Calculite® Evolution Glasslite Downlight C3MRGD
Page 1 of 2 3" Aperture, MR16 (12V)
Spec. Sheet
C3MRGD
1/2"
(13mm)
2" (59mm) Max.
Ceiling Thk.
2 3/4" (70mm) Dia.
4" (102mm) Dia.
C3LV
Vertical Adjustment
1" (25mm) to
2 3/4" (70mm)
9 1/2"
(242mm)
9"
(229mm)
1/2" (13mm) C3AICLV
10 4
1
23 67985
5 1/2"
(140mm)
5"
(127mm)
Plus Ceiling
Thk.
5" (127mm)
12 5/8"
(321mm)
14 3/8"
(365mm)
9 5/8"
(245mm)
5" (127mm)
14 3/8"
(365mm)
10 1/8"
(257mm)
9" (229mm)
11 3/16"
(284mm)
22 3/8"
(568mm)
Non-IC:
C3LV
C3LVE1
C3LVE2
Non-IC AirSeal:
C3ALV
C3ALVE1 C3ALVE2
IC AirSeal:
C3AICLV C3AICLVE1
14 5/8"
(372mm)
Spec. Sheet
C3MRGD
IC AirSeal Frame:
C3AICLV
C3ALCLVE1
Features
1. Glasslite: One piece borosilicate glass with interal flange, etched interior
and white ceramic coated exterior. Etched white cone finish emits a subtie
glow. Hinged, and snaps on for easy tool-less installation. Interchangeable
with other 3" Evolution trims. Suitable for shower and other wet environments.
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping
during relamping. Spring tension clips hold lamp and lens and allow fast
snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diameter
accessories.
3. Cover Glass: High temperature, clear lens.
4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust
trim kit vertically to accommodate up to 2" thick ceiling, lockable.
5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads.
6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim, matte
black finish.
7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mounting
to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT
tubing (by others). Single locking features secures all adjustments. Alignment
holes and markings allow fixture to be pre-set prior to installation. Final
adjustment can be made from below inside fixture.
8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping
bars extend from 20" to 30" long and lock securely into position. Built-in locking
tabs provide positive attachment to common T-bar systems. Self-centering
feature simplified installation in 24"O.C. grid systems. Attaches to steel or
wood joists without accessories.
9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual-
voltage, core & coil. Note: Magnetic not recommended for residential or noise
sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp
voltage, HPF, , EMI and circuit protections, thermal auto-reset, quiet operation.
10. Frame-In Kit: See Frame-In Kit specification sheets for more information.
Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts of
the luminaire and must not be placed above luminaire in a manner which will
entrap heat.
IC AirSeal - Luminaire may be in direct contact with thermal insulation.
Labels
U.L. (Suitable For Wet Locations), I.B.E.W.
*Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W
for ceiling thickness greater than 1" (up to 2").
Options and Accessories
2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets
2" dia. Louver: AL2HC
Chicago Plenum: Consult Factory
Ceiling Cutout: 3 1/2" (130mm) Dia.
For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.
Trim Kit Frame-In Kit Lamp*
Etch White Glasslite C3MRGD
C3LV Non-IC Magnetic 120/277V 42W-65W MR16 (12V)
C3LVE1 Non-IC Electronic 120V 20W-65W MR16 (12V)
C3LVE2 Non-IC Electronic 277V 20W-65W MR16 (12V)
C3ALV Non-IC AirSeal®Magnetic 120/277V 42W-65W MR16 (12V)
C3ALVE1 Non-IC AirSeal®Electronic 120V 20W-65W MR16 (12V)
C3ALVE2 Non-IC AirSeal®Electronic 277V 20W-65W MR16 (12V)
C3AICLV IC AirSeal®Magnetic 120V 20W-50W MR16 (12V)
C3AICLVE1 IC AirSeal®Electronic 120V 20W-50W MR16 (12V)
Note: Magnetic not recommended for residential or noise sensitive areas.
Non-IC Frame:
C3LV
C3LVE1
C3LVE2
Non-IC AirSeal Frame:
C3ALV
C3ALVE1
C3ALVE2
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • E0711
Job Information Type:
Calculite® Evolution Glasslite Downlight C3MRGD
Page 2 of 2 3" Aperture, MR16 (12V)
Spec. Sheet
C3MRGD
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 5551
5 3854 345
10 1184
15 310 138
20 141
25 48 30
30 22
35 8 7
40 5
45 2 2
50 1
55 2 1
60 1
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 - 15° SPOT GE HALOGEN LAMP, LUMEN RATING = 750 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 640
55 750
65 104
75 170
85 0
** EFFICIENCY = 69.7% ** CERTIFIED TEST REPORT NO. 2724FR DATE: SEP 7, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .83 .83 .83 .83 .81 .81 .77 .77 .74 .74 .70
1 .81 .80 .79 .78 .79 .77 .76 .75 .73 .73 .69
2 .79 .79 .76 .75 .76 .74 .74 .73 .73 .71 .69
3 .78 .76 .74 .73 .75 .72 .73 .71 .72 .70 .68
4 .77 .74 .72 .71 .74 .70 .72 .70 .71 .69 .68
5 .75 .73 .71 .69 .72 .69 .71 .69 .70 .68 .67
6 .74 .72 .70 .68 .71 .68 .70 .68 .70 .67 .66
7 .73 .71 .69 .67 .70 .67 .69 .67 .69 .66 .66
8 .73 .70 .68 .67 .69 .66 .69 .66 .68 .66 .65
9 .72 .69 .67 .66 .68 .66 .68 .65 .68 .65 .65
10 .71 .68 .66 .65 .68 .65 .67 .65 .67 .65 .64
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .2
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 512 68.32 97.99
0-40 518 66.20 99.25
0-60 522 69.64 99.89
0-90 522 69.72 100.00
40-90 3 0.52 0.75
60-90 0 0.08 0.11
90-180 0 0.00 0.00
0-180 522 69.72 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1816
5 1629 150
10 1213
15 792 231
20 460
25 194 107
30 74
35 27 21
40 8
45 5 4
50 4
55 3 3
60 3
65 2 2
70 2
75 1 1
80 1
85 0 0
90 0
50W MR16 - 25° NARROW FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1483
55 1270
65 1241
75 1079
85 351
** EFFICIENCY = 65.1% ** CERTIFIED TEST REPORT NO. 2817FR DATE: SEP 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .77 .77 .77 .77 .76 .76 .72 .72 .69 .69 .65
1 .75 .74 .73 .72 .73 .71 .70 .69 .68 .67 .64
2 .73 .71 .70 .68 .70 .67 .68 .66 .66 .64 .62
3 .71 .69 .67 .65 .68 .65 .66 .64 .65 .63 .61
4 .70 .67 .64 .63 .66 .62 .65 .62 .64 .61 .60
5 .68 .65 .62 .60 .64 .60 .63 .60 .62 .59 .58
6 .66 .63 .61 .59 .62 .59 .62 .58 .61 .58 .57
7 .65 .61 .59 .57 .61 .57 .60 .57 .59 .56 .56
8 .63 .60 .57 .56 .59 .56 .59 .55 .58 .55 .54
9 .62 .58 .56 .54 .58 .54 .57 .54 .57 .54 .53
10 .61 .57 .55 .53 .57 .53 .56 .53 .56 .53 .52
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .5
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 487 60.97 93.72
0-40 509 63.64 97.83
0-60 516 64.55 99.23
0-90 520 65.05 100.00
40-90 11 1.41 2.17
60-90 4 0.50 0.77
90-180 0 0.00 0.00
0-180 520 65.05 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
ANGLE MEAN CP
LUMENS
0 1425
5 1388 130
10 1256
15 1006 275
20 616
25 182 118
30 42
35 17 13
40 8
45 4 3
50 3
55 2 2
60 2
65 1 1
70 0
75 0 0
80 0
85 0 0
90 0
50W MR16 - 40° FLOOD GE HALOGEN LAMP, LUMEN RATING = 800 LMS, 120V ELECTRONIC TRANSFORMER
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1164
55 864
65 616
75 0
85 0
** EFFICIENCY = 68% ** CERTIFIED TEST REPORT NO. 2722FR DATE: SEP 5, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .81 .81 .81 .81 .79 .79 .76 .76 .72 .72 .66
1 .79 .78 .77 .75 .76 .74 .73 .72 .71 .70 .67
2 .76 .75 .73. 71 .73 .71 .71 .69 .69 .68 .65
3 .75 .72 .70 .68 .71 .68 .70 .67 .68 .66 .64
4 .73 .70 .68 .66 .69 .66 .68 .65 .67 .64 .63
5 .71 .68 .65 .64 .67 .63 .66 .63 .65 .62 .61
6 .70 .66 .64 .62 .66 .62 .65 .62 .64 .61 .60
7 .68 .64 .62 .60 .64 .60 .63 .60 .63 .60 .59
8 .67 .63 .60 .59 .62 .59 .62 .58 .61 .58 .57
9 .65 .61 .59 .57 .61 .57 .60 .57 .60 .57 .56
10 .64 .60 .58 .56 .60 .56 .59 .56 .59 .56 .55
LUMINAIRE INPUT WATTS = 51
Coefficients of Utilization
SC = .6
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 523 65.48 96.34
0-40 537 67.14 98.77
0-60 542 67.82 98.77
0-90 543 67.97 100.00
40-90 6 0.83 1.23
60-90 1 0.16 0.23
90-180 0 0.00 0.00
0-180 543 67.97 100.00
30˚
60˚
500˚
1000˚
1500˚
2000˚
30˚
60˚
1400˚
2800˚
4200˚
5600˚
30˚
60˚
375˚
750˚
1125˚
1500˚

Other Lightolier Light Fixture manuals

Lightolier Lytespan 8330 User manual

Lightolier

Lightolier Lytespan 8330 User manual

Lightolier Lytespan 6276B User manual

Lightolier

Lightolier Lytespan 6276B User manual

Lightolier B16 series User manual

Lightolier

Lightolier B16 series User manual

Lightolier ProSpec 26690 User manual

Lightolier

Lightolier ProSpec 26690 User manual

Lightolier SL205B User manual

Lightolier

Lightolier SL205B User manual

Lightolier Lytecaster 1182 User manual

Lightolier

Lightolier Lytecaster 1182 User manual

Lightolier 4R28 User manual

Lightolier

Lightolier 4R28 User manual

Lightolier 1101FIC User manual

Lightolier

Lightolier 1101FIC User manual

Lightolier Lytespan 8171WH User manual

Lightolier

Lightolier Lytespan 8171WH User manual

Lightolier Skyway SKSGPK232 User manual

Lightolier

Lightolier Skyway SKSGPK232 User manual

Lightolier Calculite ProSpec PA3H3039 User manual

Lightolier

Lightolier Calculite ProSpec PA3H3039 User manual

Lightolier ProSpec DRP16 User manual

Lightolier

Lightolier ProSpec DRP16 User manual

Lightolier Calculite 8081 User manual

Lightolier

Lightolier Calculite 8081 User manual

Lightolier ProSpec 26030 User manual

Lightolier

Lightolier ProSpec 26030 User manual

Lightolier SL301A User manual

Lightolier

Lightolier SL301A User manual

Lightolier MR-16 User manual

Lightolier

Lightolier MR-16 User manual

Lightolier Lytespan 8113 User manual

Lightolier

Lightolier Lytespan 8113 User manual

Lightolier Lytespan 6355 User manual

Lightolier

Lightolier Lytespan 6355 User manual

Lightolier Prospec 26190 User manual

Lightolier

Lightolier Prospec 26190 User manual

Lightolier QVS2GSDOS2FT User manual

Lightolier

Lightolier QVS2GSDOS2FT User manual

Lightolier Paraplus II PPH2G12FW228 User manual

Lightolier

Lightolier Paraplus II PPH2G12FW228 User manual

Lightolier COVERS ALL MINI-BRACELET FIXTURE SERIES Guide

Lightolier

Lightolier COVERS ALL MINI-BRACELET FIXTURE SERIES Guide

Lightolier Lytecaster 1101FEL User manual

Lightolier

Lightolier Lytecaster 1101FEL User manual

Lightolier Lytecaster 1149 User manual

Lightolier

Lightolier Lytecaster 1149 User manual

Popular Light Fixture manuals by other brands

FOS Technologies TOURING L005528 manual

FOS Technologies

FOS Technologies TOURING L005528 manual

CO/Tech FIB75600v0 instruction manual

CO/Tech

CO/Tech FIB75600v0 instruction manual

Evo-lite Auragami AG1-24-RGBW Series instruction manual

Evo-lite

Evo-lite Auragami AG1-24-RGBW Series instruction manual

HAMPTON BAY 18020 Installation instruction

HAMPTON BAY

HAMPTON BAY 18020 Installation instruction

LIVARNO LUX 291994 Operation and safety notes

LIVARNO LUX

LIVARNO LUX 291994 Operation and safety notes

Evo-lite MOVING BEAM 5R user manual

Evo-lite

Evo-lite MOVING BEAM 5R user manual

HAMPTON BAY SKU 185-632 instruction manual

HAMPTON BAY

HAMPTON BAY SKU 185-632 instruction manual

Falconeyes LP-DB2245-SY/AB instruction manual

Falconeyes

Falconeyes LP-DB2245-SY/AB instruction manual

Vari Lite VLZ SPOT quick start guide

Vari Lite

Vari Lite VLZ SPOT quick start guide

HAMPTON BAY SKU 776-449 instruction manual

HAMPTON BAY

HAMPTON BAY SKU 776-449 instruction manual

Qlight S80L operating instructions

Qlight

Qlight S80L operating instructions

Vari Lite VL2000 user manual

Vari Lite

Vari Lite VL2000 user manual

SilverStar SPOT 150 user manual

SilverStar

SilverStar SPOT 150 user manual

Claypaky supersharpy instruction manual

Claypaky

Claypaky supersharpy instruction manual

HAMPTON BAY NXT-LV-2002 Use and care guide

HAMPTON BAY

HAMPTON BAY NXT-LV-2002 Use and care guide

Esseci ISIB LED IP54 Assembly instructions

Esseci

Esseci ISIB LED IP54 Assembly instructions

HQ Power VDLLPL 1 Series user manual

HQ Power

HQ Power VDLLPL 1 Series user manual

HAMPTON BAY 79132 Use and care guide

HAMPTON BAY

HAMPTON BAY 79132 Use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.