LifeSafety Power NETPOWER NPM115 User manual

LifeSafety Power, Inc. | PH 888.577.2898 | TechSupport@LifeSafetyPower.com
P03-028 Rev A05
NPM Installation Manual
NETPOWER
managed multiport poe+ midspan injectors
®

NPM Installation Manual
2 3
Description
The LifeSafety Power NPM line of PoE MidSpan Injec-
tors are available at 15.5W (IEEE 802.3af) and 30W (IEEE
802.3at).
The NPM MidSpan Injectors provides PoE compliant power
to PoE compatible devices such as IP cameras, IR illumina-
tors, access control panels and readers, or to non-PoE de-
vices using a PoE Extractor such as the NetPower NPE130.
Regulatory Information
The equipment discussed within this manual has been tested
to the following standards:
• UL294b
• UL/CUL 60950-1
• CSA C22.2 No. 205-M1983
Mounting the NPM Series Module
The NetPower NPM Midspan Injectors mount using two
screws in the mounting tabs. The NPM is also available in
a DIN Rail mountable version. The unit must be mounted
in a secure, indoor, dry location to a suitable surface, using
suitable hardware.
Data PoE/Data
Port
Status
24V AC/DC
Input
PoE
Shutdown
#6 Diameter
3.85”
Specifications
NPM115 NPM130
Input Voltage 24VAC or 24VDC ±15% 24VAC or 24VDC ±15%
Input Current 1.4A Max. AC or DC 2.6A Max. AC or DC
Output Power 15.4W (IEEE802.3af) 30W (IEEE802.3at)
Output Voltage 50VDC 50VDC
Output Current 300mA 600mA
Shutdown Terminals 5-24VDC @ 10mA Max. 5-24VDC @ 10mA Max.
Data Cable Length 328 ft (100 m) Max. 328 ft (100 m) Max.
Data Rate 10/100 Base-T 10/100/1000 Base-T
ESD Immunity 8kV 8kV
PoE Pin Assignment Positive (VCC+): Pins 4, 5 Positive (VCC+): Pins 4, 5
Negative (VCC–): Pins 7, 8 Negative (VCC–): Pins 7, 8
Data: Pins 1, 2, 3, 6 Data: Pins 1, 2, 3, 4, 5, 6, 7
Operating Ambient Temperature 0 to 49°C, Indoor Dry Locations 0 to 49°C, Indoor Dry Locations
Storage Temperature –20 to +70°C –20 to +70°C
Operating Humidity 5 to 95% (Non-Condensing) 5 to 95% (Non-Condensing)
Size 4.20" L x 2.50" W x 1.20" D
(107mm L x 64mm W x 31mm D) 4.20" L x 2.50" W x 1.20" D
(107mm L x 64mm W x 31mm D)
Weight 0.25 lb (0.11 kG) 0.30 lb (0.14 kG)

NPM Installation Manual
2 3
NPM115/130 – Module Overview
1
Data
This is the non-PoE input from the network switch. This con-
nector is an RJ45 jack and accepts a CAT-5 cable.
2
PoE/Data
This is the PoE output to the camera or other device to be
powered. See the Specifications section for ratings. This
connector is an RJ45 jack and accepts a CAT-5 cable.
3
Port Status (Green)
This LED shows the status of the NetPower MidSpan Injector.
See the appropriate status chart for more information.
4
PoE Shutdown
This input will shut down the PoE output of the NetPower
MidSpan Injector. This can be useful for rebooting devices
that have become non-responsive. These terminal strips
accept wire sizes from AWG14 - AWG22. To shut down the
PoE Output, apply any DC voltage within the ratings shown under
"Shutdown Terminals" in the Specifications section of this manual.
5
Mounting Tab
The mounting tab centers are spaced 3.85" on center. Refer to
the mounting guide (page 1) for mounting details.
6
24VAC or 24VDC Input
This is the power supply input for the NetPower MidSpan Injector.
These terminal strips accept wire sizes from AWG14 - AWG22.
See the Specifications section for more information. When using
DC voltage, the voltage may be connected in either polarity.
NPM115 / 130 - Status LED
NPM115 Port Status LED State Flash Pattern
No Primary Power to Unit OFF LED OFF
No Connection on PoE/Data Port OFF LED OFF
Operation Normal ON LED ON
Improper Load Device 1 Flash R l l l R l l l R l l l
Improper Load Device 2 Flashes R R l l R R l l R R l l
Port Overload Fault 5 Flashes l l l l R R R R R l l l l
NPM130 Port Status LED State Flash Pattern
No Primary Power to Unit OFF LED OFF
No Connection on PoE/Data Port OFF LED OFF
Operation Normal ON LED ON
Improper Load Device 5 Flashes l l l l R R R R R l l l l
Port Overload Fault 2 Flashes R R l l R R l l R R l l
Data PoE/Data
Port
Status
24V AC/DC
Input
PoE
Shutdown

NPM Installation Manual
4 5
Example Wiring - Block Diagrams
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
Power Shutdown
Input
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
IP Camera
NetPower MidSpan
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
Power Shutdown
Input
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
PoE Camera
PoE Compliant
Reader
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
b) Powering a PoE Camera
c) Power & Data for a non-PoE IP Camera
a) Powering a PoE Reader
Port
Status
24V AC/DC
Input
PoE
Shutdown
Data PoE/Data
NPM115/130
NetPower
MidSpan
Port
Status
24V AC/DC
Input
PoE
Shutdown
Data PoE/Data
NPM115/130
NetPower
MidSpan
Port
Status
24V AC/DC
Input
PoE
Shutdown
Data PoE/Data
NPM115/130
NetPower
MidSpan
Data PoE/Data
Output
Status
12VDC
+ –
NPE130
NetPower
Extractor

NPM Installation Manual
4 5
Example Wiring - Block Diagrams (continued)
Access Control
Edge Controller
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
Mag Lock
Reader Magnetic Contact
f) Powering a PoE Access Controller with NPM130
Data PoE/Data
Output
Status
12VDC
+ –
POE Camera
NPE130
NetPower
Extractor
NetPower MidSpan
Port
Status
24V AC/DC
Input
PoE
Shutdown
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
Power Shutdown
Input
Data PoE/Data
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
IR Illuminator
Y
Connector
NPM115/30
NetPower
MidSpan
Port
Status
24V AC/DC
Input
PoE
Shutdown
Data PoE/Data
NPM130
NetPower
MidSpan
e) Power & Data for PoE Camera and non-PoE IR Illuminator
IP Camera
NetPower MidSpan
24VAC/VDC
Input PoE
Shutdown PoE/Data Data
Power Shutdown
Input
24V DC from
FPO
Power Supply
or 24V AC
Network Switch
d) Power & Data for a non-PoE IP Camera and Illuminator
Port
Status
24V AC/DC
Input
PoE
Shutdown
Data PoE/Data
NPM115/130
NetPower
MidSpan
IR Illuminator
Data PoE/Data
Output
Status
12VDC
+ –
NPE130
NetPower
Extractor

NPM Installation Manual
6 PB
Section
P03-028 Rev A05 10/16
Important: All information, including illustrations, is believed to be reliable. Users, however, should independently
evaluate the suitability of each product for their particular application. LifeSafety Power makes no warranties as to the
accuracy or completeness of the information, and disclaims any liability regarding its use. LifeSafety Power’s only ob-
ligations are those in the LifeSafety Power Standard Terms and Conditions of Sale for this product, and in no case will
LifeSafety Power or its distributors be liable for any incidental, indirect, or consequential damages arising from the
sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, LifeSafety
Power reserves the right to make changes—without notification to Buyer—to processing or materials that do not affect
compliance with any applicable specification.
LifeSafety Power, FlexPower, NetLink, GreenSmart, FlexConnect, PowerCom, Reliability+, SureCharge, TruWatt, and VSelect are
trademarks or registered trademarks of LifeSafety Power Inc. or its affiliates.
© 2016 LifeSafety Power, Inc.All rights reserved
LifeSafety Power Inc.
304 Terrace Drive
Mundelein, IL 60060 USA
www.lifesafetypower.com
Tel (888) 577-2898
info@lifesafetypower.com