manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LEDLITE
  6. •
  7. Work Light
  8. •
  9. LEDLITE RTWPLED5MW User manual

LEDLITE RTWPLED5MW User manual

Other LEDLITE Work Light manuals

LEDLITE LTTP5WIFI User manual

LEDLITE

LEDLITE LTTP5WIFI User manual

LEDLITE LTMFHT User manual

LEDLITE

LEDLITE LTMFHT User manual

LEDLITE LTCAWIFI User manual

LEDLITE

LEDLITE LTCAWIFI User manual

LEDLITE RTWPLED25MW User manual

LEDLITE

LEDLITE RTWPLED25MW User manual

Popular Work Light manuals by other brands

Conrad 77 70 78 operating instructions

Conrad

Conrad 77 70 78 operating instructions

EBS Seeberg 1 Operation manual

EBS

EBS Seeberg 1 Operation manual

Pelican 9460 user manual

Pelican

Pelican 9460 user manual

Anslut 425-080 User instructions

Anslut

Anslut 425-080 User instructions

Govee H6071 user manual

Govee

Govee H6071 user manual

LumX INSPEC LED instruction manual

LumX

LumX INSPEC LED instruction manual

LED2WORK TECLED User instructions

LED2WORK

LED2WORK TECLED User instructions

ANSMANN POWERLIGHT 5.1 operating instructions

ANSMANN

ANSMANN POWERLIGHT 5.1 operating instructions

RTRMAX RTX1868 instruction manual

RTRMAX

RTRMAX RTX1868 instruction manual

FeinTech LAL00220 quick start guide

FeinTech

FeinTech LAL00220 quick start guide

Bunker Hill Security 64735 user manual

Bunker Hill Security

Bunker Hill Security 64735 user manual

Goobay 30450 user manual

Goobay

Goobay 30450 user manual

REV Ritter SPOT Assembly and operating instructions

REV Ritter

REV Ritter SPOT Assembly and operating instructions

Ignition Stagepix Line 100 IP user manual

Ignition

Ignition Stagepix Line 100 IP user manual

SCANGRIP DUO CONNECT manual

SCANGRIP

SCANGRIP DUO CONNECT manual

Bosch GLI 18 V operating instructions

Bosch

Bosch GLI 18 V operating instructions

Bayco SL-1514 instruction manual

Bayco

Bayco SL-1514 instruction manual

EUFAB SMD LED 8+1 operating instructions

EUFAB

EUFAB SMD LED 8+1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

User Instructions
Please read these instructions and retain them for future reference.
IP65 220-240V
19-09-2016
Important information
It is recommended that the fittings are installed by a qualified electrician ensuring the installation
complies to current IEE wiring regulations & local building control.
• These products are designed for connection to a 220-240V mains supply.
• We cannot accept responsibility for any claims arising from a poor installation.
Important User Advice
• Always switch off mains supply before installation.
• The fitting is suitable for indoor and outdoor use.
• The installation must not infringe on water pipes or any other electrical services.
• The light fitting is Class II and it does not require an earth connection.
RTWPLED5MW
Dimensions:
Specifications:
1274mm
1339mm
1480mm
70mm
80mm
80mm
5ft 50W LED Non Corrosive
Weatherproof Fitting - IP65
with Microwave Sensor
230V
50/60Hz
IP65
NON DIMMABLE
• Voltage Range: 220-240V
• Nom. Watts: 50W
• Lumen Output: 4500lm
• Colour Temp.: 5000K
• IP Rating: IP65
• Warranty: 3 Years
• ABS Base
• Stainless Steel Clips
• Not Dimmable
Package Includes:
• Snap-in Metal clips x 2pcs.
• Plastic Wall Plugs x 4pcs.
• Screws x 4pcs.
• RC-102-B Remote Control
Sensor Specifications:
35.8mm
23mm
41mm
90mm
98mm
2.4 - 6m
Height of installation: 2.4 - 6m Detection Range 15m
(installation height 2.4-6m) Detection Angle
Max 6m
0
Max 15m / 360
10m
Sensor Coverage:
Remote Control Specifications: Remote Control Dimensions(mm):
● Control Range: up to 10m
● Battery Type: CR2025
Sensor
LED - 500W
This is a sealed fitting and must not be opened!
Opening this fitting will void the warranty!
Switch off the power source before installation & maintenance
Warning!
Installation:
Step 1: Identify the location and direction of any hidden supply cables or service pipes before
drilling fixing holes.
Step 2: Mark and drill mounting holes for the snap-in ceiling clips at the correct spacing (Fig.1).
Step 3: Fix the clips securely to the ceiling (A).
Installation*
33mm
61mm
(Fig.1)
24mm
*Can also be suspended with traditional hooks & Jack chain. Not supplied.
The fitting comes with both waterproof cable
glands installed, one side has a silicone cover
to ensure the IP65 rating. In order to utilize
both connections, remove the blanking plate
by unscrewing the cover.
1(Input)
2(Output)
Connection Block 2 (Output)
N
L
NEXT LIGHTLIGHT FITTING
(N)
(L)
Neutral
(Blue)
Live
(Brown)
(Fig.4)
Remote Control Setup:
● Pull plastic protection from battery compartment to activate the remote control.
● The factory settings by default are:
○ Range (sensitivity) 10 metres distance.
○ Time ( the time the fitting will stay on for) is 10 seconds.
○ (The light sensitivity) By default the sensor will function all day and night (2000Lux).
● Changing the default settings:
○ Point the remote towards the fitting within 10m metres and press the AUTO button.
○ Select the mode of adjustment required, eg, sensitivity (range). Press the required range be
it 2m, 4m, 10m etc.
○ The light will then flash once acknowledging the new setting.
○ Repeat the same for all other adjustments required (stand-by time, lux).
Remote Control Functions:
Range Adjustment
MAX detection distance 14-15m
10m detection distance
8m detection distance
6m detection distance
4m detection distance
2m detection distance
Light ON/OFF
ON - Manual ON switch
OFF - Manual OFF switch
overriding the sensor.
(sensor disabled in this mode)
After 6 hours the sensor goes
back into "AUTO" mode.
AUTO Mode
The sensor starts to work
automatically and all settings
remain the same as the latest
status before pushing ON/OFF
button, Test or Reset button.
Resets all functions
Default settings:
• 10m range
• 10 sec.
• 2000lux - Daylight mode
Test Mode
Hold the button for 2 seconds to
enter test mode. Time and lux
level are disabled in Test Mode.
Press Auto button to exit Test
Mode.
Time Adjustment
Min: 10 Sec.
Max: 60 Min.
Lux Level Adjustment
Set daylights threshold from
10lux to 2000lux.
For daylight mode use 500lux
to 2000lux settings.
Lux Level Overwrite
Sets the surrounding lux value as
the daylight threshold (overwrites
the existing lux values).
Allows the fitting to function in any
desired light circumstances.
Permanent Lock Mode
Permanent inhibition of the
sensor - light permanent ON/OFF.
Only the ON and OFF functions
on the remote are available.
Press button again to exit mode.
● ON/OFF Mode
○ When ON/OFF buttons are pressed the light is turned ON/OFF overriding the
sensor. The Batten fitting will enter AUTO mode after 6 hours.
○ To exit ON/OFF Mode press AUTO button.
● LOCK/UNLOCK Mode
○ When is pressed the remote control is locked, only ON and OFF functions on the remote are
available.
○ Push the button again to unlock the remote control.
Operation Modes:
(Fig.2)
Wiring Instructions:
(N)
POWER SUPPLY LIGHT FITTING
Neutral
(Blue)
Live
(Black)
Connection Block 1(Input)
Standard Wiring
Output
(Brown)
(L)
Connection Block 1(Input)
Master to Slave Wiring
(N)
POWER SUPPLY LIGHT FITTING
Neutral
(Blue)
Live
(Black)
Output
(Brown)
(L)
(Fig.3)
(Orange)
(Orange)
Master(M)
(OUT)
Step 4: Using a screw loosen and open the cover for the connection Block 1 and wire the main
input to the terminal block of the light fitting (B). The fitting comes pre-wired as a standard single
fitting (Fig.2) with a link between Live(L) and Output (OUT) connections and it can be wired as
a Master to Slave sensor fitting by connecting the Orange wire from Master (M) to the
Output (OUT) connection (Fig.3). Connection Block 2 is used for output only (Fig. 4).
For detailed wiring see the instructions below.
Step 5: Close the connection box cover (C) on the connection Block 1 and mount the light fitting
onto the metal clips ensuring that it is secured into place (D).
Step 6: Power up the fitting to check that it functions correctly (E).
(OUT)