INSTRUCTION SHEET
Installation and Operation of BIB Air Vent Assembly
DATE: 12/22/98
PN: 28-0011/02
1. MOUNTING INSTRUCTIONS
1.1 WALL MOUNT
The "Bib Air Vent" assembly can be mounted directly to a wall with four (4) #8 self tapping wood screws, 3/4" long. Mount
valve assembly with vent hole up, level and square to walI.
1.2 LANCER PUMP MOUNT
The "Bib Air Vent" assembly can be mounted directly to a Lancer Syrup Pump (PN 82-0109, with sold-out) by the following
method:
A. Remove the screw indicated in Figure 1 from the left hand end cap of the Lancer pump body. Discard screw.
B. Assemble connector (PN 54-0037) to "Bib Air Vent" inlet port. Secure with one (1) short screw (PN 04-0317).
C. Insert connector into Lancer pump syrup outlet port. Snap fingers over sold-out device. Secure with one (1) short screw
(PN 04-0317).
D. Align wall mounting leg with screw hole on end cap of pump body. Secure with one (1) long screw (PN 04-0313).
2. HOSE CONNECTIONS
Connect pump "syrup outlet" hose into "Bib Air Vent" inlet port with 3/8" barb fitting. Connect outlet hose with 3/8" barb fitting from
outlet port on "Bib Air Vent" to inlet port on dispenser.
3. OPERATION
When properly connected to the discharge side of a syrup pump, the "Bib Vent" will safely remove air which has been introduced
into the system through vacuum leaks or connecting fresh Bib packages. The unwanted air accumulates in the upper chamber of
the vent's primary reservoir and compresses due to inlet syrup pressure. As additional air is introduced, it displaces the syrup. When
the syrup level decreases, the primary float drops away from the seat, allowing an instant release of air to transfer through the
secondary reservoir and to the atmosphere.
This cycle is repeated as additional air is introduced to the Bib system. The vent's secondary reservoir acts as a safety chamber,
should the primary reservoir float fail. If syrup transfers to the secondary reservoir, instead of the air then the secondary float will
rise in the transferred syrup and seal against the air's outlet seat, thereby and preventing syrup from escaping.
4. CLEANING AND SANITIZING
Cleaning and sanitized should be performed concurrent with sanitization of the Bib system.
WARNING
ALL INTERNAL PRESSURE MUST BE PURGED BEFORE REMOVING PLUGS OR DISASSEMBLY.
If a more stringent cleaning is required, then the transfer tube and secondary reservoir can be sanitized by removing the clean out
plugs.
Figure 1
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
• USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242 •
• EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •
FAX ENGINEERING: • 210-310-7096
"Lancer" is the registered trademark of Lancer • Copyright — 1998 by Lancer, all rights reserved.
1
ITEM PART NO. DESCRIPTION
1 05-0334/01 Bowl, Reservoir, BIB Vent
2 02-0135 O-Ring, Cap (2-138)
3 54-0036 Float Assy, Primary
4 10-0133 Pin, Hinge, BIB Vent
5 05-0338 Seal, Primary, Float, BIB Vent
6 05-0335 Cap, Reservoir, BIB Vent
7 04-0313 Screw, 8 - 32 x 0.625, THMS, PH,
SS
8 04-0155 Screw, 8 - 16 x 0.437, PHD, PH,
PLT, SS
9 03-0005 Retainer, Single, SM
10 01-1059 Plug, Valve, Sold Out, Assy
11 05-0340 Seal, Secondary, BIB Vent
12 02-0134 O-Ring (2-116)
13 14-0006 Ball, Hollow, 3/8 Inch, BIB Vent
14 54-0037 Connector Assy
15 04-0155 Screw, 8 - 16 x 0.437, PHD, PH, PLT,
SS
16 03-0005 Retainer, Single, SM
17 04-0155 Screw, 8 - 16 x 0.437, PHD, PH, PLT,
SS
18 01-1059 Plug, Valve, Sold Out, Assy
19 04-0155 Screw, 8 - 16 x 0.437, PHD, PH, PLT,
SS
20 03-0056 Retainer, Fitting, Syrup, SS
21 04-0189 Insert, 8 - 32 x 0.300
ITEM PART NO. DESCRIPTION
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
82-2684

Other lancer Control Unit manuals

lancer STANDARD LEVER User manual

lancer

lancer STANDARD LEVER User manual

lancer 82-2509 User manual

lancer

lancer 82-2509 User manual

lancer 21000165 Manual

lancer

lancer 21000165 Manual

lancer 82-3049 User manual

lancer

lancer 82-3049 User manual

Popular Control Unit manuals by other brands

Hilintec C15 user guide

Hilintec

Hilintec C15 user guide

Flowserve FlowTop V726 DISASSEMBLY AND REASSEMBLY INSTRUCTIONS

Flowserve

Flowserve FlowTop V726 DISASSEMBLY AND REASSEMBLY INSTRUCTIONS

CKD MN4KB1 Series instruction manual

CKD

CKD MN4KB1 Series instruction manual

Asco 8317 Series Installation & maintenance instructions

Asco

Asco 8317 Series Installation & maintenance instructions

Vixen Horns VXA7164 installation guide

Vixen Horns

Vixen Horns VXA7164 installation guide

Broadcom CVPM02 user guide

Broadcom

Broadcom CVPM02 user guide

GRAUPNER HoTT 2.4 manual

GRAUPNER

GRAUPNER HoTT 2.4 manual

Racelogic VB3iS Using

Racelogic

Racelogic VB3iS Using

Burkert 3320 operating instructions

Burkert

Burkert 3320 operating instructions

Safeway water BNT85 Series Operation manual

Safeway water

Safeway water BNT85 Series Operation manual

Acromag BusWorks 900EN Series user manual

Acromag

Acromag BusWorks 900EN Series user manual

Toshiba IK-TF5U instruction manual

Toshiba

Toshiba IK-TF5U instruction manual

Woodward TecJet 52 Gen II Installation and operation manual

Woodward

Woodward TecJet 52 Gen II Installation and operation manual

T&S B-0504 Installation and maintenance instructions

T&S

T&S B-0504 Installation and maintenance instructions

Astronics Vertical Power Installation and operating manual

Astronics

Astronics Vertical Power Installation and operating manual

DeZurik KGC manual

DeZurik

DeZurik KGC manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

AMX AXB-DTMF Plus Specifications

AMX

AMX AXB-DTMF Plus Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.