FEATURES
Alarm Condition of SPG
Audible Tone
Contact Closure
The PCA-819 Remote Changeover Alarm is an
add-onenhancementtothePCO-818changeover
system. The PCA-819 is engineered to provide a
convenient, and easy to use means of monitoring
changeover, due to loss of signal, at a remote
location.
Bi-color LED’s provide a visual indication of the
Changeover Frame status. Additionally, an
audible alarm sounds to indicate an alarm
condition. And to provide even more flexibility,
isolated relay contacts, both normally open, and
normally closed, are provided so the user can
control other equipment or alarms in the event of
a loss of signal at the Changeover Frame. Front
panel switches allow the user to disable the alarm
signal from either, or both, generator banks, and
also mute the audible alarm.
The PCA-819 is housed in a rugged 1RU rack-
mountenclosure,and canbepoweredfrom 120or
240VAC (internal jumper selectable).
Whenever a loss of signal occurs on any of the
various changeover modules in the PCO-818, an
alarmsignal isgenerated and thePCA-819 shows
the alarm condition on the front panel.
Disable Alarm
Connects to PCO-818
120 or 240 AC Operation
The PCA-819 has two Digital inputs, Gen A and
GenB. These signals are input onTB1 located on
therearpanel. Athree-wirecableconnectsTB1to
J3 on the rear of the PCO-818 frame. These
signals are active high, TTL level. Input A and/or
B can be disabled by their respective
enable/disable switch on the front panel. The
inputs are filtered for noise and clipped at 5.1V for
transient protection. Bi-color LED’s indicate an
RED alarm condition , GREEN condition OK, and
BLINKING GREEN unit has been disabled.
A circuit detects if either or both inputs, Gen A or
Gen B, has a failure, the speaker sounds off and
the relay is energized. The speaker is a self-
generating audible indicator and may be muted by
by front panel switches. The alarm output relay
provides both Normally Open and Normally
Closed contacts, capable of switching up to 5
amps at 120VAC or 30VDC. Varistors and a fuse
protectthecontactstherelayfrom transientspikes
and overloads.
The PCA-819 is powered from the AC line, with
theoptionofeither120V or240V, bychanging the
appropriate jumpers at JP1, JP2, and JP3.