HAZARD. If batteries are swallowed or inhaled, seek medical attention
immediately. Keep children away from small batteries.
•Do not block the vents of the storage space for the gas cylinder.

6
HEATER STAND AND LOCATION
•The heater is intended for outdoor use only. Always ensure that
adequate fresh air ventilation is provided.
•Always maintain proper clearance to non protected combustible
materials i.e. top 100 cm and sides 100 cm minimum).
•Heater must be placed on level, firm ground.
•ever operate heater in an explosive atmosphere, such as in areas
where gasoline or other flammable liquids or vapors are stored.
•To protect heater from strong wind, anchor the base securely to
the ground with screws.
GAS REQUIREMENTS
•Use propane, butane or their mixture gas only.
•The pressure regulator and hose assembly to be used must
conform to local standard codes.
•The installation must conform to local codes, or in the absence of local codes, with
the standard for the storage and handling of liquid petroleum gases.
•A dented, rusted or damaged tank may be hazardous and should be checked by your
tank supplier. Never use a tank with a damaged valve connection.
•The tank must be arranged to provide for vapor withdrawal from the operating
cylinder.
•Never connect an unregulated tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A
complete gas tightness check must be performed at the installation site due to possible
mishandling in shipment or excessive pressure being applied to the heater.
•Make a soap solution of one part liquid detergent and one part water. The soap
solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in
case of a leak.
•The heater must be checked with a full cylinder.
•Make sure the safety control valve is in the OFF position.
•Turn the gas supply ON.
•In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the
gas supply on and recheck.
•Never leak test while smoking.

7
OPERATION AND STORAGE
TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the variable control knob to PILOT position (counter-clockwise 90°).
3. Press down the variable control knob and hold for 90 seconds, While holding on the
variable control knob, press the igniter button several times until the pilot frame
lights. Release the variable control knob after the pilot flame lights..
NOTE:
•If a new tank has just been connected, please allow at least one minute for the air
in the gas pipeline to purge out through the pilot hole.
•When lighting the pilot frame, make sure that the variable control knob is
continuously pressed down while pressing the igniter button. The variable
control knob can be released after the pilot flame lights.
•Pilot flame can be watched and checked from the small round window with a
sliding lid located at the bottom of the flame screen (to the left or the right side of
the controller).
•If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights up, turn the variable control knob to maximum position
and leave it there for 5 minutes or more before turning the knob to the desired
temperature position.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT position.
2. Press and turn the variable control knob to OFF position.
3. Turn off the valve on the gas supply cylinder.

8
STORAGE
1. Always close the gas valve of the gas cylinder after use or in case of a disturbance.
2. Remove the pressure regulator and the hose.
3. Check the tightness of the gas valve, and check for damage. If you suspect damage,
have the parts changed or repaired by your gas dealer.
4. Never store liquid gas cylinders in a sub-terrain, or at places without adequate air
ventilation.

9
CLEANING AND CARE
•Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with
cleaners that are combustible or corrosive.
•Remove debris from the burner to keep it clean and safe for use.
•Cover the burner unit with the optional protective cover when the heater is not in
use.
PARTS AND SPECIFICATIONS
A. Construction and characteristics
•Transportable terrace/garden heater with tank housing.
•Casing in steel with powder-coating or in stainless steel.
•Gas hose connections with metal clamp (screw caps for Germany).
•Heat emission from reflector.

10
B. SPECIFICATIONS
•Use propane,butane or their mixtures gas only.
•Max. wattage: 13000 watts
•Min. wattage: 5000 watts
•Consumption:
APPLIANCE
CATEGORY:
I3B/P(30)
TYPES OF GAS:
Butane, propane or their mixtures
GAS PRESSURE:
30 mbar
OUTLET
PRESSURE OF
REGULATOR:
30 mbar
•Using the proper regulator according to outlet pressure of regulator as showed in
the table above.

11
C. TABLE OF INJECTOR
APPLIANCE
CATEGORY:
I3B/P(30)
TYPES OF GAS:
Butane, propane or their mixtures
GAS PRESSURE:
30 mbar
TOTAL HEAT
INPUT
(Hs) : (Qn)
13kW (G30:945g/h; G31:929g/h)
INJECTOR SIZE:
1,90 mm for main burner
0,18 mm for pilot burner
The marking, for example, 1.90 on the injector,
indicates that the size of injector is 1.90mm
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding appliance category in B.
Specification.
The appliance requires approved hose in 1.4m length.
Destination
Countries:CZ/SK/HU

12
ASSEMBLY PARTS
Tools needed:
•Philips screwdriver w/ medium blade.
•Open end wrench 10 & 13 mm
•Adjustable opening wrench (2) 20 cm long
•Slip joint pliers 23 cm long
•Spray bottle of soap solution for leakage test.
Parts List:
PART
DESCRIPTION
QUANTITY
A
Reflector Panel
3
B
Reflector Plate
1
FF
Reflector Stud
3
C
Head Assembly
1
D
Cylinder Housing
1
E
Post
1
F
Gas Hose
1
G
Support Bracket
3
H
Base
1
I
Wheel Kit
1

13
AA
M8 Flange nut × 2
BB
Bolt M8 X 16 × 2
CC
M6 Flange nut × 6
DD
Stainless steel bolt × 1
EE
Bolt M6 x 30 × 6
FF
Reflector spacer × 3
GG
Washer Φ8 × 9
HH
Washer Φ6 × 9
II
Screw M6 X 10 × 9
JJ
Cap nut × 9
KK
Wing nut × 3
LL
Wrench × 1

14
ASSEMBLY PROCEDURES
STEP 1
1-1. Put the 3 pcs post brackets on each position on
the base as shown in the picture.
1-2. Use 3 Medium Bolts(M8x16) to join the post
brackets and stand.
STEP 2
2-1. Put the post on the top of 3 pcs post brackets.
2-2. Use 6 Large Bolts and Flange Nuts (M6) to
connect the post to the 3 pcs post brackets. Tighten
the bolts and nuts.

15
STEP 3
Place the tank housing on the stand.
STEP 4
4-1. Remove the 4 bolts from the burner.
4-2. Put the gas hose through into the post.
4-3. Fix the burner unit to the post by the 4 bolts

16
STEP 5
5-1. Check whether the connection of vertical post and
burner are assembled according to instructions, and all
bolts and nuts are tightened.
5-2. Put 6 pcs Large Flat Washers on 3 Reflector Spacers.
STEP 6
Fasten the reflector with 3 pcs Large Flat Washers and 3
pcs Wing Nuts.
STEP 7
7-1. Bring up the tank housing and rest it on the post
plate.
7-2. Connect the end thread of inlet gas hose to the
regulator.
7-3. Connect the regulator to the gas tank and tighten it
with adjustable wrench.
7-4. Put LPG gas tank on the stand.
7-5. Fasten cylinder with propane tank strap.

Assembly OF K/D Wheels
17

To protect heater from strong wind, anchor the base securely to the ground with screws.
1. Reverse the base, fix the ground fixer to the base with bolts and washers like picture shows.
2. Secure the ground fixer with nuts.
3. Fix another two ground fixer with bolts and nuts, and reverse the base.
x 6 x 6 x 6
AA BB CC DD
Bolt M6 x 10
x 3
BB
AA DD
CC
Ground Fixer washer Φ6 Nut M6
18

4 SLICES ALU.REFLECTOR INSTALLATION
Warning: remove protective cover before assemble.
19

20
PROBLEM CHECK LIST
PROBLEM
PROBABLE CAUSE
SOLUTION
Pilot will not light
•Gas valve may be OFF
•Tank fuel empty
•Opening blocked
•Air in supply system
•Loose connections
•Turn the gas valve ON
•Refill LPG tank
•Clean or replace
opening
•Purge air from lines
•Check all fittings
Pilot will not stay
on
•Debris around pilot
•Loose connections
•Thermocouple bad
•Gas leak in line
•Lack of fuel pressure
•Clean dirty area
•Tighten connection
•Replace thermocouple
•Check connections
•Tank near empty. Refill
LPG tank.
Burner will not light
•Pressure is low
•Opening blocked
•Control not ON
•Thermocouple bad
•Pilot light assembly bent
•Not in correct location
•Tank near empty. Refill
LPG tank.
•Remove and clean
•Turn valve to ON
•Replace thermocouple
•Place pilot properly
•Position properly and
retry
If the appliance is in case of any defaults or problems of assembly or use, please don’t