manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LST
  6. •
  7. Smoke Alarm
  8. •
  9. LST MCP5A Series User manual

LST MCP5A Series User manual

Other LST Smoke Alarm manuals

LST GO-55000-317 User manual

LST

LST GO-55000-317 User manual

LST HT-11003 User manual

LST

LST HT-11003 User manual

LST FC600/TDIFF/57 User manual

LST

LST FC600/TDIFF/57 User manual

LST GM-55000-137 User manual

LST

LST GM-55000-137 User manual

LST 2251EIS User manual

LST

LST 2251EIS User manual

LST ECO1005T User manual

LST

LST ECO1005T User manual

LST AI-58000-500 User manual

LST

LST AI-58000-500 User manual

LST FC600/TMAX/78 User manual

LST

LST FC600/TMAX/78 User manual

LST 1151EIS User manual

LST

LST 1151EIS User manual

LST ECO1002 User manual

LST

LST ECO1002 User manual

LST GD-55000-132 User manual

LST

LST GD-55000-132 User manual

LST AO-55000-620 User manual

LST

LST AO-55000-620 User manual

LST BEAMLRK User manual

LST

LST BEAMLRK User manual

LST HT-11004 User manual

LST

LST HT-11004 User manual

LST FI750/RF/O User manual

LST

LST FI750/RF/O User manual

LST HT-11005 User manual

LST

LST HT-11005 User manual

LST OP-12001 User manual

LST

LST OP-12001 User manual

LST SLR-E-IS User manual

LST

LST SLR-E-IS User manual

LST ND2251EM User manual

LST

LST ND2251EM User manual

LST AO-58000-600 User manual

LST

LST AO-58000-600 User manual

LST ECO1004T User manual

LST

LST ECO1004T User manual

LST HT-11001 User manual

LST

LST HT-11001 User manual

LST GI-55000-217 User manual

LST

LST GI-55000-217 User manual

LST ÜMS-55000-841 User manual

LST

LST ÜMS-55000-841 User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
MCP5A_DBL_LST_EN_0804.PDF • PAGE 1
ABuilding Safety. Building Security.
Manual Call Point
Series MCP5A
Specifi cations
Description
The Manual Call Points Series MCP5A are certifi ed to
the standard EN 54-11/A and are designed for use in
ADM loops with System Sensor/200 protocol.
Two mechanical versions of the detector are available:
• With pane of glass: The detector is activated by
pressing in the pane of glass, which breaks into
two pieces at a predetermined breaking point. By
means of a special key, the detector case can be
opened and the pane of glass can be replaced.
• With pane of plastic: The detector is activated by
pressing in the pane of plastic without breaking it.
By means of a special key, the pane can be put
back to the idle position, thereby resetting the de-
tector.
Each of these two mechanical versions is available with
or without dual-isolator. The integrated dual-isolator dis-
connects the adjacent loop elements fast and safely in
case of a short circuit.
The activated condition of the manual call point is opti-
cally indicated by an LED. The detector address is se-
lected with two decadic rotary switches.
The detector is fi tted into a plastic case and can be
mounted on a 60mm fl ush-mount installation box. An
optional case for surface mounting on a wall can be
supplied.
• ADM loop technology with
System Sensor/200 protocol
• Available with pane of glass or plastic
• LED indicates activation
• Versions with or without dual-isolator
• Operating instructions by means of
standardised symbols
Operating voltage Supply through loop voltage
Ambient temperature -10°C to +55°C (no condensation or icing)
Relative humidity max. 95% (no condensation)
Protection class IP24
Dimensions W × H × D 89 × 93 × 28 (mm)
Colour fl ame red, RAL 3000
Weight 110g
Approval LPCB 166b/45, 166b/46
Manual call point with pane of glass, without isolator MCP5A-RP07FG
Current consumption 260µA (quiescent)
Order number 245040
Order name Manual Call Point/Red/200/Glass MCP5A-RP07FG
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
MCP5A_DBL_LST_EN_0804.PDF • PAGE 2
ABuilding Safety. Building Security.
Manual call point with pane of glass, with isolator MCP5A-RP08FG
Current consumption 360µA (quiescent)
Order number 245041
Order name Manual Call Point/Red/200/ISM/Glass MCP5A-RP08FG
Manual call point with pane of plastic, without isolator MCP5A-RP07FF
Current consumption 260µA (quiescent)
Order number 245042
Order name Manual Call Point/Red/200/Flexi MCP5A-RP07FF
Manual call point with pane of plastic, with isolator MCP5A-RP08FF
Current consumption 360µA (quiescent
Order number 245043
Order name Manual Call Point/Red/200/ISM/Flexi MCP5A-RP08FF
Accessories and replacement panes
Specifi cations
Surface Mount Box SR
Protection class IP24
Dimensions W × H × D 87 × 87 × 32 (mm)
Colour fl ame red, RAL 3000
Weight 52g
Order number 245019
Order name Surface Mount Box/MCP5A SR
Surface Mount Box SR3T
Protection class IP24
Dimensions W × H × D 87 × 87 × 32 (mm)
Colour fl ame red, RAL 3000
Weight 60g
Order number 245012
Order name Surface Mount Box/MCP5A SR3T
Replacement panes 10 pieces
Order number 249213
Order name Glass for MCP Series/10pcs. G21140
The Surface Mount Boxes SR and SR3T allow the sur-
face mounting of the Manual Call Points Series MCP5A.
The Surface Mount Box SR3T is provided with 3 auxilia-
ry terminals for easy wiring.
The printed replacement panes of glass are needed for
resetting an activated Manual Call Point MCP5A-RP07FG
or MCP5A-RP08FG. One package contains 10 pieces.