FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER’S MANUALS
Copyright © LINAK 2019.04 . MA-M9-02-590-A .LINAK A/S reserves the right to make technical alterations
I/O Specifications
9
2019 © LINAK A/S
Endstop signals and relative positioning - Single hall
Input/Output Specification Comments
Description The actuator can be equipped with Single hall that
gives a relative positioning feedback signal when the
actuator moves.
See connection diagram, figure above
Brown 12-24VDC (+/-)
12V ± 20%
24V ± 10%
Under normal conditions:
12V, max. 5A depending on load
24V, max. 2.5A depending on load
To extend actuator:
Connect Brown to positive
To retract actuator:
Connect Brown to negative
Blue To extend actuator:
Connect Blue to negative
To retract actuator:
Connect Blue to positive
Red Signal power supply (+) 12-24VDC Current consumption:
Max. 40mA, also when the
actuator is not running
Black Signal power supply GND (-)
Green Endstop signal out Output voltage min. VIN - 2V
Source current max. 100mA
NOT potential free
Yellow Endstop signal in
Violet Single Hall output (PNP)
Movement per single Hall pulse:
LA25030 Actuator = 0.25 mm per pulse
LA25060 Actuator = 0.5 mm per pulse
LA25090 Actuator = 0.75 mm per pulse
LA25120 Actuator = 1.0 mm per pulse
LA25200 Actuator = 1.7 mm per pulse
Depending on load the frequecy is 10-20 Hz
Pulse ON time is minimum 8ms. OFF time between two
ON pulses is minimum 8ms.
Overvoltage on the motor can result in shorter pulses.
Output voltage min. VIN - 2V
Max. current output: 12mA
Max. 680nF
N.B. For more precise
measurements, please contact
LINAK A/S.
Low frequency with a high load.
Higher frequency with no load.
Input: Single hall output:
White Not to be connected