Lucent Technologies H569-445 User manual

Secondary DC Power
Distribution Bay
H569-445
Product Manual
Select Code 157-005-104
Comcode 108405283
Issue 5
May 2000
© 2000 Lucent Technologies


Product Manual
Select Code 157-005-104
Comcode 108405283
Issue 5
May 2000
Lucent Technologies
Secondary DC Power Distribution Bay
H569-455
Notice:
The information, specifications, and procedures in this manual
are subject to change without notice. Lucent Technologies
assumes no responsibility for any errors that may appear in this
document.
© 2000 Lucent Technologies
All Rights Reserved
Printed in U.S.A.


Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Table of Contents - 1
Table of Contents
1 Introduction
Product Summary 1 - 1
Documentation 1 - 3
Customer Assistance Contacts 1 - 3
Customer Training 1 - 3
Customer Service 1 - 3
Technical Support 1 - 3
Product Repair and Return 1 - 4
Warranty Service 1 - 4
On-Line Power Systems Product Manuals 1 - 4
2 Product Description
Cabinet Arrangements 2 - 1
Features 2 - 2
Specifications 2 - 2
Cabinet Types and Features 2 - 3
Load Bus Arrangements 2 - 8
Discharge Return Bus Options 2 - 10
Lugs and Hardware 2 - 13
Breakers and Fuses 2 - 13
External Return Bus Bars 2 - 14
Digital Meters and Monitoring Shunts 2 - 15
G-70 2 - 15
G-71 2 - 16
ED83127-30 Fuse Panels 2 - 17
Groups 30A-30D 2 - 17
Groups 31A and 31B 2 - 19
Alarm Circuit Module (BEP1) 2 - 20
Detailed Circuit Description 2 - 23
Monitoring Multiple Alarm Modules for Negative Plants 2 - 25
Monitoring Multiple Alarm Modules for Positive Plants 2 - 27
Reference Data 2 - 28
3 Safety
Safety Statements 3 - 1
Warning Statements and Safety Symbols 3 - 3
Precautions 3 - 5

Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 List of Figures - 1
List of Figures
Figure 1-1: H569-445 Secondary DC Power
Distribution Bay 1 - 2
Figure 2-1: 2-1/2-Foot Extension Cabinet 2 - 4
Figure 2-2: 2-Foot or 4-1/2-Foot Extension Cabinet 2 - 5
Figure 2-3: Fuse Panel Position Numbering 2 - 6
Figure 2-4: Circuit Breaker Panel Position Numbering 2 - 7
Figure 2-5: Group 20 Load Connection Points 2 - 9
Figure 2-6: External Discharge Return Bus Options
on Cable Rack 2 - 11
Figure 2-7: Bus Bar Hole Pattern and Numbering
Schemes 2 - 12
Figure 2-8: G-70 Digital Meter 2 - 15
Figure 2-9: G-71 Digital Meter 2 - 16
Figure 2-10: H569-445 Group 30A-30D Fuse Panel
(One Shown; Two Are Provided Per Group) 2 - 18
Figure 2-11: H569-445 Groups 31A and 31B
Circuit Breaker Panel 2 - 19
Figure 2-12: A-CP/BEP1 Board Layout 2 - 21
Figure 2-13: A-CP/BEP1 Input/Output Connections
(Alarm Module With No Power Is in “Normal” State) 2 - 22
Figure 2-14: Frame Alarm 2 - 24
Figure 2-15: P102 Factory Alarm Wiring 2 - 25
Figure 2-16: P101 Frame Power Loss Alarm Wiring 2 - 26
Figure 2-17: Fuse or Circuit Breaker Alarm Wiring
for Positive Plant P101 2 - 27



Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Introduction 1 - 1
1 Introduction
Product
Summary This product manual (Select Code 157-005-104) describes the
H569-445 Secondary DC Power Distribution Bay. This unit is also
known as a Battery Distribution Fuse Bay (BDFB) or a Battery
Distribution Circuit Breaker Bay (BDCCB). The H569-445 series bay
is shown in Figure 1-1. It serves as a secondary fuse or circuit breaker
distribution center for dc power delivered from a central office battery
plant to the using equipment. It provides space-efficient branch loading
for distributing +24, -48, or ±130 volt dc power, or combinations of
these voltages from different battery plants. (BDCBB versions of the
Distribution Bay do not offer the ±130 volt dc option.)
In many applications, telecommunication equipment requires power
redundancy from the battery plant. A BDFB or BDCBB provides this
redundancy through the use of multiple load buses. The H569-445 is a
cabinetized distribution system that supports these applications by
providing up to six distinct load buses for the 7-foot cabinet or up to
eight distinct load buses for the 9-foot cabinet.
Each load bus has a rated current carrying capacity of 600 amperes.
Each load bus may be configured to include one or multiple fuse or
circuit breaker panels. Each fuse panel provides 20 mounting positions
that may be equipped with either WP-92461 cartridge fuses that range
from 3 to 70 amperes and/or GMT fuse modules containing three fuses
ranging from 1/2 to 5 amperes. Fuse panels may also be equipped with
70-150 ampere TPL type fuse blocks. Each circuit breaker panel
provides 20 positions for circuit breakers ranging from 3 to 100
amperes.
Additional features include: digital meters; remote monitoring
capability for alarms; multiple cabinet heights, and optional 2-hole
ground bus arrangements mounted either in the cabinet or external to
the cabinet on a cable rack. These options and many more provide
greater flexibility for customers with different distribution
requirements.

Lucent Technologies Secondary DC Power Distribution Bay H569-445
1 - 2 Introduction Issue 5 May 2000
Figure 1-1: H569-445 Secondary DC Power
Distribution Bay

Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Introduction 1 - 3
Documentation This product manual (Select Code 157-005-104) is part of a set of
documentation developed to assist engineering and installation
personnel. Additional product information includes the following:
• H569-445 Ordering and Installation Guide
• T-83150-30 Wiring Drawing
• SD-83150-01 Schematic Drawing
This documentation is provided with each H569-445 bay in
Documentation Service Kit, Comcode 848296505.
Customer
Assistance
Contacts
Customer Training Lucent Technologies offers customer training on many Power Systems
products. For information call 1-972-284-2163. This number is
answered from 8:00 a.m. until 4:30 p.m., Central Time Zone (Zone 6),
Monday through Friday.
Customer Service For customers in the United States, Canada, Puerto Rico, and the US
Virgin Islands, call 1-800-THE-1PWR (1-800-843-1797). Services
provided through this contact include initiating the spare parts
procurement process for out of service emergencies, ordering Lucent
Technologies documents, and providing other product and service
information.
For other customers worldwide, call 001-972-840-0382. This number
is answered from 8:00 a.m. until 4:30 p.m., Central Time Zone (Zone
6), Monday through Friday.
Technical Support Technical support for Lucent Technologies customers is available
around the world during the normal product warranty period and also
while specific contractual agreements extend this service.
For customers in the United States, Canada, Puerto Rico, and the US
Virgin Islands, call 1-800-CAL-RTAC (1-800-225-7822) to contact a
product specialist to answer your technical questions and assist in
troubleshooting problems.
For other customers worldwide, contact your local field support center
or your sales representative to discuss your specific needs.

Lucent Technologies Secondary DC Power Distribution Bay H569-445
1 - 4 Introduction Issue 5 May 2000
Customer Assistance Contacts, continued
Product Repair and
Return Repair and return service is provided for Lucent Technologies
customers around the world.
For customers in the United States, Canada, Puerto Rico, and the US
Virgin Islands, call 1-800-255-1402 for information on returning of
products for repair.
For other customers worldwide, contact your sales representative to
discuss your particular circumstances.
Warranty Service For domestic warranty service, contact your Warranty Service Manager
(WSM). For international warranty service, contact your sales
representative.
On-Line Power
Systems Product
Manuals
For Lucent Technologies users logging in from inside the corporate
firewall, the address of the “Power Systems On-Line Product Manuals”
page is http://www.cic.lucent.com/lineage.html.
For customers logging in from outside the firewall, the address is
http://www.lucent8.com/lineage.html. The annual subscription fee for
access to this site is $25. To obtain a password, follow the instructions
on-line or call 1-888-Lucent8 (1-888-582-3688). When prompted for
an order number, enter or say “167-790-010.”

Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Product Description 2 - 1
2 Product Description
Cabinet
Arrangements The Secondary DC Power Distribution Bay, Model H569-445, is
available in five cabinet arrangements. These include:
7-foot cabinet: 26 inches wide by 15 inches deep
7-foot cabinet with 2-foot extension cabinet
7-foot cabinet with 4-1/2-foot extension cabinet
9-foot cabinet: 26 inches wide by 18 inches deep
9-foot cabinet with 2-1/2-foot extension cabinet
The7-footcabinet has sixfuseorcircuitbreaker panel positions and the
9-foot cabinet has eight fuse or circuit breaker panel positions. Alarms
include both remote signaling and visual indication of fuse or circuit
breaker failure and panel power loss.
The 7-foot cabinet may be configured with one to six separate load
buses. The 9-foot cabinet may be configured with one to eight separate
load buses.All input battery and battery return feeds are terminated at
the load connection pointon the fuse or circuit breaker panel. Each load
connection point has a 800A monitoring shunt. A digital meter is also
provided with each bay.
Load leads from each fuse or circuit breaker are routed along cable
troughs on either side of the cabinet. Discharge return leads from the
load equipment can be handled in one of two ways. A discharge return
bus bar arrangement mounted either on the fuse or circuit breaker
panels in the cabinet or external to the cabinet on a cable rack. Both
configurations comply with Bellcore 2-Hole grounding requirements.

Lucent Technologies Secondary DC Power Distribution Bay H569-445
2 - 2 Product Description Issue 5 May 2000
Features The following is a list of the many features provided with this product:
• Distributes +24, -48, or ±130 volt dc power (±130 volt not offered
with BDCBB)
• 7-, 9-, or 11-1/2-foot cabinet arrangements
• One to eight load buses
• Digital meter
• Cable entry from the top or bottom of cabinet
• 120 cartridge fuse or circuit breaker positions in 7-foot cabinet
• 160 cartridge fuse or circuit breaker positions in 9-foot cabinet
• Accommodates fuse sizes 1/2 to 150 amperes or circuit breaker
sizes 3 to 100 amperes.
• 800-ampere monitoring shunts
• Frame alarm indicator lamp
• Panel fuse or circuit breaker alarm and power loss indicator lamps
• Individual fuse or circuit breaker alarm indicator
• Alarm circuit modules for remote monitoring
• Optional internal or external ground bus arrangements
Specifications Group 1 Cabinet: Six fuse or circuit breaker panel positions
Height 84 inches (2134mm)
Width 26 inches (660mm)
Depth 15 inches (381mm)
Weight approx. 375 pounds (6 panels)
Group 2 Cabinet: Eight fuse or circuit breaker panel positions
Height 108 inches (2743mm)
Width 26 inches (660mm)
Depth 18 inches (457mm)
Weight approx. 450 pounds (8 panels)

Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Product Description 2 - 3
Cabinet Types
and Features Two cabinet types and three cabinet extension options are available:
Group 1 7 ft Cabinet
Group 2 9 ft Cabinet
848258562 2-1/2 ft Extension Cabinet for 9 ft cabinet
848258588 4-1/2 ft Extension Cabinet for 7 ft Cabinet
848258570 2 ft extension cabinet for 7 ft cabinet
The Group 1 cabinet contains six fuse or circuit breaker panel positions
and the Group 2cabinethaseight fuse or circuitbreaker positions.Each
of these panel positions must be equipped with either a fuse panel, a
circuit breaker panel, or a Group 90 blank panel.
The 848258562 2-1/2-foot extension cabinet mounts on top of the
9-foot cabinet as shown in Figure 2-1. Constructed in the same manner
as theother cabinets, itoffers aclean,aesthetically pleasing solutionfor
11-1/2-foot central office applications. Interconnection hardware and
interframe ground cabling and mounting hardware are furnished to
provide a continuous frame ground to the top of the cabinet.
The 848258588 4-1/2-foot extension cabinet for the Group 1 cabinet
offers another option for the 11-1/2-foot office environment. The
848258570 2-foot extension cabinet for the Group 1 cabinet to offers a
similar option for the 9-foot environment. The extensions, shown in
Figure 2-2, may be disassembled if future wire center modernization
requires a 7-foot office environment. Intercabinet ground cable and
mounting hardware is furnished to provide a continuous frame ground
to the top of the cabinet.
The frame ground connection is located on top of each cabinet.
Connection is made using a 1/4 inch double hole terminal lug on .625
inch centers. For ground wire connection greater than 2 gauge, order
Comcode 846337798 bus bar adapter to allow for 3/8 inch double hole
terminal lugs on 1.00 inch centers.
Cabinets may be configured for either top or bottom cable entry. For
either configuration, the dc cable designations may start with position
1 at the top left or bottom right. Figures 2-3 and 2-4 show the possible
configurations. When ordering fuse or circuit breaker panels for the
distribution bay it is important to remember the numbering schemes
associated with top and bottom feed applications. Refer to Figures 2-3
and 2-4 for fuse or circuit breaker panel position numbers for each
application. This information is necessary to communicate where fuse
or circuit breaker panels with different configurations shouldbe located
on factory orders. Panel numbering is also stamped on the front of each
cabinet at the factory as an installation reference.

Lucent Technologies Secondary DC Power Distribution Bay H569-445
2 - 4 Product Description Issue 5 May 2000
Cabinet Types and Features, continued
Figure 2-1: 2-1/2-Foot Extension Cabinet
9' Cabinet
Frame
Mounting
Hardware
Ground Strap

Lucent Technologies Secondary DC Power Distribution Bay H569-445
Issue 5 May 2000 Product Description 2 - 5
Cabinet Types and Features, continued
Figure 2-2: 2-Foot or 4-1/2-Foot Extension Cabinet
7' Cabinet7' Cabinet
Frame
Mounting
Hardware
Frame
Mounting
Hardware
Ground
Strap Ground
Strap
Lucent
Lucent
2'
4-1/2'

Lucent Technologies Secondary DC Power Distribution Bay H569-445
2 - 6 Product Description Issue 5 May 2000
Cabinet Types and Features, continued
Figure 2-3: Fuse Panel Position Numbering
Group 10A: Top Feed A
Group 10D: Bottom Feed B
or
Note: 7 foot cabinet shown.
Similar for 9 foot cabinet.
Panel Position 1
(fuse panel shown) Panel Position 2
(fuse panel shown)
Panel Position 3
(fuse panel shown)
Panel Position 5
(blank panel shown)
Panel Position 4
(fuse panel shown)
Panel Position 6
(blank panel shown)
Populated with DC panels from
the top down. Cables are
routed out of cabinet.bottom
Populated with DC panels from
the top down. Cables are
routed out of cabinet.top
Table of contents
Other Lucent Technologies Power Distribution Unit manuals