LeMaitre Neutron XS Hazer User manual

www.lemaitrefx.com
Neutron XS
Operations Manual
v.01.03.01

www.lemaitrefx.com
Please Read Carefully Before Operating
Page 1 Introduction
Page 2 Warning
Page 3 Technical Specifications
Page 4 Operating Procedure
Page 5 Remote and E ternal Control
Features
Page 7 Maintenance
Page 10 Recommended Fluids
Page 10 Warranty
Page 11 Safety Precautions
Page 12 Accessories
Page 13 Notes
Table of Contents

www.lemaitrefx.com
Capture beams of light with a
translucent haze. The Neutron
XS Hazer, rewrites the book on
haze technology. Le Maitre’s
patented Sequentially Tracked
Auto Reissue technology
generates an environment of
translucent haze without the use
of a compressor or heating
block, providing a virtually
silent operation with instant
effect.
The haze is generated without
the use of oil, eliminating any
residue associated with cracked
oil effects.
Silent operation combined with continuous output, optional DMX and
remote control places the Neutron XS in a class of its own.
Features
Introduction
-Whisper Quiet Operation
-Continuous Haze Output
-1 allon of fluid lasts 160 Hours
-Micro-Processor Controlled
-DMX Interface (Optional)
-Integrated Fan
-Remote Control (Optional)
-Instant Effect
-Patented S.T.A.R. Technology
1

www.lemaitrefx.com
M.S.D.S. Available by request or at www.lemaitrefx.com
Warning
WARNING
READ T ESE IMPORTANT SAFETY INSTRUCTIONS
Do not remove the outer case until power has been
disconnected from the machine
READ T ESE IMPORTANT SAFETY INSTRUCTIONS
Persons suffering from asthma or allergenic
sensitivity may experience irritation, discomfort, or
allergic symptoms when exposed to heated
fog effects
IMPORTANT SAFETY INSTRUCTIONS
Do not touch or place hands, expose skin,
within 10 cm. of discharge nozzle.
SAVE T ESE INSTRUCTIONS
READ T ESE IMPORTANT SAFETY INSTRUCTIONS
WARNING
Ensure that this unit is grounded at all times.
Failure to do so may result in serious injury.
WARNING
Never use alternative fluids. Toxicity free output
is your responsibility.
2

www.lemaitrefx.com
Technical Specifications
Model: Neutron XS Hazer with S.T.A.R. Technology
Type: Water Base Haze Generating System
Dimensions: Length: 67 cm. / 11.25
Width: 28.5 cm. / 9
Height: 33 cm. / 10.94
Weight with Fluid: 11 Kg. / 23.75 lbs.
Power Rating: 115VAC 60HZ 3.15A
220VAC 50HZ 1.45A
Neutron XS Illustration
3

www.lemaitrefx.com
The machine should be fitted with a 2 litre Le Maitre Neutron Hazer
fluid container.
The use of any other fluid will lead to damage of the Hazing Ele-
ment .
Remove the main cover by releasing the two thumb screws, situated
rear top and front lower and sliding the cover forward, up and out.
1.) Place the bottle securely into the machine and remove its sealing
cap. Insert the fluid feed pipe and secure the fluid cap, making
sure that the air vent in the cap is clear from obstruction.
2.) Plug the machine into a suitable main power supply. Set the
Mains switch to the On position, located on the rear panel.
The Mains switch will illuminate to indicate the presence of Mains
power.
A clean power supply is essential
to the operation of the Neutron. For
this reason we do not recommend
the supply of mains power from a
lighting dimmer.
3.) Set the Haze switch to the On
position, located on the rear
panel.
The Monitor led should now
begin to flash continuosly indi
cating that the initial auto
cleanse phase has commenced.
Please note , if the Neutron XS Hazer shut down cycle has not been
allowed then it is possible that small amounts of fluid will be ejected
during the auto cleanse phase.
Operating Procedure
4
Note

www.lemaitrefx.com
4.) It will now be necessary to Prime fluid into the system to e pel
any air that might be present. This is done automatically and
can take up to eight minutes if fluid feed pipe is empty.
Note: On the most recent version of the Neutron XS a prime function
is available to speed up the fluid priming. The prime function is
activated by:
a.) Start with the mains switch and haze switch in the off position.
b.) Machine must be completely switched off for 20 seconds to allow power
supply to run down.
c.) Switch mains on, within 5 seconds of doing this switch haze switch on/off 5
times quickly leaving it in the on position.
This then gives you 20 pulses which is the quick prime.
To repeat this you start at step a.).
5.) Once the Neutron XS is primed, haze vapour will automatically
be issued in a cycling fashion. When the unit is operating normally
the LED will flash in pulses.
6. ) To stop haze issue, set the Haze switch to the Off position. The
Neutron XS will not immediately stop issuing haze, but will
enter into an additional auto cleanse phase. After this period the
Neutron XS will shut down, and the Monitor led will stop
flashing.
Remote and External Control Features
In addition to onboard controls, available for the Neutron XS, is a hand held
Standard Remote Control with On/Off capabilities.
The Neutron Remote (Part # CLF 2415) is avail-
able for applications where the Neutron XS will
be controlled from a remote location. To use the
Neutron Remote simply follow the directions
below:
1.) Select the Off position on the
Haze switch, located on the
rear panel of the Neutron XS.
2.) Ensure the power to the Neutron
is off, by selecting Off at the
Mains switch.
5
Neutron Remote

www.lemaitrefx.com
3.) Connect the remote cable connector to the 3 pin XLR located
on the rear panel of the Neutron XS.
4.) Power up the Neutron by selecting On at the Mains switch.
5.) The Power Indicator on the Neutron Re
mote should be illuminated at this time.
The Power Indicator remains illuminated
as long as the Neutron Remote is receiv-
ing power, it does not duplicate the
flashing of the Monitor Led.
6.) Start haze output by selecting On at
the Haze switch on the Neutron
Remote.
Pinout for 3 Pin XLR
Pin 1 - Remote Signal
Pin 2 - GND
Pin 3 - +12V
The D.M.X. Interface (Part # CLF
3320)will allow D.M.X. 512 Protocol
to activate the Haze output of the
Neutron XS Haze machine.
See the publication included with the
D.M.X. Interface for operating instruc-
tions.
Note
Service Note
D.M.X. Interface
6

www.lemaitrefx.com
Maintenance
Service Note
This following will outline the suggested schedule and procedure
for maintaining your Neutron XS processing tube, including a
proper Power Down procedure which must be followed to en-
sure the performance of your Neutron XS Hazer.
The following Power Down procedure MUST be followed each
time the power to the Neutron XS is turned off:
1.) Turn the Haze switch to the OFF
position to initiate the cleansing
cycle.
2.) The cleansing cycle will begin clearing
the processing coil of unprocessed
fluids. The monitor light will continue
to flash until the cleansing cycle has
ended, at which time the monitor
light will go out.
3.) The Mains power switch can now
be turned to the OFF position.
4.) The Power Down procedure is com-
plete.
Important Note
7

www.lemaitrefx.com
A routine maintenance program is essential for the optimum per-
formance of your Neutron XS Hazer. We recommend that the tube
maintenance program be applied at least every 25 hours of use, or
when a noticable decrease in output is observed. More frequent
maintenance will result in superior trouble free operation.
To make your maintenance regime more convenient and effective,
a Neutron Cleaning Kit is available from your Le Maitre dealer.
Included in this kit are e tra abrazors, cleaning solution, and a
spare Processing Tube. To order this kit use Part # CXP 2486.
Warning !
Make certain the power cord is unplugged
when servicing this unit. Failure to disconnect
may result in fatal electric shock, fire, or injury to
persons.
To avoid possible burns allow sufficient time for the
unit to cool.
1.) Disconnect power by unplugging unit from main power sup
ply.
2.) Remove top cover by loosening knob fasteners counter
clockwise.
3.) After removing top cover by sliding towards the
front and upwards, the lid will locate into notch
and lift away. Locate the Abrazor tool from behind
label, and remove.
Knob Fastener
Knob Fastener
8

www.lemaitrefx.com
4.) Remove service port cover to allow
easy access to the
processing coil.
5.) Support the processing tube with
one hand by simply grasping it
firmly near the end of the tube
where the haze e its. With abrazor
tool in hand, guide it through
the service port into the
processing coil with an in and out
motion. The burrs on the
Abrazor will de-scale
the walls , resulting
in a rejuvenated
processing tube.
For a better grip on the
Abrazor tool, a few turns of
electrical tape gives a better
grip of the cleaning tool.
6.) The unit is now ready to reassemble.
Take note of the alignment studs when
assembling the lid. Tighten
knob fasteners.
7.) The maintenance is complete.
Alignment
Studs
Alignment
Studs
Service Port
Tech tip
9

www.lemaitrefx.com
Recommended Fluids
Neutron Water Based Haze Fluid
The Le Maitre water based Neutron Haze Fluid provides a translu-
cent long lasting, dry haze effect that leaves no residue. For use
only in the Neutron product range only.
Warning!!
Never use Regular aze Fluid in your Neutron
Warranty Policy
Warranty:
The Neutron XS Hazer has a 1 Year Parts and Labour warranty
against manufactured defect only. If the Hazing Element Coil
becomes plugged it will NOT be considered warranty. Proof of
purchase or proof of sale must always accompany any warranty
returns. An RA (return authorization) number must be noted on
the outside of any bo returned to our facilities. Any packages
without a clearly marked RA number will not be accepted by
our receiving department. Proper maintenance and shut down
procedure must be followed to ensure Hazing performance.
Should your Hazing Element Tube become plugged a cleaning
procedure can be administered.
Freight on warranty items are freight prepaid to our facility and we
will prepay freight back to your facility after repair, by the most
economical means available. Should you require the item e press-
returned, then you are responsible for any difference in freight
cost.
10

www.lemaitrefx.com
Return Policy:
Return of any product must be done within 30 days of purchase.
The package must be returned freight prepaid and the RA number
clearly marked on the outside of the bo . A restocking charge of
up to 25% may be levied. Only credits are issued to the dealers
account. Any product not returned within 30 days is considered
purchased.
Warning:
Le Maitre Special Effects Inc. considers all it's product to be safe for
use in the application it was intended. Le Maitre Special Effects
takes no responsibility for misuse or incorrect use. Always refer to
equipment owners manual for proper use.
Safety Precautions
1. Ensure that operation of the machine is supervised by suitably
trained and authorised personnel.
2. Do not modify the machine or use a machine which has been
damaged in any way.
3. Allow sufficient air circulation around the machine at all times.
4. Protect the Neutron XS from direct weather effects.
5. Only use fluids recommended by the Manufacturer.
6. Do not continue to produce haze output in an enclosed area
when visibility is reduced below 50cm.
11

www.lemaitrefx.com
7. Avoid direct haze output continuously at persons, structure or
objects within close pro imity of the discharge nozzle.
8. Ensure that adequate e hausting arrangements are available in
the event of an emergency.
9. Do not place hands, or e posed skin within the first 10cm of the
discharge nozzle at any time during haze production.
Accessories
Listed below are accessories available for your Neutron XS through
your Le Maitre dealer.
12
Model Description
CLF 2415 Neutron Pro. Remote
CLF 3320 DMX Interface
CLF 2420 Neutron Road Case
CXP 2485 Replacement XS Hazer Coil
CLF 2421 Neutron Han
g
n
g
in
g
Bn
g
Bracket
CXP 2486 Neutron XS Coil Cleanin
g
g
Kit
( includes replacement tube)

www.lemaitrefx.com
Notes
13
Other LeMaitre Fog Machine manuals

LeMaitre
LeMaitre G300MkIII User manual

LeMaitre
LeMaitre Peasouper User manual

LeMaitre
LeMaitre G300-Smart User manual

LeMaitre
LeMaitre Battle Fogger User manual

LeMaitre
LeMaitre Show Mist Pro User manual

LeMaitre
LeMaitre LSX User manual

LeMaitre
LeMaitre Stage Fogger DMX User manual

LeMaitre
LeMaitre DMX Interface User manual

LeMaitre
LeMaitre TINY-FOGGER User manual

LeMaitre
LeMaitre G300 User manual