Explosion Proof Motion Sensor - 10' to 20'
Mounting Height - 15' x 15' Area -
Adjustable Timer - 12V - KNX
InstructionManual
Thank youfor your purchase of the EXP-AKC-MS-N4X-AT-LV-12V MotionSensor, the following instructions are
intendedfor this part number only.
Installation
This unit is easily wall mountedvia integral mounting bracket, which can be adjusted-90° to +30° vertically after
installation. The explosion proof housing provides two 1/2" or 3/4" hub openings locatedon either side of thehousing for
running electrical conductors in a feed through configuration. A bushing seal at each conductor opening prevents
damage to wiring insulation.
KNX Connections: This motion sensor operates on 12V DC and features two monitored inputs, as well as two
monostable relay outputs. The explosion proof interface is suitable for sending output signals from the motion sensor to
upstream systems. This unit contains bus terminals (black/red) for connection with KNX components. Screw terminals
are provided for connecting auxiliary voltage, inputs and outputs. This motionsensor is suitable for use in environments
where combustible dusts and particulates may be present. 1/2" or 3/4" NPT tapped conduit openings are provided on
either of the unit in feed through versions while dead end versions have a single conduit hub, providingeasy and secure
connectionto main power linesupplies.
The EXP-AKC-MS-N4X-AT-LV-12V operates like a standard on/offlight switch. Thecircuit is normally open when no
motion is present. Once motionis detected, theinternal switch changes to a closed circuit, allowingvoltageto pass
through the sensor and power the device(s) at theother end.
Thesensor is an active motiondetector; it emits high-frequency electro-magnetic waves (5.8GHz) and receives their
echo. Thesensor detects thechange in echo from eventhe slightest movement in its detectionzone. A microprocessor
then triggers the“switch light ON” command. Detection is possible through doors, panes of glassor thin walls.
IMPORTANT: persons or objects movingtowards the sensor are detected best.
NOTE: the highfrequency of the output ofthis sensor is <10Mw – that is just one 100th of the transmission
power of a mobile phone or the output ofa microwave oven.
Larson Electronics, LLCPhone: (800) 369-6671 Fax: (903) 498-3364www.larsonelectronics.com
2of 3
MOTION SENSOR
Operating voltage
Rated load
HF system 5.8GHz±75MHz, ISM wave band
Transmitting power <0.5mW
Power consumption ≤0.5W(standby)
Detection zone Max.(D x H): 16m x 15m
Detection sensitivity 25% / 50% / 75% / 100%
Hold time 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor 5Lux/15Lux/30Lux/50Lux/100Lux/Disable
Mounting height 15m Max.
Motion detection 0.5~3m/s
Detection angle 150°(wall installation)
360°(ceiling installation)
Operating temperature -20℃~60℃
IP rating IP20
Setting
ON ON
ON
ON
ON ON ON
ON ON
ON ON
ON
ON ON
ON ON ON
ON
ON
ON
ON
I
II
III
IV
1 2
100%
75%
50%
25%
I
II
III
IV
V
3 4 5
IV
5s
30s
90s
3min
20min
30min
I
II
6 7 8
Disable
50lux
15lux
5lux
30lux
III
IV
V
Detection area can be reduced by selecting the combination on the
DIP switches to fit precisely each application.
Refers to the time period the lamp remains at 100% illumination after
no motion detected.
The sensor can be set to only allow the lamp to illuminate below a
defined ambient brightness threshold.
When set to Disable mode, the daylight sensor will switch on the lamp
when motion is detected regardless of ambient light level.
30lux, 50lux,100lux,:twilight operation, 5lux, 15lux: darkness operation only.
By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application.
100lux
ON
ON ON
ON
ON ON
When set to Disable, the microwave sensor function is inactive, lights turns on or off
by switch.
When set to Sensor, the microwave sensor function is active.
ON
Detection area
Hold time
Daylight sensor
Mode
EXP-AKC-MS-N4X-AT-LV-12V
Larson Electronics, LLCPhone: (800) 369-6671 Fax: (903) 498-3364www.larsonelectronics.com
3of 3
Certifications - Compliance
- Class I, Divisions 1 & 2, Groups B, C, D
- Class I, Zones 1 & 2, Groups IIB+H2, IIA
- Class II, Divisions 1&2, Groups E,F,G
- Class III, Divisions 1&2
- Ex db IIC Gb
- Ex tb IIC Gb Db IP66
- NEMA 3,4,4X,7 (B,C,D), 9 (E,F,G)
Malfunction
Cause
Remedy
The load will not work - wrong light control setting selected
- load faulty
- mains switch OFF
- adjust setting
- change load
- switch ON
The load is always working - continuous movement in the
detection zone
- check zone setting
Load works without and identifiable
movement
- sensor is not mounted for detecting
movement reliably
- movement occurred, but not
identified by the sensor (movement
behind a wall, movement of small
object in immediate vicinity etc.)
- securely mount enclosure
- check zone setting
The load will not work despite
movement
-rapid movements are being
suppressed to minimize
malfunctioning or the detection zone
you have set is too small
-check zone setting
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER
INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT
1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR WARRANTY AND RETURNINFORMATION.
EXP-AKC-MS-N4X-AT-LV-12V

Other Larson Electronics Accessories manuals

Larson Electronics EPLTS-T8 User manual

Larson Electronics

Larson Electronics EPLTS-T8 User manual

Larson Electronics EXP-MS-N4X-AT-LV User manual

Larson Electronics

Larson Electronics EXP-MS-N4X-AT-LV User manual

Larson Electronics EXP-MS-N4X-AT-HV User manual

Larson Electronics

Larson Electronics EXP-MS-N4X-AT-HV User manual

Larson Electronics EXP-MS-N4X-AT-HV-V6 User manual

Larson Electronics

Larson Electronics EXP-MS-N4X-AT-HV-V6 User manual

Larson Electronics SLEDB-110V-30C-XMS User manual

Larson Electronics

Larson Electronics SLEDB-110V-30C-XMS User manual

Larson Electronics EXP-MS-N4X-AT-HV-V5 User manual

Larson Electronics

Larson Electronics EXP-MS-N4X-AT-HV-V5 User manual

Larson Electronics EXP-MS-30W-N4X User manual

Larson Electronics

Larson Electronics EXP-MS-30W-N4X User manual

Larson Electronics EXP-MS-30W-N4X-SFC User manual

Larson Electronics

Larson Electronics EXP-MS-30W-N4X-SFC User manual

Larson Electronics IND-HL-HDB-FUVC-EX-1L-120V-15C User manual

Larson Electronics

Larson Electronics IND-HL-HDB-FUVC-EX-1L-120V-15C User manual

Larson Electronics MDSEN-IR-277V-R2 User manual

Larson Electronics

Larson Electronics MDSEN-IR-277V-R2 User manual

Larson Electronics EXP-DNMS-N4X-AT-HV User manual

Larson Electronics

Larson Electronics EXP-DNMS-N4X-AT-HV User manual

Larson Electronics XLE-PA-IP20-CS.50-50A-3PH-250V-3P4W-B User manual

Larson Electronics

Larson Electronics XLE-PA-IP20-CS.50-50A-3PH-250V-3P4W-B User manual

Larson Electronics SLEDB-277V-30C-XMS User manual

Larson Electronics

Larson Electronics SLEDB-277V-30C-XMS User manual

Larson Electronics IND-TBL-BX-R13-UVC-120V User manual

Larson Electronics

Larson Electronics IND-TBL-BX-R13-UVC-120V User manual

Larson Electronics ATEX-EXP-DNS-400W-M20-HV User manual

Larson Electronics

Larson Electronics ATEX-EXP-DNS-400W-M20-HV User manual

Popular Accessories manuals by other brands

Nice elero Aero-868 AC operating instructions

Nice

Nice elero Aero-868 AC operating instructions

Anton Paar ADU 5 Product information

Anton Paar

Anton Paar ADU 5 Product information

DAMM BS422 Installation and setup

DAMM

DAMM BS422 Installation and setup

MAGINON MPP 3000 K user manual

MAGINON

MAGINON MPP 3000 K user manual

POLTI SANI SYSTEM CHECK instructions

POLTI

POLTI SANI SYSTEM CHECK instructions

Buckeye SANI-Q operating instructions

Buckeye

Buckeye SANI-Q operating instructions

Pilz PSEN sl-1.0p 2.1 operating manual

Pilz

Pilz PSEN sl-1.0p 2.1 operating manual

SIKA VVX operating manual

SIKA

SIKA VVX operating manual

Menuett 013266 operating instructions

Menuett

Menuett 013266 operating instructions

Razor Ripstick Electric Guide

Razor

Razor Ripstick Electric Guide

Siemens RUGGEDCOM WIN7225 installation guide

Siemens

Siemens RUGGEDCOM WIN7225 installation guide

Kistler 6184AC Series Quick Start Installation

Kistler

Kistler 6184AC Series Quick Start Installation

Baumer OBDM 12N6910/S35A manual

Baumer

Baumer OBDM 12N6910/S35A manual

PCB Piezotronics 333B40 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 333B40 Installation and operating manual

HEIDENHAIN LIC 4007 Mounting instructions

HEIDENHAIN

HEIDENHAIN LIC 4007 Mounting instructions

AREBOS AR-HE-HD Series Original user manual

AREBOS

AREBOS AR-HE-HD Series Original user manual

Festo SDE1 Series operating instructions

Festo

Festo SDE1 Series operating instructions

ThermalStrike Heated Luggage user manual

ThermalStrike

ThermalStrike Heated Luggage user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.