LG LA090HYV1 Installation and operation manual

3/4 and 1 Tons
Models:
LA090HYV1
LA120HYV1
SINGLE ZONE ART COOL™PREMIER
WALL MOUNTED ENGINEERING MANUAL

For continual product development, LG Electronics U.S.A., Inc., reserves the right to change specifications without notice.
© LG Electronics U.S.A., Inc.
PROPRIETARY DATA NOTICE
This document, as well as all reports, illustrations, data, information,
and other materials are the property of LG Electronics U.S.A., Inc., and are
disclosed by LG Electronics U.S.A., Inc. only in confidence.
This document is for design purposes only.
A summary list of safety precautions is on page 4.
For more technical materials such as submittals, catalogs, installation,
owner’s, and service manuals, visit www.lghvac.com.

Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. 3
Introduction
About LG Electronics, Inc.
LG Electronics, Inc. is a global leader and technology innovator
in consumer electronics, mobile communications, and home
appliances. LG Electronics, Inc. comprises five business units—
Home Entertainment, Mobile Communications, Air Conditioning,
Business Solutions, and Home Appliance. LG is one of the world’s
leading producers of flat panel televisions, audio and video products,
mobile handsets, air conditioners, and washing machines. LG’s
commercial air conditioning business unit was established in 1968
and has built its lineup of residential and commercial products to
include VRF, Multi F, duct-free split systems, packaged terminal air
conditioners (PTACs), and room air conditioners. In 2011, the air
conditioning and energy solutions business unit grew to include LED
lighting and solar products. For more information, visit www.lg.com.
Duct-Free Split Systems
LG HVAC systems offer a range of solutions that are cost efficient,
quiet and attractive. Duct-Free Split systems are “split” into indoor
and outdoor units, and provide a smart alternative to both central
HVAC and window-mounted air conditioners. These inverter heat
pump systems are available in a variety of configurations to suit dif-
ferent cooling and heating situations. Installation by a qualified HVAC
contractor is safe and easy – little to no duct work or sheet metal is
required.
Inverter Systems
LG Single Zone Art Cool™Premier Wall Mounted air-source systems
offer the opportunity to minimize ductwork in the same configuration.
The system offers zoning without the need for zone damper systems.
The LG Single Zone Art Cool™Premier system’s advanced controls
provide exceptional building dehumidification and temperature
control, and can rapidly adapt system operating parameters to the
ever changing building load. The LG Single Zone Art Cool™Premier
system is easy to design, install, and maintain. The modular design
allows occupants to control their environmental condition, providing
individualized control of the setpoint temperature and allowing oc-
cupants to condition only the occupied zones.
Quality Commitment
LG is committed to the success of Duct-Free Split projects. We
provide industry leading technical support during installation and
commissioning. LG offers a variety of classes designed for installers
and servicers to ensure that every system installation is completed
successfully.
Classes are conducted at LG’s training centers and in field locations
at various times throughout the year and upon special request.

Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
4
Art Cool™Mirror Wall Mounted Engineering Manual
TABLE OF CONTENTS
Introduction............................................................................................5
Architectural Appeal.............................................................................. 6
Product Features and Benets ............................................................8
Unit Nomenclature.................................................................................9
General Data ................................................................................... 10-11
Electrical Data...................................................................................... 12
Functions, Controls, and Options...................................................... 13
Outdoor Unit Dimensions LAU090HYV1, LAU120HYV1 .................. 14
Indoor Unit Dimensions LAN090HYV1, LAN120HYV1 ..................... 15
Acoustic Data.......................................................................................16
Refrigerant Flow Diagram................................................................... 18
Wiring Diagrams............................................................................. 19-20
LAN090HYV1, LAN120HYV1............................................................ 19
LAU090HYV1, LAU120HYV1............................................................ 20
Accessories .................................................................................... 21-23
Performance Data........................................................................... 25-28
Cooling Capacity ............................................................................... 26
Heating Capacity ............................................................................... 27
Air Flow and Temperature Distribution Graphs.................................. 28
Equipment Selection Procedure ........................................................ 30
Building Ventilation Design Guide..................................................... 31
Placement Considerations ............................................................ 32-34
Refrigerant Piping Design & Layout Best Practices ................... 38-43
Design Guideline Summary............................................................... 38
Selecting Field-Supplied Copper Tubing ........................................... 39
Refrigerant Piping System Layout..................................................... 40
Electrical Connections........................................................................44
Mechanical Specications.................................................................. 46
Acronyms............................................................................................. 47
TABLE OF SYMBOLS
This symbol indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
This symbol indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
This symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.
This symbol indicates situations that may result in equipment or property damage accidents only.
This symbol indicates an action should not be completed.
DANGER
CAUTION

INTRODUCTION
“Architectural Appeal” on page 6

Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
6|INTRODUCTION
Art Cool™Premier Wall Mounted Engineering Manual
Benefits of Single Zone
Art Cool Premier Wall-Mounted System
•Available in 9,000 and 12,000 Btu/h
•Inverter technology
•All-season use - heat pump models for both
cooling and heating capabilities
•Operating range for outdoor units of 14°F to
118°F (DB) in cooling and -13°F to 65°F (WB)
in heating
•Operating range for indoor units of 53°F to
75°F (WB) in cooling and 60°F to 86°F (DB)
in heating
•Quiet operation inside and outside
•Duct-free split system
Convergence of Technological Innovation with Flexibility and Style
Single Zone Art Cool
Premier Wall-Mounted
Systems
Choosing an LG Single-Zone Art Cool
Premier Wall-Mounted product provides
a system designer an edge to engineer
a system with individual control, and
design flexibility with advanced controls.
These single-zone systems are avail-
able in a nominal capacities of 3/4 and 1
tons. These are best suited for applica-
tions with zones that require heating or
cooling, such as residential, and small
business office buildings. Single-Zone
Art Cool Premier Wall-Mounted out-
door and indoor units are available in
208–230V/60Hz/1Ph.
Adaptable and Flexible
Single-zone wall-mounted duct-free split
systems allow cooling or heating for the
entire residence or just a single room
without the need for invasive ductwork.
There is minimal renovation needed.
Long refrigerant piping lengths allow
for extra design flexibility in indoor unit
installation.
These units may be used for a number of
residential or commercial environments
such as:
•Older homes
•New home construction
•Office buildings
•Restaurants
•Hospitals / Medical facilities
•Schools
•Nursing homes
•Retail establishments
•House of worship
Inverter Technology
Inverter variable-speed duct-free split
systems are measurably quieter and
consume less energy than conventional
air conditioners. The inverter compressor
ramps up or down to match the required
room capacity and maintain the comfort
level. When the selected temperature
is reached, the inverter compressor
operates at low speed to maintain that
comfort level, thereby using less energy.
ARCHITECTURAL APPEAL

PRODUCT DATA
“Product Features and Benefits” on page 8
“Unit Nomenclature” on page 9
“General Data” on page 10
“Electrical Data” on page 12
“Functions, Controls, Options” on page 13
“Outdoor Unit Dimensions” on page 14
“Indoor Unit Dimensions” on page 15
“Acoustic Data” on page 16
“Refrigerant Flow Diagram” on page 18
“Indoor Unit Wiring Diagram” on page 19
“Outdoor Unit Wiring Diagram” on page 20
“Accessories” on page 21

8|PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
PRODUCT FEATURES AND BENEFITS
Single Zone Art Cool™
Premier Wall Mount
Single zone systems are equipped with
inverter components that offer superior
load matching and long piping installation.
The product works for optimizing power
consumption in residential and small office
buildings. Utilizing multiple indoor wall mount
units each with custom temperature controls
allow for precise temperature settings in
each zone of the building. Single zone sys-
tems allow flexibility in interior design and
complement any decor.
Low Sound Levels
When outdoor units run at full load, they
have a quiet operating sound level. To
promote a quiet, comfortable environment,
the LG single zone system indoor units
operate at sound levels as low as 25 dB(A)
(17 dB(A) in sleep mode) (Art Cool Premier)
and the outdoor units as low as 45 dB(A)
at full load (Art Cool Premier). All rotating
components are soft-started by the control-
ler using digitally controlled inverters, which
reduce undesirable noise caused by fans
and compressors cycling on and off.
Comfort Control at Its
Best
Unlike traditional air conditioning control
systems, which use thermostatic controls to
maintain room temperatures, LG single zone
inverter controls continuously vary the indoor
unit fan speed and refrigerant flow.
LG single zone one-to-one systems continu-
ously measure the room temperatures and
adjust system operations accordingly to
maintain set temperature.
The outdoor unit responds by varying the
compressor speed and outdoor fan mo-
tors as needed to maintain system operat-
ing pressure. As a result, the single zone
systems deliver targeted space temperature
control.
Inverter Driven
The twin rotary compressors are optimized
to maximize compressor efficiency, which re-
duces power consumption and monthly utility
bills. This latest inverter technology allows
single zone system outdoor units to vary the
compressor motor shaft speed to deliver an
appropriate amount of cooling to the indoor
unit. Precise refrigerant volume delivery
translates into long periods with coil surface
temperatures below dew point and minimiz-
es compressor and fan component run time
which may lead to lower utility usage.
Simplified Installation
Cooling and heating applications that use
single zone systems simplify and reduce the
mechanical and control system design time.
The designer no longer has to be concerned
with interconnecting chilled and condenser
water piping, air-distribution duct systems,
matching and selecting chillers, towers,
pumps, coils, fans, air handlers, or Variable
Air Volume (VAV) boxes.
Operating Range
Single zone systems have a nominal capac-
ity range of 3/4 and 1 tons (depending on
outdoor/indoor units).
Outdoor unit operating ranges for single
zone systems:
Cooling: 14°F DB to 118°F DB
Heating: -13°F WB to 65°F WB
Compact Size
Single zone outdoor units have the following
footprint:
LAU090HYV1, LAU120HYV1
(WxHxD (in)) 30 5/16 x 21-1/2 x 11-5/16.
Fin Design with Gold-
Fin™ Coating
All single zone outdoor units are provided
with large surface coils made of copper
tubes with louvered aluminum fins designed
to maximize unit operating efficiency over a
wide range of ambient conditions.
Standard from the factory, every single
zone outdoor unit coil fin surface is
coated with LG’s exclusive GoldFin™
anti-corrosive coating designed to prevent
natural surface corrosion of the alumi-
num fins. This maintains heat transfer
properties of the coil for an extended time.
A hydrophilic coating is applied to the
outdoor unit coil fin surface over the GoldFin
coating. This coating enhances the develop-
ment of heavier water droplets gathering on
the fin surface. As a result, the droplets roll
off the fin surfaces, delaying the point when
frost forms on the coil surface during heat-
ing operation. This coating also makes it
possible to easily clean the outdoor unit coil
using a mild soap.
Other Features
•Inverter variable speed compressor
•Jet Cool / Jet Heat
•Dehumidifying mode
•3M™Micro Protection Filter
•Auto Wind
•Auto restart
•Auto operation
•Self-cleaning indoor coil
•Condensate sensor connection
•Works with Smart AC
•Precision load matching
•Meets AHRI 210/240

PRODUCT DATA | 9
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
UNIT NOMENCLATURE
Single Zone Wall Mount Indoor and Outdoor Units
LA N090 HSV 4
Type
N = Indoor Wall Mount Unit
U = Outdoor Heat Pump Unit
Family
LA= Art Cool Premier / Gallery / Mirror
LS= High Efficiency Wall Mount / Standard / Mega
Generation or Revision
1 = First
2 = Second
3 = Third
4 = Fourth
Nominal Capacity
(Nominal cooling capacity in Btu/h)
090/091 = 9,000
120/121 = 12,000
180/181 = 18,000
240 = 24,000
300/307 = 30,000
360 = 36,000
Indoor/Outdoor Product
HEV = Mega
HXV = Mega 115V
HYV = Art Cool Premier
HVP = Art Cool Gallery
HSV = Art Cool Mirror, High Efficiency
HV = Standard
HLV = Extended Pipe

10 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
GENERAL DATA
Art Cool Premier Pairing Table
The following table shows the available outdoor and indoor units, along with the factory provided controller.
Table 1: Single Zone Art Cool Premier Pairing Table
Outdoor Unit Model Indoor Unit Model Controller
LAU090HYV1
LAU120HYV1
LAN090HYV1
LAN120HYV1
AKB73835320

PRODUCT DATA | 11
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
GENERAL DATA
Table 2: SingleZoneArtCoolPremierSystemSpecications.
System Model Number (IDU/ODU) LA090HYV1
(LAN090HYV1/LAU090HYV1) LA120HYV1
(LAN120HYV1/LAU120HYV1)
Cooling Capacity (Min/Rated/Max) (Btu/h) 1,023 ~ 9,000 ~ 12,966 1,023 ~ 11,000 ~ 13,785
Cooling Power Input1(kW) 0.575 0.80
Heating Capacity (Min/Rated/Max) (Btu/h) 1,023 ~ 11,000 ~ 20,472 1,023 ~ 12,000 ~ 22,178
Heating Power Input1(kW) 0.71 0.75
COP 4.54 4.68
Maximum Heating Capacity (Btu/h)
Outdoor 17°F (WB)/Indoor 70°F (DB) 11,935 (109%) 14,650 (122%)
Outdoor 5°F (WB)/Indoor 70°F (DB) 11,220 (102%) 13,720 (114%)
Outdoor -13 °F (WB)/Indoor 70°F (DB) 7,920 (72%) 9,520 (79%)
EER 15.65 13.75
SEER 27.5 25.5
HSPF 12.0 12.0
Power Supply (V/Hz/Ø) 208-230/60/1
Outdoor Unit Operating Range
Cooling (°F DB) 14 to 118
Heating (°F WB) -13 to 65
Indoor Unit Operating Range
Cooling (°F WB) 53 to 75
Heating (°F DB) 60 to 86
Indoor Temperature Setting Range
Cooling (°F) 64 to 86
Heating (°F) 60 to 86
Unit Data
Refrigerant Type2R410A
Refrigerant Control EEV
IDU Sound Pressure3dB(A) (H/M/L/Sleep) 42/36/25/17 42/36/25/17
ODU Sound Pressure3dB(A) 45 45
Unit Weight (lbs)
IDU (Net/Shipping) 24/30 24/30
ODU (Net/Shipping) 77/82 77/82
Power/Communication Cable4 (No. x AWG) 4 x 18
Compressor
Compressor Type (Qty) Twin Rotary (1) Twin Rotary (1)
Fan
IDU Type (Qty) Cross Flow (1)
ODU Type (Qty) Propeller (1)
Motor/Drive Brushless Digitally Controlled/Direct
Airflow Rate
IDU Max/H/M/L (CFM) 547/494/417/283 547/494/417/283
ODU Max (CFM) 1,165 1,165
Piping
Liquid Line (in, OD) 1/4 1/4
Vapor Line (in, OD) 3/8 3/8
Condensation Line (OD, ID) 27/32, 5/8 27/32, 5/8
Additional Refrigerant Charge (oz/ft) 0.22 0.22
Pipe Length5(Minimum/Maximum)(ft) 6.6/65.6 6.6/65.6
Piping Length5(no add’l refrigerant, ft) 41.0 41.0
Max Elevation Difference (ft) 32.8 32.8
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit
1Power Input is rated at high speed.
2Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A
refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
3Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4All power wiring/communication cables are field supplied and are to be minimum 18 AWG, 4-conductor,
stranded, shielded and must comply with applicable local and national codes.
5Piping lengths are equivalent.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

12 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Model Number Nominal Tons Compressor
Qty.
Compressor (A)
Cool/Heat Fan Qty. ODU Fan (A) IDU Fan (A) MCA(A) MOP(A)
LA090HYV1 3/4 1 8.3/8.3 1 0.40 0.40 11.2 15
LA120HYV1 1 1 8.3/8.3 1 0.40 0.40 11.2 15
Table 3: Single-Zone Art Cool Premier System Electrical Data Table.
Voltage tolerance is ±10%.
Maximum allowable voltage unbalance is 2%.
MCA = Minimum Circuit Ampacity.
Maximum Overcurrent Protection (MOP) is calculated as follows: (Largest motor FLA x 2.25) + (Sum of
other motor FLA) rounded down to the nearest standard fuse size.
ELECTRICAL DATA

PRODUCT DATA | 13
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
FUNCTIONS, CONTROLS, OPTIONS
Table 4: Indoor Units—Functions, Controls and Options.
Indoor Unit Type LA090HYV1 LA120HYV1
Airow
Air supply outlet 1 1
Airflow direction (left/right) Auto Auto
Airflow direction (up/down) Auto Auto
Auto swing (left/right) √ √
Auto swing (up/down) √ √
Airflow steps (fan/cool/heat) 6 / 6 / 6 6 / 6 / 6
Auto swing √ √
Auto wind √ √
Jet-cool/heat √/√ √/√
Swirl wind X X
One touch soft air √ √
Air Purifying
Washable anti-fungal1√ √
Deodorizing filter X X
Plasma2X X
Allergy free filter X X
3M Micro Protection filter2√ √
Functions
Drain pump X X
E.S.P. control X X
Electric heater X X
High ceiling X X
Defrost √ √
Low ambient √ √
Hot start √ √
Self diagnostics √ √
Soft dry (dehumidification) √ √
Auto changeover √ √
Auto clean (coil dry) √ √
Auto restart √ √
Child lock X X
Forced operation √ √
Sleep mode √ √
Timer (24hr on/off) √ √
Weekly timer X X
Two thermistor control X X
Controllers
Wireless Remote Controller √ √
Simple Controller with Mode Selection o o
Simple Controller without Mode Selection o o
LG Programmable Thermostat o o
Dry contact o o
Central control (LGAP) X X
PI 485 X X
Special Function Kit
Zone control X X
CTIE X X
Electro thermostat X X
Wi-Fi Module (Option) o o
Water level sensor connection (for optional AG-9300-LG) o o
Wind baffle kit X X
Other
Thermistor X X
1Primary washable filters.
2Secondary filters.
√=Standardfeature
o = Optional accessory (must be purchased separately)
X = Not available
•WhenDryContactModeactive,Wi-FiFunctioncannotbeused.
•WhenchangingfromWi-Fimodetodrycontactmode,normaloperationresumesinapproximately3minutes.

14 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
LAU090HYV1, LAU120HYV1
OUTDOOR UNIT DIMENSIONS
Center of gravit y
Unit: Inch
30-5/16
22 4-3/16
13-15/16
6-1/8
2-1/8
10-15/16 1
20-15/16
21-1/2
10-1/2
9-3/8
20
2-13/16
8-1/8
4
3
2
5
11 -5/16
5-3/4
Ø18-5/16
Ground Terminal

PRODUCT DATA | 15
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
INDOOR UNIT DIMENSIONS
LAN090HYV1, LAN120HYV1
Ø2-9/16
4-13/16
6-11/16
Right rear piping
Left rear piping
Place a level on raised tab
Unit Outline
8-9/16
6-15/16
17 17-5/16
5
Ø2-9/16
34-7/16 9-1/4
11-5/8
3
2
2-3/16
1
2
2
2-3/16
4
Unit: Inch
for piping and cable

16 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Model Sound Pressure Levels (dB[A])
Cooling (Max) Heating (Max.)
LAU090HYV1 45 45
LAU120HYV1 45 45
Table 5: Outdoor Unit Acoustic Data
Figure 1: Outdoor Unit Sound Levels
3.28 ft
Center of
Outdoor Unit
Figure 2: Sound Pressure Levels for LAU090-120HYV1 Outdoor Units.
•Measurements are taken 3.28 ft away from the front of the unit.
•Sound pressure levels are measured in dB(A) with a tolerance of
±3.
•Sound pressure levels are tested in an anechoic chamber under
ISO Standard 3745.
•Sound level will vary depending on a range of factors including the
construction (acoustic absorption coefficient) of a particular room in
which the unit was installed.
OUTDOOR UNIT ACOUSTIC DATA
Octave Band Center Frequency (Hz)
Octave Band Sound ressure Level (0dB = 20μPa)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Octave Band Sound Pressure Level (dB re 20µPa )
Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
LAU090HYV1 LAU120HYV1

PRODUCT DATA | 17
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Figure 3: Indoor Unit Sound Levels
2.62 ft
3.28 ft
Microphone
Model
Sound Pressure Levels (dB[A])
Cooling Heating
H M L H M L
LAN090HYV1 42 36 25 42 36 25
LAN120HYV1 42 36 25 42 36 25
Table 6: Indoor Unit Acoustic Data
Figure 4: Sound Pressure Levels for LAN90-120HYV1 Indoor Units.
•Measurements are taken 3.28 ft away from the front of the unit.
•Sound pressure levels are measured in dB(A) with a tolerance of ±3.
•Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
•Sound level will vary depending on a range of factors including the construction (acoustic absorp-
tion coefficient) of a particular room in which the unit was installed.
INDOOR UNIT ACOUSTIC DATA
Octave Band Sound Pressure Level (0dB = 20μPa)
Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125250 5001000200040008000
NC-15
NC-20
NC-25
NC-30
NC-35
NC-40
NC-45
NC-50
NC-55
NC-60
NC-65
Approximate
Hearing
Threshold
Octave Band Sound Pressure Level (dB re 20µPa )
Octave Band Center Frequency (Hz)
10
20
30
40
50
60
70
80
63 125 250 500 1000 2000 4000 8000
LAN090HYV1 LAN120HYV1

18 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
REFRIGERANT FLOW DIAGRAMS
LAU/LAN090HYV1, LAU/LAN120HYV1
Thermistor Description PCB Connector
TH1 Indoor air temperature thermistor CN-TH1 (Indoor)
TH2 Water level sensor (optional) CN-TH2 (Indoor)
TH3 Evaporator middle temperature thermistor CN-TH3 (Indoor)
TH4 Condensing temperature thermistor CN-TH1 (Outdoor)
TH5 Outdoor air temperature thermistor
TH6 Discharge pipe temperature thermistor CN-TH2 (Outdoor)
FIELD PIPING
(Ø1/ 4” Copper Tubing)
FI ELD PIPING
(Ø 3/ 8” Copper Tubing)
M
M
Heat
Exchanger
(Evaporator)
He at
Exchanger
(Condenser)
Compressor
Accumulator
2-Way Valve
Reversing
Valv e
Indoor Unit Outdoor Unit
: Cooling
: Heating
EEV
TH1
TH3
TH2
TH5
TH6
TH4
Liquid Side
Gas Side
3-
Way Valv e

PRODUCT DATA | 19
Product Data
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
WIRING DIAGRAM
LAN090HYV1, LAN120HYV1

20 |PRODUCT DATA
Art Cool™Premier Wall Mounted Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
WIRING DIAGRAM
LAU090HYV1, LAU120HYV1
This manual suits for next models
1
Table of contents
Other LG Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Gree
Gree GKHD(12)ABND3A2AI Service manual

AirStage
AirStage ASUA7RLAV installation manual

Mitsubishi Electric
Mitsubishi Electric PLA-SP BA Series Operation manual

Hitachi
Hitachi RA-13JF1 Operation and installation manual

Diplomat
Diplomat DX-80CHRC instruction manual

Carrier
Carrier 42TOVG010 owner's manual