Prismalyte Plus PRA2GRFVA2FT or 3FT
Page 1 of 2 2' x 2' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 2 or 3 Lamp, Twin Tube T5
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group S ction 1A/Folio E20-34 R v. A
Lightolier is a Philips group brand
09/09
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
• 5" deep body.
• 2-9/16" lamp to lens for better lamp obscuration.
• 75.4% efficient (3 lamp TT5).
• Black housing exterior for cooler ballast operating temperature.
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner aluminum lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• 2 lamp TT5 available.
• Construction to meet NYC Code Requirements or Chicago Plenum is
available.
Mounting M thods Dim nsions
Gxpos d T-grid c iling. Txpos d slot T-grid c iling.
drywall kit. (S options)
1/4" max.
1-1/2" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
1-7/8" max.
9/16"
24"
23-7/8"
(606mm)
15-11/16"
(398mm)
3-1/2"
(89mm)
5"
(127mm)
C
L
Air supply slots
(PRA only)
2"x 2-1/2" access plate
with two K.O.s (7/8" dia.)
24" (610mm)
5" (127mm)
24" (610mm)
5" (127mm)
arthquak clip
install d
(lay-in grid)
arthquak clip
b for
installation
Order Catalog Number: FK92X2.
Prismalyte Plus PRA2GRFVA2FT or 3FT
Page 2 of 2 2' x 2' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 2 or 3 Lamp, Twin Tube T5
Ord ring Information
Explanation of Catalog Number. Example: PRA2GRFVA3FTUNVI3
Options/Acc ssori s
Sp cial L ns s: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
Radio Int rf r nc Filt r:
To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
SUFFIX: B..
Air Closur Strip: SUFFIX ACS2 (factory installed).
El ctrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2.
(Request Folio OA30-10 Rev. A).
Chicago Pl num: SUFFIX: C.
Sp cifications
P rformanc : In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To prevent
glare the VCP shall be not less than 36 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 4656 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.2%.
Air Handling: (PRA only) side air passages for air supply or air return. Supply air is dis-
charged vertically. Optional side closure strips. Air return is also provided through the lamp
compartment through fixture body ends.
Sp cifications (continu d)
Mat rials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed over and hous-
ing ends turned-in for safe handling.
Finish:Chassis xt rior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86%
reflectance. Phosphate undercoating.
L ns s:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge,
.095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
El ctrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use
wire suitable for at least 90°.
Lab ls: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Photom try Mod l No. PRA2GRFVA3FT120X3 LER = FP - 42.7 IW - 76.0 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = 5.62
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
2
Fixtur
Width
C iling Typ :
G= Grid
(lay-in T bar)
T= Slot grid or
two-directional
concealed T
see options)
RF
L ns Shi lding
Typ :
VA=Virgin acrylic
(standard), see
options and
consult factory
Lamp
Quantity
2=2 Lamp
3=3 Lamp
FT
Lamp Typ /
Fixtur L ngth:
Twin Tube T5
(Nominal 24")
Not : For Linear
T5 Lamp option,
consult factory
Options:
Add appropriate suffix to
catalog no., ie: (C)
Ballast Typ :
<20THD <10THD
1 & 2 Lamp Elec. TT5 SB * IB *
(40 Watt)
1-3 Lamp Elec. TT5 X3 * I3 *
(40 Watt)
LOL TT5 Dimming PB –
(40 Watt)
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For TT5 UNV, you must use
I
B,
I
3
Ballast Code.
co ffici nts of utilization — zonal cavity m thod (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 83 80 77 75 73 71 72 70 69
2 76 71 66 67 63 60 64 61 59
3 70 63 58 60 55 52 58 54 51
4 65 57 51 54 49 45 52 48 44
5 60 51 45 49 44 40 47 43 39
6 56 46 40 44 39 35 43 38 35
7 52 42 36 41 35 31 39 35 31
8 48 39 33 37 32 28 36 32 28
9 45 36 30 34 29 26 34 29 26
10 43 33 27 32 27 23 31 27 23
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 44 47 53 60 42 46 51 58
20 30 37 40 44 49 34 38 42 47
20 40 34 36 40 43 31 33 37 41
20 60 31 33 35 39 28 30 32 36
30 20 45 49 53 58 44 48 51 57
30 30 38 41 44 48 35 39 42 46
30 40 34 36 39 42 31 34 37 40
30 60 31 33 34 37 28 30 31 35
30 80 31 32 32 34 27 29 29 32
40 20 47 51 54 58 46 50 53 58
40 30 39 42 45 49 37 41 44 47
40 40 35 37 40 42 32 35 38 40
40 60 32 34 34 37 29 31 32 35
40 80 31 32 32 34 28 29 29 32
40 100 32 32 31 32 29 29 28 30
60 30 40 44 46 50 39 43 45 49
60 40 36 38 40 43 34 36 38 42
60 60 33 34 34 37 30 32 32 35
60 80 32 32 32 34 29 30 29 32
60 100 32 32 30 32 29 29 28 30
100 40 39 41 42 45 38 40 41 45
100 60 36 37 36 39 34 35 35 38
100 80 35 35 33 35 32 32 31 34
100 100 35 34 32 33 32 31 29 30
room cavity ratio
luminaries lengthwise
luminaries crosswise
Voltag :
120, 277 or
UNV=120-277
Body Styl :
A=Air
Handling
S=Static
PR Standard Prismalyte Plus
PK For NYC Code – I.B.E.W. Manufactured
PX For NYC Code – Local 3 Manufactured
Prismalyt Plus:
Floating Lens Frame
Recessed Fluorescent
Troffer
L ns Fram :
RF=1/2" regressed
floating aluminum
frame with 7/16"
black reveal four
sides.
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group S ction 1A/Folio E20-34 R v. A
Job Information Type:
Lightolier is a Philips group brand

This manual suits for next models

1

Other Lightolier Lighting Equipment manuals

Lightolier Lighting Systems F7000-16 User manual

Lightolier

Lightolier Lighting Systems F7000-16 User manual

Lightolier SUS SERIES 432 User manual

Lightolier

Lightolier SUS SERIES 432 User manual

Lightolier ProSpec 37110 User manual

Lightolier

Lightolier ProSpec 37110 User manual

Lightolier UCS User manual

Lightolier

Lightolier UCS User manual

Lightolier Lytespan 23F70T6 User manual

Lightolier

Lightolier Lytespan 23F70T6 User manual

Lightolier ProSpec 37122 User manual

Lightolier

Lightolier ProSpec 37122 User manual

Lightolier Lytespan 83W6 User manual

Lightolier

Lightolier Lytespan 83W6 User manual

Lightolier HDB2SLW154 User manual

Lightolier

Lightolier HDB2SLW154 User manual

Lightolier ProSpec DRP11 User manual

Lightolier

Lightolier ProSpec DRP11 User manual

Lightolier Brisa FP14U_3d User manual

Lightolier

Lightolier Brisa FP14U_3d User manual

Lightolier FRS2GFW26U User manual

Lightolier

Lightolier FRS2GFW26U User manual

Lightolier Lytespan 22SR6 User manual

Lightolier

Lightolier Lytespan 22SR6 User manual

Lightolier Lighting Systems Baselyte-BSL15 User manual

Lightolier

Lightolier Lighting Systems Baselyte-BSL15 User manual

Lightolier TCU Series User manual

Lightolier

Lightolier TCU Series User manual

Lightolier FBP Low Profile Fluorescent Emergency Ballast... User manual

Lightolier

Lightolier FBP Low Profile Fluorescent Emergency Ballast... User manual

Lightolier 9033 User manual

Lightolier

Lightolier 9033 User manual

Lightolier PLA2G9LP32U User manual

Lightolier

Lightolier PLA2G9LP32U User manual

Lightolier LYTEDROP FIXTURE Guide

Lightolier

Lightolier LYTEDROP FIXTURE Guide

Lightolier Baselyte-BSL8 User manual

Lightolier

Lightolier Baselyte-BSL8 User manual

Lightolier Lytespan DR2C User manual

Lightolier

Lightolier Lytespan DR2C User manual

Lightolier Lytecaster 406X User manual

Lightolier

Lightolier Lytecaster 406X User manual

Lightolier Baselyte-BSL29 User manual

Lightolier

Lightolier Baselyte-BSL29 User manual

Lightolier LSB-6 User manual

Lightolier

Lightolier LSB-6 User manual

Lightolier Calculite A-E User manual

Lightolier

Lightolier Calculite A-E User manual

Popular Lighting Equipment manuals by other brands

SGM PALCO 3 user manual

SGM

SGM PALCO 3 user manual

Adam Hall 87451SMART manual

Adam Hall

Adam Hall 87451SMART manual

AEG A18SL Original instructions

AEG

AEG A18SL Original instructions

Yongnuo YNLUX100 PRO user manual

Yongnuo

Yongnuo YNLUX100 PRO user manual

Durite 0-441-05 quick guide

Durite

Durite 0-441-05 quick guide

OPTOCEUTICS EVY LIGHT user manual

OPTOCEUTICS

OPTOCEUTICS EVY LIGHT user manual

Springtree HD202 WW user manual

Springtree

Springtree HD202 WW user manual

Quintezz LED 10W FLOODLIGHT user manual

Quintezz

Quintezz LED 10W FLOODLIGHT user manual

Varytec GLC-1 quick start guide

Varytec

Varytec GLC-1 quick start guide

Sealey LED042 instructions

Sealey

Sealey LED042 instructions

Premise HB4 Series installation instructions

Premise

Premise HB4 Series installation instructions

Würth WGL 2 Translation of the original operating instructions

Würth

Würth WGL 2 Translation of the original operating instructions

American DJ Electra 250 User instruction

American DJ

American DJ Electra 250 User instruction

Castaldi Lighting D51/0 thor Installation and maintenance sheet

Castaldi Lighting

Castaldi Lighting D51/0 thor Installation and maintenance sheet

EuroLite LED H2O RGB 10W DMX Spot user manual

EuroLite

EuroLite LED H2O RGB 10W DMX Spot user manual

Halo HLBPH-4 Series instructions

Halo

Halo HLBPH-4 Series instructions

CircuPool RJ-Classic Series Installation and operation guide

CircuPool

CircuPool RJ-Classic Series Installation and operation guide

Grizzly T33679 instructions

Grizzly

Grizzly T33679 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.