Lindy 39430 User manual

Page 4
Remote Console
Starting the Remote Console opens an additional window. It displays the screen content of your
host system. The Remote Console will behave in exactly the same way as if you were sitting
directly in front of the screen of your host system. However, be aware of the fact that the host
system will react to keyboard and mouse actions with a slight delay.
The upper part of the Remote Console window contains a control bar. Using its elements you
can see the state of the Remote Console and influence the local Remote Console settings.
There are several options to choose from, below is an introduction to the most important ones.
Please refer to the User Manual for further options and information.
Auto Adjust button
If the video display is poor quality or distorted in some way, click this button and wait a few
seconds while the KVM IP ACCESS MODULE adjusts itself for the best possible video quality.
Sync mouse
Choose this option in order to synchronize the local AND remote mouse cursors. If the mouse
does not synchronize, select Intelligent Sync from the Mouse Handling sub menu of the
Remote Console Option menu.
Video Settings (from within the Options Menu)
This opens a new window from which you can adjust brightness, contrast etc. of the displayed
picture in the Remote Console window.
Quick Installation is now complete. Refer to the full User Manual on the supplied CD for
more information about the advanced features of the KVM over IP Access Module!
KVM IP Access Module Quick Start Guide
Tested to comply with FCC Standarads. For commercial use only.
Page 1
RJ45 Ethernet
connection
RS232 serial
port connection
USB port
connection
Backplane connection to
U-Series KVM switch
Package Contents
Introduction:
The IP access module provides remote KVM over IP access to the KVM switch U8/16. It
converts all keyboard video and mouse signals and sends them as TCP/IP signals over your
LAN/WAN connection. The KVM switch U8/16 may be accessed from any computer connected
to your network and provides full KVM access including BIOS level access to all the connected
computers. The KVM over IP Access module can be accessed via a web browser and via
dedicated software tools included with the product. It uses secured encrypted sessions and
password authentification.
Please note that KVM over IP does not operate in a “real time” environment and that some
degree of time delay will occur due to limiting factors such as available bandwidth and network
traffic.
Installation:
Before you install the IP Access module into the KVM switch ensure all connected computers
are switched off and the power supply is unplugged. Proceed to unscrew and remove the small
metal cover on rear of the KVM switch. Carefully slide the module into the slot and secure in
place with the screw previously removed. The spare product label with MAC address and serial
number may be affixed to the KVM Switch for future reference. You may now proceed to power
up all connected equipment and connect the IP module and check for correct operation.
Connections
IP ACCESS Module
RS232 Serial cable, 1.8m
USB A to Mini-B Cable, 1m
Software & User Manual CD
This Quick Start Guide
This Quick Start Guide provides a brief introduction to the KVM over IP ACCESS
module for the LINDY U-Series KVM switches and shows you how to quickly set up t
he
device for use. For more detailed operation instructions please consult the full User
Manual on the supplied CD.
Page 2
1. (Optional) If you want to use the remote mass storage control feature, use the supplied
USB A to Mini-B cable to connect the USB port on the KVM IP ACCESS Module to a
USB port on the host system
2. (Optional) Connect a modem or RS232 terminal or RS232 to the RS232 serial port
connection
3. Connect an Ethernet cable to the RJ-45 Ethernet port.
Configuration
By default, the KVM IP ACCESS MODULE will try to contact a DHCP server in the subnet to
which it is physically connected. If a DHCP server is found, it will provide a valid IP address,
gateway address and net mask. Before you connect the device to your local subnet, be sure to
complete the corresponding configuration of your DHCP server. It is recommended to configure
a fixed IP assignment to the MAC address of the KVM IP ACCESS MODULE. You can find the
MAC address details on the printed label on the underside of the IP Access module.
KVM IP ACCESS MODULE Setup Tool
Start the setup tool from the CD ROM -
On the upper left corner, the MAC address of the KVM IP ACCESS MODULE is displayed. To
detect the MAC address, press the Refresh Devices button. The displayed MAC address
should correspond to the printed address shown on the label on the base of the IP module.
On the lower right corner of the window, there are two buttons: Query Device and Setup
Device. Press the Query Device button to display the preconfigured values of the network
configuration. The values are displayed in the text fields located above. If necessary, adjust the
network settings to your needs. To save the changes enter a user login and a password (the
default user name is super, the default password is pass) and then press the Setup Device
button.
Page 3
Logging In
The KVM IP ACCESS MODULE can be entirely managed using a standard web browser. You
can access the KVM IP ACCESS MODULE using the insecure HTTP protocol, or using the
encrypted HTTPS protocol. Whenever possible, use HTTPS.
In order to use the Remote Console window of your managed host system, the browser must
feature Java Runtime Environment version 1.1 or higher support. If the browser has no Java
support (such as on a small handheld device), you can still maintain your remote host system
using the administration forms displayed by the browser itself.
Launch your web browser. Direct it to the address of your KVM IP ACCESS MODULE.
Example: Type the following in the address line of your browser when establishing an
unsecured connection:
http://<IP address of KVM IP ACCESS MODULE>
When using a secure connection, type in:
https://<IP address of KVM IP ACCESS MODULE>
This will lead you to the KVM IP ACCESS MODULE login page as shown below:
The KVM IP ACCESS MODULE has a built-in super user account that has all the permissions
enabled to administrate your KVM IP ACCESS MODULE switch:
Login name super (factory default)
Password pass (factory default)
Once logged into the KVM IP ACCESS MODULE successfully, the main page appears.
To launch the Remote Console click on the Console icon –
Important: For optimum operation, w
e recommend you install the latest
version of Sun’s Java Virtual Machine 1.5
which can be downloaded from
the following web site:
www.java.com

Other Lindy Control Unit manuals

Lindy EDID 32100 User manual

Lindy

Lindy EDID 32100 User manual

Lindy 32655 User manual

Lindy

Lindy 32655 User manual

Lindy 21981 User manual

Lindy

Lindy 21981 User manual

Lindy EIDE UDMA/100 User manual

Lindy

Lindy EIDE UDMA/100 User manual

Lindy 25037 User manual

Lindy

Lindy 25037 User manual

Popular Control Unit manuals by other brands

Nice ROBO PLUS Installation instructions manual

Nice

Nice ROBO PLUS Installation instructions manual

JP Fluid Control ST-IB Series quick start guide

JP Fluid Control

JP Fluid Control ST-IB Series quick start guide

HEROSE 01312 operating instructions

HEROSE

HEROSE 01312 operating instructions

VAT 650 Series Installation, operating,  & maintenance instructions

VAT

VAT 650 Series Installation, operating, & maintenance instructions

Cornelius UF-1 Portion Control Operation and Programming Instructions

Cornelius

Cornelius UF-1 Portion Control Operation and Programming Instructions

Azbil HLS Series user manual

Azbil

Azbil HLS Series user manual

Genebre 2448 Installation, operation & maintenance manual

Genebre

Genebre 2448 Installation, operation & maintenance manual

Hara Systems OSTSen-9250 user guide

Hara Systems

Hara Systems OSTSen-9250 user guide

ICP DAS USA tM Series user manual

ICP DAS USA

ICP DAS USA tM Series user manual

Pulsar MSEP412 quick start guide

Pulsar

Pulsar MSEP412 quick start guide

On Automation EC2 instruction manual

On Automation

On Automation EC2 instruction manual

Thrane&Thrane SAILOR 630 Series installation guide

Thrane&Thrane

Thrane&Thrane SAILOR 630 Series installation guide

DataComm 70-0023 Instruction/installation sheet

DataComm

DataComm 70-0023 Instruction/installation sheet

Festo VZXA-K Instructions, operation

Festo

Festo VZXA-K Instructions, operation

Sony HKC-7081 Installation and maintenance manual

Sony

Sony HKC-7081 Installation and maintenance manual

Firmtech FBL770BC quick guide

Firmtech

Firmtech FBL770BC quick guide

ADTRAN Quad E1/PRA user manual

ADTRAN

ADTRAN Quad E1/PRA user manual

VPro MA Series instruction manual

VPro

VPro MA Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.