631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • D0211
Lytecaster Performance Recessed Downlighting 1101H
Page 2 of 2 6 ¾" Aperture Horizontal Open, Performance Series, Reflector Trim
Job Information Type:
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
0
181
363
544
725
60˚
30˚
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
** Efficiency = 61.7% **
0-30 516.68 23.5 38
0-40 827.14 37.6 60.9
0-60 1337.28 60.8 98.5
0-90 1357.97 61.7 100
90-120 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 1357.97 61.7 100
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 73 73 73 73 72 72 69 69 66 66 62
169 67 65 63 65 62 63 60 61 58 55
264 60 57 54 59 54 57 5 2 55 5 1 49
359 54 50 47 53 47 52 4 6 50 4 5 43
4 55 49 44 41 48 41 47 40 45 40 38
5 51 44 40 36 44 36 42 36 41 35 34
648 40 36 32 40 32 39 32 38 34 31
744 37 32 2 9 36 29 35 28 35 31 28
8 41 34 29 26 33 26 33 26 32 28 26
9 39 31 27 23 31 23 30 23 30 26 23
10 36 29 24 21 29 21 28 21 27 24 21
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
CANDLEPOWER SUMMARY
Angle 0˚ CP 90˚ CP
0 720 720
5 722 725
10 689 697
15 641 633
20 626 558
25 621 535
30 573 569
35 492 483
40 416 399
45 383 336
50 366 321
55 318 306
60 42 44
65 9 9
70 5 6
75 4 4
80 3 3
85 2 3
90 2 3
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 68.47
10-20 181.71
20-30 266.5
30-40 310.46
40-50 281.1
50-60 229.04
60-70 13.53
70-80 4.17
80-90 2.98
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
12
SC = 1.1 1 = 90˚
2 = 0˚
CERTIFIED TEST REPORT NO. 3166FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
100W ED-17 COATED METAL HALIDE, LUMEN RATING = 7900 LMS, CL FINISH TRIM
CERTIFIED TEST REPORT NO. 4056FR
60˚
30˚
Coefficients Of Utilization
Ceiling 80% 70% 50% 30% 0
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 66 66 66 66 64 64 62 62 59 5 9 55
1 62 60 58 56 59 56 56 54 54 52 50
257 54 51 48 53 48 51 47 49 46 44
353 48 45 42 48 41 46 41 45 40 38
4 49 44 39 36 43 36 42 36 40 35 34
5 46 39 35 32 39 32 38 31 37 31 30
642 36 31 28 35 28 34 28 33 28 26
739 33 28 25 32 25 31 25 31 25 24
837 30 26 23 29 22 29 22 28 22 21
9 34 27 23 20 27 20 26 20 26 20 19
10 32 25 21 19 25 18 25 18 24 18 17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Candlepower Distribution
045 90
01959 1959 1959
52033 1948 1955
10 2142 1913 1870
15 2120 1880 1842
20 2044 1835 1780
25 2160 1732 1713
30 1997 1687 1673
35 1826 1587 1577
40 1588 1403 1386
45 1432 1206 115 9
50 1203 1027 1005
55 1087 944 896
60 215 178 167
65 41 37 46
70 30 24 13
75 10 31 12
80 12 21 24
85 10 12 9
90 16 13 7
Trim/Frame: 1101HCLHID
Lamp lumens: 7900 lm
Input Watts: 119W
Efficiency: 56.00 %
Spacing Criterion (0-180): 1.42
Spacing Criterion (90-270): 1.28
Multiple Unit Data - RCR 2
Spacing Avg.Initial Watts/
On Ctr. Footcandles Sq. Ft.
6' 106 2.97
8' 74 2.06
10' 47 1.32
38'x38'x10' Room, Workplane 2 1/2'
above oor, 80/50/20% Reectances
Zonal Lumens And Percentages
Zone Lumens %Luminaire
0-30 1571 36.0%
0-40 2593 59.0%
0-60 4289 98.0%
0-90 4382 100.0%
0
500
1000
1500
2000
Single Unit Data 100W 1101HCLHID
Height to Initial Beam
Lighted Plane Footcandles Diameter
8' 30 11'
10' 20 14'
12' 14 17'
14' 10 20'