INSTALLATION GUIDE
RWL II Series
LED Street Lighting
RISK OF ELECTRIC SHOCK
• Installation must be done by a certified electrician and / or qualified personnel.
• Make sure to turn OFF the main power from the circuit breaker or fuse box before installing, servicing
or inspecting this fixture.
• Make sure all grounding wires are connected correctly.
WARNING
RISK OF FIRE
• Ensure that all line voltage wire is intended for specified product wattage.
• Use UL and / or CE approved wires for all input connections, minimum size required 18 AWG (0.82mm²)
• Do not use this product in environments where the temperatures could exceed 55°C (131°F)
NOTE
• While the fixture is ON, do not cover the front surface of the
light fixture or place it on any flat surfaces that would cover
the front air ventilation holes for more than 30 minutes.
This will prevent the fixture from properly cooling via air
convection and can cause the fixture to overheat & fail.
* BEFORE YOU INSTALL this fixture please read these instructions carefully and completely
Dimming
Dim – (Brown)
NOTE: • Ensure that all line voltage wire is intended for specified
product wattage.
• Use UL and / or CE approved wires for all input connections,
minimum size required 18 AWG (0.82mm²)
• Refer to the specific dimmer installation manual for exact
wiring instructions.
N– (White)
L– (Black)
Ground (Green)
Dim + (Blue)
AC Input
Wiring Information
www.lightemittingdesigns.com
2140 N. Hollywood Way #6486 Burbank, CA 91510 USA
06
RWLII IG REV01012022
Roadway Pole Mount