manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Security Sensor
  8. •
  9. LST FTX-P1 User manual

LST FTX-P1 User manual

Other LST Security Sensor manuals

LST AD-58000-400 User manual

LST

LST AD-58000-400 User manual

LST Series 65/XP95 User manual

LST

LST Series 65/XP95 User manual

LST 4351E User manual

LST

LST 4351E User manual

LST OH-13001 User manual

LST

LST OH-13001 User manual

LST ECO1000BREL24L User manual

LST

LST ECO1000BREL24L User manual

LST 246100 User manual

LST

LST 246100 User manual

LST 2100RFT-AS User manual

LST

LST 2100RFT-AS User manual

LST Series FC600 User manual

LST

LST Series FC600 User manual

LST FI750/RF/O Operator's manual

LST

LST FI750/RF/O Operator's manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST IR2 16581 User manual

LST

LST IR2 16581 User manual

LST Series 200 User manual

LST

LST Series 200 User manual

LST AMS-58000-700 User manual

LST

LST AMS-58000-700 User manual

LST 16589 User manual

LST

LST 16589 User manual

LST AW-55000-420 User manual

LST

LST AW-55000-420 User manual

LST 5351TE User manual

LST

LST 5351TE User manual

LST ECO1000 User manual

LST

LST ECO1000 User manual

LST B312NL User manual

LST

LST B312NL User manual

LST 2251CTLE User manual

LST

LST 2251CTLE User manual

LST 5251EM User manual

LST

LST 5251EM User manual

LST Orbis RB-10004 User manual

LST

LST Orbis RB-10004 User manual

LST Orbis 246042 User manual

LST

LST Orbis 246042 User manual

LST ASR-45681-242 User manual

LST

LST ASR-45681-242 User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
FTX-P1_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Optical Filtrex Detector
FTX-P1
Description
The addressable Optical Filtrex Smoke Detector FTX-P1
uses the scattered light principle and was developed
for the detection of smoke particles in heavily conta-
minated areas. The detector is used, for example, in
industrial plants where dust is released by production
or cleaning.
By means of an integrated fan, air samples are drawn
into the sensing chamber through two separate fi lters.
The fan is powered by a separate 24VDC supply and
operates in a 15% duty cycle (5 seconds on, 30 se-
conds off), thus allowing low power consumption as
well as precise evaluation of the air samples.
The fi lters are monitored for contamination. They are
designed to let smoke reach the sensing chamber,
whereas causes of deceptive alarms (dust particles
and tiny drops of water) are kept away from it. The ou-
ter fi lter is removeable and can be cleaned or replaced
by the operator. The modern design of the sensing
chamber allows to reliably evaluate the characteristics
of fi re.
The proven ADM loop technology with System Sen-
sor/200 protocol establishes a permanent communi-
cation between the fi re detection control panel and the
detector. That ensures a periodical function testing of
the detector. In the control panel all types of fi res are
detected by continuously comparing fi re patterns.
Intelligent evaluation algorithms use the current condi-
tion of the sensing chamber to predict the likely time
of the next maintenance. Thus the alarm threshold is
automatically adjusted within the permissible range,
depending on the contamination. With that, the con-
stant response sensitivity of the detector is ensured
for the duration of its usage.
The two LEDs with 360° visibility indicate the activated
condition of the detector. The detector address is se-
lected with two decadic rotary switches, thus allowing
to change the detector without additional tools.
A detector function test can be conveniently conducted
using a magnet or test gas. The detector is attached to
the base B524FTXE.
• ADM loop technology with
System Sensor/200 protocol
• For use in heavily contaminated
areas
• Replaceable fi lter
• Constant response sensitivity
• Function testable with magnet
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
FTX-P1_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Operating voltage Supply through loop voltage
Current consumption sensor max. 230µA (quiescent)
Operating voltage fan 15 – 30VDC
Cyclic current consumption fan 6mA in quiescent state (30s),
60mA in operation (5s)
Ambient temperature -10°C to +55°C
Relative humidity 10 – 93% (no condensation)
Dimensions ø × H 102 × 89 (mm)
Colour cream
Weight 207g
Approval DIFT 0845-CPD-232.1427 (Denmark)
Order number 241019
Order name Optical Filtrex Smoke Detector/Anal./500/SS FTX-P1
Detector Base/Filtrex
Dimensions ø × H 102 × 35 (mm)
Colour cream
Weight 91g
Order number 246012
Order name Detector Base Filtrex/Anal./500/SS B524FTXE
Replacement Filter/Filtrex
Dimensions ø × H 80 × 19 (mm)
Colour cream
Weight 10g
Order number 249047
Order name Replacement Filter for Filtrex RF-FTX