manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lantronix
  6. •
  7. Recording Equipment
  8. •
  9. Lantronix XPortPro Web-i User manual

Lantronix XPortPro Web-i User manual

Other Lantronix Recording Equipment manuals

Lantronix NM2-GXE-2230 201 Series User manual

Lantronix

Lantronix NM2-GXE-2230 201 Series User manual

Lantronix 222 Series User manual

Lantronix

Lantronix 222 Series User manual

Popular Recording Equipment manuals by other brands

ThermoFisher Scientific Dionex DRS 600 Installation checklist

ThermoFisher Scientific

ThermoFisher Scientific Dionex DRS 600 Installation checklist

Shure ANIUSB-Matrix user guide

Shure

Shure ANIUSB-Matrix user guide

Nady Audio HE-1 user guide

Nady Audio

Nady Audio HE-1 user guide

AUDAC APM 01 User manual & installation guide

AUDAC

AUDAC APM 01 User manual & installation guide

Teac GF-350 owner's manual

Teac

Teac GF-350 owner's manual

Fractal Audio MFC-101 MARK III owner's manual

Fractal Audio

Fractal Audio MFC-101 MARK III owner's manual

bmcm USB-OI16 manual

bmcm

bmcm USB-OI16 manual

HHB BurnIT CDR-830 Service manual

HHB

HHB BurnIT CDR-830 Service manual

GE VersaMax IC200CPUE05 manual

GE

GE VersaMax IC200CPUE05 manual

IntesisBox MH-RC-MBS-1 user manual

IntesisBox

IntesisBox MH-RC-MBS-1 user manual

Attero Tech unD4l user manual

Attero Tech

Attero Tech unD4l user manual

Sennheiser UI 765 instruction manual

Sennheiser

Sennheiser UI 765 instruction manual

Sony RCD-W1 Operating Instructions  (primary... Service manual

Sony

Sony RCD-W1 Operating Instructions (primary... Service manual

Roland Planet-P  MKS-10 owner's manual

Roland

Roland Planet-P MKS-10 owner's manual

Roland BOSS GT-PRO Turbostart

Roland

Roland BOSS GT-PRO Turbostart

8x8 Inc Valcom V-2001A manual

8x8 Inc

8x8 Inc Valcom V-2001A manual

Waves SUB Align user guide

Waves

Waves SUB Align user guide

Mitsubishi Electric MAC-334IF-E installation manual

Mitsubishi Electric

Mitsubishi Electric MAC-334IF-E installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

This manual will guide you through the setup and use of all Reactor Series relay controllers. Following this manual in the sequence outlined is absolutely essential to proper understanding and use of
Reactor Series Controllers. Please review the entire manual BEFORE contacting NCD technical support. NCD technical support staff will direct your questions to this manual when applicable.
Page 1 Quick Start Guide: Web-i
Internet (Web) Interface Module
Copyright © 2012
National Control Devices
All Rights Reserved.
NOTICE: Portions of this Manual REQUIRE Internet Access
Web-i
Quick Start Guide
This manual will guide you through the setup and use of all Reactor Series relay controllers. Following this manual in the sequence outlined is absolutely essential to proper understanding and use of
Reactor Series Controllers. Please review the entire manual BEFORE contacting NCD technical support. NCD technical support staff will direct your questions to this manual when applicable.
Page 2 Quick Start Guide: Web-i
Web-i Setup
Things you will need
• A computer running Window XP, Vista, or Windows 7
(only required for IP Address discovery)
• Web-i Device Discovery Utility:
(http://assets.controlanything.com/Software/NCD-
WebiDiscovery.zip)
• Once a device has been discovered, any web browser
from any device or computer is required to access the
Web-i interface.
• A device with a Web-i interface
• A Router (make sure you are using a Router, not a
Ethernet switch)
• You will have to configure port forwarding on your rout-
er to access the Web-i over the internet. If you are un-
familiar with this process, please visit
www.portforward.com for explicit instructions for your
router model.
Things you will need to know
• IPAddress for Web-i Device
• Port Number of Web-i Device
• Default Device Login: webi
• Default Device Password: 1234
*This can be configured in the “Device Configuration”
portion of the interface, scroll down to “Set Up the Pass-
word for the Device” section.
• Default FTP Login: webftp
• Default FTP Password: 1234
This manual will guide you through the setup and use of all Reactor Series relay controllers. Following this manual in the sequence outlined is absolutely essential to proper understanding and use of
Reactor Series Controllers. Please review the entire manual BEFORE contacting NCD technical support. NCD technical support staff will direct your questions to this manual when applicable.
Page 3 Quick Start Guide: Web-i
Getting Started
1. Make sure you have thoroughly read all precautions for
you device to avoid damaging your controller.
2. Connect your Web-i enabled device to your router using
an Ethernet cable. DO NOT Connect the Web-i to a
Ethernet Switch, you MUST connect it to a Router for
proper operation. Connect an appropriate power supply
for your device.
3. Download the Discovery Utility.
http://assets.controlanything.com/Software/NCD-
WebiDiscovery.zip
4. Unzip the contents of the Web-i discovery software into a
folder making sure all files are included in the same
folder. Run the discovery software.
*Windows may alert you the Web-i discovery soft
ware is attempting to access your network. Choose
the “Allow Access” option.
5. The Web-i discovery software will scan your network for
Web-i communication modules. Each device will be
listed by the Mac Address. There should be at least
one Web-i module listed. If there are several listings,
there are multiple Web-i or .net devices on the same
router. If this happens, simply match the Mac Address
printed on the top of your module, located underneath
the barcode, against the available listings and discover
your module that way.
6. Double click on the appropriate available Mac Address
for your Web-i device. This should open a new tab in
your favorite browser.
*If this program did not work for you:
• You need .net version 3 or higher. This should be avail-
able to you through Windows updates.
• If you cannot obtain this software through Windows
updates, you can download this free software from Mi-
crosoft using a Google search. Search “.net framework
v3 download.” It should be the first result from Mi-
crosoft.com and can be downloaded and installed
through their website.
7. At this point, you should see a Web-i web-page appear.
This web page is generated by the Web-i module and
will allow you to access and control your device over a
local area network or from anywhere in the world (with
some additional setup).
Remote Internet Access
Web-i controllers can be accessed remotely through an
internet connection using any device with an embedded
web browser such as a Smart Phone, Tablet, or Computer.
To do this simply open the web browser on your device,
enter link.signalswitch.com/Your Mac Address. The Mac
Address should be entered without the colons, dashes, or
spaces.
Example: link.signalswitch.com/00204ael35ff
Note: The device may only be accessed in this way when
the Web-i controller and web browser are connected using
different networks. If the controller and device are on the
same Local Area Network do not use link.signalswith.com,
simply enter the devices IP address into the URL.
Also note that port forwarding must be configured on your
router. To setup port forwarding, you will need:
The IP Address of the Web-i Device on your LAN
The Port Number of the Web-i Device (usually 8080)
Please Visit www.portforward.com for complete instructions
on how to setup port forwarding on your router, as most
brands and models are covered with explicit directions on
this web site.
Note:
The Web-i listens on port 2101 if you would like to access
this device through a TCP/IP Socket connection. The Web-i
provides web page content on port 80.
Web-i Setup