(3) Reservoir Type
Please make sure to refill the grease when the follow plate gets down to the low level.
When refilling, please make sure to refill through the refill port. Otherwise, it might cause a trouble.
Please pay attention not to introduce air and/or foreign particles into the reservoir.
3.5
Working Conditions(Please use within the range below.)
Working ambient temperature 0 deg. C - +40 deg. C
Working ambient humidity 35% - 85% (RH)
3.6
Air Bleeding
Please make sure to bleed air after connection of tubing and/or
air is introduced into the pump. Loosen the Air Bleeding Plug and
run the pump until no air comes out of the pump. When air
stop coming out, tighten theAir Bleeding Plug.
3.7
Timer on the Machine
This pump can be controlled (Discharge Time and Interval)by
the timer on a machine. Make sure to set ON and OFF time.
ON time should be less than 7min. 30sec. and OFF time should
be at least three (3) times longer than ON time. If this condition is not met,
it would activate solenoid valve thermostat and pump pressure does not rise.
When filling the main tubing with grease or commissioning, make sure to follow the
condition below.
ON time 30sec. and OFF time 90sec. Repeat this, but in total 30min. (Max.)
After 30min. operation in total, take one (1) hour interval.
Open
Close