Designation 100Base-FX
Typical Distance 2 Km
Nominal Wavelength 1310 nm
Cable Type 62.5/125 mm
Connector SC
Optical Budget 15 dB
Serial Interface 5-port 10/100Base-TX or 4-port 10/100Base-TX 8-port 10/100Base-TX 8-port 10/100Base-TX, plus 1-port
plus 1-port 100Base-FX 100Base-FX (optional)
Forward and Filtering Rate 14,880 pps for 10 Mbps 148,810 pps for 100 Mbps 14,880 pps for 10 Mbps
148,810 pps for 100 Mbps 14,880 pps for 10 Mbps 148,810 pps for 100 Mbps
Address Table Size 2048 MAC addresses 2048 MAC addresses 4K MAC addresses
Latency Less than 5.1
µ
s Less than 7.1
µ
s Less than 9.6
µ
s
Reverse Polarity Protection n/a n/a Yes
Network Interface 10/100 Mbps full/half-duplex,auto negotiation, 10/100 Mbps full/half-duplex,auto negotiation, 10/100 Mbps full/half-duplex,auto negotiation,
auto MDI/MDIX auto MDI/MDIX auto MDI/MDIX
LED Indicators Per Unit:Power Status Per Unit:Power Status (Power 1,Power 2) Per Unit:Power Status (Power 1,Power 2)
Per Port:10/100TX, 100FX: Link/Activity (Green),Speed (Yellow)
Per Port:10/100TX, 100FX: Link/Activity (Green)
, Per Port:10/100TX,100FX:Link/Activity (Green),Speed (Yellow)
Speed (Yellow),Fault (Red)
Management n/a n/a RS-232 console,Telnet,SNMP V1 & V2, RMON,
Web browser,TFTP
Alarm Contact n/a One relay output with current 1A @ 24VDC One relay output with current 1A @ 24 VDC
Standards IEEE802.3 10Base-T,IEEE802.3u 100 Base-TX/100Base-FX,IEEE802.3x IEEE802.3 10Base-T,IEEE802.3u 100 Base-TX/100Base-FX,IEEE802.3x IEEE802.3 10Base-T, IEEE802.3u 100 Base-TX/100Base-FX
IEEE802.3x,IEEE802.1Q,IEEE802.1p,IEEE802.1w
Power Input Voltage:12 to 48 VDC Input Voltage:10 to 48 VDC Input Voltage:10 to 30 VDC
Input Current:0.1A max. Input Current:1.5A max. Input Current:2A max.
Power Consumption:2.4W max. Power Consumption:24 VDC @ 0.55A,18.48 W max. Power Consumption:24 VDC @ 0.77A,18.48 W max.
Environmental OperatingTemperature:-10° to 60° ° C (-14° to 140° F) Operating Temperature:-34° to 74° ° C (-29° to 165° F) Operating Temperature:-34° to 74° ° C (-29° to 165° F)
StorageTemperature:-25° to 85° C (-13° to 185° F) StorageTemperature:-40° to 85° C (-40° to 185° F) Storage Temperature: -40° to 85° C (-40° to 185° F)
Humidity: 10% to 90% relative humidity (non-condensing) Humidity: 10% to 95% relative humidity (non-condensing) Humidity: 10% to 95% relative humidity (non-condensing)
Protocols Supported n/a n/a IGMP, GVRP,SNMP V1/V2,RMON,TFTP
Packet Buffer Memory 384 kilobit 768 kilobit 256 KB
Packaging Plastic case with DIN-rail mounting Aluminum case with DIN-rail,or panel mounting Aluminum case with DIN-rail,panel or rack mounting
Dimensions: 25 mm W x 70 mm D x 110 mm H 50 mm W x 110 mm D x 136 mm H 50 mm W x 125 mm D x 135 mm H
(0.99" W x 2.76" D x 4.33" H) (1.97" W x 4.33" D x 5.35" H) (1.97" W x 4.92" D x 5.31" H)
Weight: 0.2 Kg (0.44 lbs.) 0.8 Kg (1.76 lb) 0.8 Kg (1.76 lb)
Processing Types Store-and-forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Standards IEEE802.3 10Base-T, IEEE802.3u 100 Base-TX/100Base-FX, IEEE802.3x
Regulatory Approvals:
Emission Compliance FCC Part 15, Class A
ISO Manufactured in an ISO9001 facility
Safety UL 60950 UL 60950,EN 60950, IEC 60950, IEC 61000-6-2,UL 1604:Classified for ITE Equipment for use in hazardous locations:
Class 1,Division 2 group A, B,C & D:Temp Code T4A;-25C° < Tamb < 74C°
CE Approval n/a EN55022 (CISPR22 Class A),EN55024 (CISPR24 Class A)
ESD Standards (IEC 61000-4-2) n/a Enclosure Contact: + / - 4 KV;Criteria B,Enclosure Air:+ / - 8 KV; Criteria B
Radiated FRI Standards (IEC 61000-4-3)
n/a Enclosure Ports:10 V/m,80 to 1000 MHz; Criteria A
Burst Standards (IEC 61000-4-4) n/a Enclosure Ports: + / - 4 KV @ 2.5 KHz; Criteria B,DC Power Ports: + / - 4 KV;Criteria B,AC Power Ports:+ / - 4 KV;Criteria B
Surge Standards (IEC 61000-4-5) n/a Signal Ports:+ / - 1 KV;Line-to-earth; Criteria B,DC Power Ports: + / - 0.5 KV;Line-to-earth; Criteria B
AC Power Ports:+ / - 2 KV;Line-to-earth; Criteria B
Induced RFI Standards (IEC 61000-4-6)
n/a Signal Ports:10V @ 0.15 - 80 MHz; Criteria A, DC Power Ports:10V @ 0.15 - 80 MHz; Criteria A
AC Power Ports:10V @ 0.15 - 80 MHz; Criteria A,Earth Ground Ports:10V @ 0.15 - 80 MHz; Criteria A
Magnetic Field Standards (IEC 61000-4-8)
n/a Enclosure Ports: 30 A/m @ 50, 60 Hz;Criteria A
Voltage Dip Standards (IEC 61000-4-11)
n/a AC Power Ports:30% Reduction for 0.5 period; Criteria B
Environmental Test Compliance n/a (IEC 60068-2-6) Vibration Resistance:5G @ 150 Hz; Criterion 3 (Operation/Storage/Transport)
(IEC 60068-2-27) Shock:
• 5 G @ 11 ms (Half-Sine Shock Pulse;Operation)
• 50 G @ 11 ms (Half-Sine Shock Pulse;Storage/Transport)
(IEC 60068-2-32) Free Fall:1 M (3.281 ft.)
NEMA TS1/2 Environ. Requirements n/a Yes
for Traffic Control Equipment
Installation Type: DIN Rail (mounting kit is included) DIN Rail (mounting kit is included) DIN Rail (mounting kit is included)
Optional wall-mount kit,ordered separately (X9294PMKT-01) Optional wall-mount or rack-mount kit,ordered separately
(X9294DRKT-01),(X9294PMKT-01)
XPress-Pro SW Model: 52000 92000 94000