SETUP AND CONFIGURATION
1Physical Installation
The XMS-1010P can be rack-mounted or used as a desktop switch. Install the
XMS-1010P in a stable/safe place to avoid any possible damage. Make sure
there is adequate space around the XMS-1010P for ventilation and proper
heat dissipation; Luxul recommends at least 4-6 inches around all sides. Avoid
placement in direct sunlight. Do not place heavy articles on the XMS-1010P
and verify the ground connection of the outlet is functioning properly.
Desktop/Shelf Installation
For desktop/shelf installation, attach the four rubber feet to the corner inden-
tations on the bottom of the XMS-1010P, then place the switch horizontally
on a solid, level platform.
Rack Installation
Use the included L brackets for convenient installation in a 19-inch server or
audio rack. As shown below, use four screws to attach the L-shaped brackets
on either sides of the XMS-1010P, and horizontally insert the switch into the
rack. Use your desired hardware to affix the switch supports to the rack.
Attach feet for desktop installation Install brackets for rack-mounting
2Connecting Ethernet and Power
Ethernet and Power Connections
Use any RJ-45 to connect the XMS-1010P to an Ethernet-enabled device,
including servers, routers or other switches. No crossover cable is necessary.
The XMS-1010P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/
full-duplex mode and 1000 Mbps full-duplex mode. All ten RJ-45 ports
support Auto MDI/MDIX and can be used as ordinary ports or as Uplink
ports. Ports 1-8 are PoE+ and are enabled by default.
Use the included power cable to connect the XMS-1010P to a surge
protected outlet. The AC input socket and a power switch are on the rear
panel. The built-in power supply supports 100~240VAC at 50/60Hz.
Network Cabling
Luxul recommends Category-5, super Category-5 or Category-6 unshielded
twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and
stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair.
cCAUTION: Multiple Uplink channels can create loops, resulting in
network failure. Ensure only one Uplink channel exists
between switches or between the XMS-1010P and a router.
nNOTE: When powering up, the port LEDs corresponding to the opti-
cal interface may take a moment to initialize. This is normal
as the XMS-1010P initialization and startup completes.
nNOTE: The XMS-1010P has an internal 130W power supply. For
optimal switch performance, do not exceed 115W combined
consumption of all external PoE devices.
LEGAL AND REGULATORY INFORMATION
No part of this publication, or any other publication may be modified or
adapted in any way, for any purposes without permission in writing from
Luxul. The material in this manual is subject to change without notice. Luxul
reserves the right to make changes to any product to improve reliability,
function, or design. No license is granted, either expressly or by implication
or otherwise under any Luxul intellectual property rights. An implied license
only exists for equipment, circuits and subsystems contained in this or any
Luxul product.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah,
84020, declares that this Luxul XMS-1010P is in compliance with the
essential requirements and other relevant provisions of Directive
1995/5/EC.
For a copy of this report send a self addressed stamped envelope
to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4)
CAN ICES-3(B)/NMB-3(B)
Sales
P: 801-822-5450
Technical Support
P: 801-822-5450 Option 3
© 2016 Luxul. All Rights Reserved. LUX-QIG-XMS-1010P 0161609

READ ME FIRST
Fold Fold Fold
QUICK INSTALL GUIDE
10-Port/8 PoE+ Gigabit
Managed Switch
XMS-1010P
Includes:
XMS-1010P 10-Port/8 PoE+ Gigabit Managed Switch
Rack-mount hardware and rubber feet
Power cable
SETUP AND CONFIGURATION
1Physical Installation
The XMS-1010P can be rack-mounted or used as a desktop switch. Install the
XMS-1010P in a stable/safe place to avoid any possible damage. Make sure
there is adequate space around the XMS-1010P for ventilation and proper
heat dissipation; Luxul recommends at least 4-6 inches around all sides. Avoid
placement in direct sunlight. Do not place heavy articles on the XMS-1010P
and verify the ground connection of the outlet is functioning properly.
Desktop/Shelf Installation
For desktop/shelf installation, attach the four rubber feet to the corner inden-
tations on the bottom of the XMS-1010P, then place the switch horizontally
on a solid, level platform.
Rack Installation
Use the included L brackets for convenient installation in a 19-inch server or
audio rack. As shown below, use four screws to attach the L-shaped brackets
on either sides of the XMS-1010P, and horizontally insert the switch into the
rack. Use your desired hardware to affix the switch supports to the rack.
Attach feet for desktop installation Install brackets for rack-mounting
2Connecting Ethernet and Power
Ethernet and Power Connections
Use any RJ-45 to connect the XMS-1010P to an Ethernet-enabled device,
including servers, routers or other switches. No crossover cable is necessary.
The XMS-1010P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/
full-duplex mode and 1000 Mbps full-duplex mode. All ten RJ-45 ports
support Auto MDI/MDIX and can be used as ordinary ports or as Uplink
ports. Ports 1-8 are PoE+ and are enabled by default.
Use the included power cable to connect the XMS-1010P to a surge
protected outlet. The AC input socket and a power switch are on the rear
panel. The built-in power supply supports 100~240VAC at 50/60Hz.
Network Cabling
Luxul recommends Category-5, super Category-5 or Category-6 unshielded
twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and
stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair.
cCAUTION: Multiple Uplink channels can create loops, resulting in
network failure. Ensure only one Uplink channel exists
between switches or between the XMS-1010P and a router.
nNOTE: When powering up, the port LEDs corresponding to the opti-
cal interface may take a moment to initialize. This is normal
as the XMS-1010P initialization and startup completes.
nNOTE: The XMS-1010P has an internal 130W power supply. For
optimal switch performance, do not exceed 115W combined
consumption of all external PoE devices.
LEGAL AND REGULATORY INFORMATION
No part of this publication, or any other publication may be modified or
adapted in any way, for any purposes without permission in writing from
Luxul. The material in this manual is subject to change without notice. Luxul
reserves the right to make changes to any product to improve reliability,
function, or design. No license is granted, either expressly or by implication
or otherwise under any Luxul intellectual property rights. An implied license
only exists for equipment, circuits and subsystems contained in this or any
Luxul product.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah,
84020, declares that this Luxul XMS-1010P is in compliance with the
essential requirements and other relevant provisions of Directive
1995/5/EC.
For a copy of this report send a self addressed stamped envelope
to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4)
CAN ICES-3(B)/NMB-3(B)
Sales
P: 801-822-5450
Technical Support
P: 801-822-5450 Option 3
© 2016 Luxul. All Rights Reserved. LUX-QIG-XMS-1010P 0161609

READ ME FIRST
Fold Fold Fold
QUICK INSTALL GUIDE
10-Port/8 PoE+ Gigabit
Managed Switch
XMS-1010P
Includes:
XMS-1010P 10-Port/8 PoE+ Gigabit Managed Switch
Rack-mount hardware and rubber feet
Power cable
SETUP AND CONFIGURATION
1Physical Installation
The XMS-1010P can be rack-mounted or used as a desktop switch. Install the
XMS-1010P in a stable/safe place to avoid any possible damage. Make sure
there is adequate space around the XMS-1010P for ventilation and proper
heat dissipation; Luxul recommends at least 4-6 inches around all sides. Avoid
placement in direct sunlight. Do not place heavy articles on the XMS-1010P
and verify the ground connection of the outlet is functioning properly.
Desktop/Shelf Installation
For desktop/shelf installation, attach the four rubber feet to the corner inden-
tations on the bottom of the XMS-1010P, then place the switch horizontally
on a solid, level platform.
Rack Installation
Use the included L brackets for convenient installation in a 19-inch server or
audio rack. As shown below, use four screws to attach the L-shaped brackets
on either sides of the XMS-1010P, and horizontally insert the switch into the
rack. Use your desired hardware to affix the switch supports to the rack.
Attach feet for desktop installation Install brackets for rack-mounting
2Connecting Ethernet and Power
Ethernet and Power Connections
Use any RJ-45 to connect the XMS-1010P to an Ethernet-enabled device,
including servers, routers or other switches. No crossover cable is necessary.
The XMS-1010P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/
full-duplex mode and 1000 Mbps full-duplex mode. All ten RJ-45 ports
support Auto MDI/MDIX and can be used as ordinary ports or as Uplink
ports. Ports 1-8 are PoE+ and are enabled by default.
Use the included power cable to connect the XMS-1010P to a surge
protected outlet. The AC input socket and a power switch are on the rear
panel. The built-in power supply supports 100~240VAC at 50/60Hz.
Network Cabling
Luxul recommends Category-5, super Category-5 or Category-6 unshielded
twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and
stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair.
cCAUTION: Multiple Uplink channels can create loops, resulting in
network failure. Ensure only one Uplink channel exists
between switches or between the XMS-1010P and a router.
nNOTE: When powering up, the port LEDs corresponding to the opti-
cal interface may take a moment to initialize. This is normal
as the XMS-1010P initialization and startup completes.
nNOTE: The XMS-1010P has an internal 130W power supply. For
optimal switch performance, do not exceed 115W combined
consumption of all external PoE devices.
LEGAL AND REGULATORY INFORMATION
No part of this publication, or any other publication may be modified or
adapted in any way, for any purposes without permission in writing from
Luxul. The material in this manual is subject to change without notice. Luxul
reserves the right to make changes to any product to improve reliability,
function, or design. No license is granted, either expressly or by implication
or otherwise under any Luxul intellectual property rights. An implied license
only exists for equipment, circuits and subsystems contained in this or any
Luxul product.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah,
84020, declares that this Luxul XMS-1010P is in compliance with the
essential requirements and other relevant provisions of Directive
1995/5/EC.
For a copy of this report send a self addressed stamped envelope
to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4)
CAN ICES-3(B)/NMB-3(B)
Sales
P: 801-822-5450
Technical Support
P: 801-822-5450 Option 3
© 2016 Luxul. All Rights Reserved. LUX-QIG-XMS-1010P 0161609

Fold Fold Fold
3Preparing for Access
IP Addressing
If the XMS-1010P is connected to a network with a 192.168.0.X address
scheme, and your computer shares a similar address on the same network,
you can skip to the next step, Access and Setup.
nNote: If another device on your network shares the 192.168.0.3
address, you’ll need to temporarily reassign or remove that
device while you configure the XMS-1010P.
If your network uses an address scheme other than 192.168.0.X, you’ll
need to set a temporary static IP address on the computer you’re using for
configuration. To do so, set the IP address of your computer to an address
in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.3
(the default IP address of the XMS-1010P).
Once you’re finished configuring the switch, you can return your comput-
er’s IP configuration to normal, typically “Obtain Automatically/DHCP.”
nNote: Visit http://luxul.com/ip-addressing to learn more about
changing your computer’s IP address and getting connected.
4Access and Setup
Getting Connected
Use an Ethernet cable to connect your computer to the XMS-1010P, then
power on the switch.
Logging In
To access the XMS-1010P web configuration, open your web browser and enter
the switch’s default 192.168.0.3 IP address in the address field. Log in to the
switch using the default user name and password:
Default IP: 192.168.0.3
Username: admin
Password: admin
Select the menu items on the left to view and/or modify the configuration.
5Hardware Operation
The front panel of the XMS-1010P switch includes eight 10/100/1000 Mbps RJ-
45 PoE+ ports, two Gigabit uplink ports, and a set of LED indicators on the left
side. Each 1000 Mbps PoE+ port has one Link/Activity LED, one 1000 Mbps LED
and one PoE LED. There are also two uplink LEDs, one Power LED, one System
LED and a reset button.
XMS-1010P Front Panel
Status indicators
Each port has one Link/Activity LED, one 1000Mbps LED and one PoE LED. In
addition, there are two SFP LEDs, one Power LED, one System LED, and a Reset
button to reboot the device or restore factory default settings. The green LED
indicators show the working status of the switch. The following table describes
the LED functionality:
Indicator State Description
POWER On The XMS-1010P is switched on.
Off XMS-1010P is switched off or not connected to AC
power. Check power connections and power switch
at the back of the unit.
Link/Act On There is a device connected to the port.
Flashing Port is receiving or transmitting data.
Off No device is connected to the port.
1000 Mbps On A 1000 Mbps-capable device is connected.
Off No device is connected and/or the device is not
1000 Mbps-capable.
PoE On A PoE-enabled device is connected and the switch is
supplying power to the device.
Off No PoE-enabled device is connected or PoE is not
enabled on this port
SYSTEM On The XMS-1010P is booting.
Flashing The XMS-1010P is running normally.
Off The XMS-1010P is in startup and initialization process
or is not on.
At startup, port LEDs will flash for 1 second as a self test.
Reset Button
The Reset button (located at the lower-left corner of the front panel) is
used to reset (or reboot) the switch, or to restore the switch factory
default settings.
XTo Reset the Switch: With the XMS-1010P powered on, press the
Reset button.
cCAUTION: Do not hold the button for more than a second. Doing
so could erase all settings and restore factory defaults.
XTo Restore the Default Settings: With the XMS-1010P powered on,
press and hold the Reset button until the status of the System LED
shows the following: On – flashing – off. Once you see the flash
sequence, release the Reset button and the switch automatically
restores factory default settings. Once the System LED starts flashing
again, the XMS-1010P is set to factory defaults.
cCAUTION: Please note that restoring Default Settings will remove
any/all custom configuration.

Fold Fold Fold
3Preparing for Access
IP Addressing
If the XMS-1010P is connected to a network with a 192.168.0.X address
scheme, and your computer shares a similar address on the same network,
you can skip to the next step, Access and Setup.
nNote: If another device on your network shares the 192.168.0.3
address, you’ll need to temporarily reassign or remove that
device while you configure the XMS-1010P.
If your network uses an address scheme other than 192.168.0.X, you’ll
need to set a temporary static IP address on the computer you’re using for
configuration. To do so, set the IP address of your computer to an address
in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.3
(the default IP address of the XMS-1010P).
Once you’re finished configuring the switch, you can return your comput-
er’s IP configuration to normal, typically “Obtain Automatically/DHCP.”
nNote: Visit http://luxul.com/ip-addressing to learn more about
changing your computer’s IP address and getting connected.
4Access and Setup
Getting Connected
Use an Ethernet cable to connect your computer to the XMS-1010P, then
power on the switch.
Logging In
To access the XMS-1010P web configuration, open your web browser and enter
the switch’s default 192.168.0.3 IP address in the address field. Log in to the
switch using the default user name and password:
Default IP: 192.168.0.3
Username: admin
Password: admin
Select the menu items on the left to view and/or modify the configuration.
5Hardware Operation
The front panel of the XMS-1010P switch includes eight 10/100/1000 Mbps RJ-
45 PoE+ ports, two Gigabit uplink ports, and a set of LED indicators on the left
side. Each 1000 Mbps PoE+ port has one Link/Activity LED, one 1000 Mbps LED
and one PoE LED. There are also two uplink LEDs, one Power LED, one System
LED and a reset button.
XMS-1010P Front Panel
Status indicators
Each port has one Link/Activity LED, one 1000Mbps LED and one PoE LED. In
addition, there are two SFP LEDs, one Power LED, one System LED, and a Reset
button to reboot the device or restore factory default settings. The green LED
indicators show the working status of the switch. The following table describes
the LED functionality:
Indicator State Description
POWER On The XMS-1010P is switched on.
Off XMS-1010P is switched off or not connected to AC
power. Check power connections and power switch
at the back of the unit.
Link/Act On There is a device connected to the port.
Flashing Port is receiving or transmitting data.
Off No device is connected to the port.
1000 Mbps On A 1000 Mbps-capable device is connected.
Off No device is connected and/or the device is not
1000 Mbps-capable.
PoE On A PoE-enabled device is connected and the switch is
supplying power to the device.
Off No PoE-enabled device is connected or PoE is not
enabled on this port
SYSTEM On The XMS-1010P is booting.
Flashing The XMS-1010P is running normally.
Off The XMS-1010P is in startup and initialization process
or is not on.
At startup, port LEDs will flash for 1 second as a self test.
Reset Button
The Reset button (located at the lower-left corner of the front panel) is
used to reset (or reboot) the switch, or to restore the switch factory
default settings.
XTo Reset the Switch: With the XMS-1010P powered on, press the
Reset button.
cCAUTION: Do not hold the button for more than a second. Doing
so could erase all settings and restore factory defaults.
XTo Restore the Default Settings: With the XMS-1010P powered on,
press and hold the Reset button until the status of the System LED
shows the following: On – flashing – off. Once you see the flash
sequence, release the Reset button and the switch automatically
restores factory default settings. Once the System LED starts flashing
again, the XMS-1010P is set to factory defaults.
cCAUTION: Please note that restoring Default Settings will remove
any/all custom configuration.

Fold Fold Fold
3Preparing for Access
IP Addressing
If the XMS-1010P is connected to a network with a 192.168.0.X address
scheme, and your computer shares a similar address on the same network,
you can skip to the next step, Access and Setup.
nNote: If another device on your network shares the 192.168.0.3
address, you’ll need to temporarily reassign or remove that
device while you configure the XMS-1010P.
If your network uses an address scheme other than 192.168.0.X, you’ll
need to set a temporary static IP address on the computer you’re using for
configuration. To do so, set the IP address of your computer to an address
in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.3
(the default IP address of the XMS-1010P).
Once you’re finished configuring the switch, you can return your comput-
er’s IP configuration to normal, typically “Obtain Automatically/DHCP.”
nNote: Visit http://luxul.com/ip-addressing to learn more about
changing your computer’s IP address and getting connected.
4Access and Setup
Getting Connected
Use an Ethernet cable to connect your computer to the XMS-1010P, then
power on the switch.
Logging In
To access the XMS-1010P web configuration, open your web browser and enter
the switch’s default 192.168.0.3 IP address in the address field. Log in to the
switch using the default user name and password:
Default IP: 192.168.0.3
Username: admin
Password: admin
Select the menu items on the left to view and/or modify the configuration.
5Hardware Operation
The front panel of the XMS-1010P switch includes eight 10/100/1000 Mbps RJ-
45 PoE+ ports, two Gigabit uplink ports, and a set of LED indicators on the left
side. Each 1000 Mbps PoE+ port has one Link/Activity LED, one 1000 Mbps LED
and one PoE LED. There are also two uplink LEDs, one Power LED, one System
LED and a reset button.
XMS-1010P Front Panel
Status indicators
Each port has one Link/Activity LED, one 1000Mbps LED and one PoE LED. In
addition, there are two SFP LEDs, one Power LED, one System LED, and a Reset
button to reboot the device or restore factory default settings. The green LED
indicators show the working status of the switch. The following table describes
the LED functionality:
Indicator State Description
POWER On The XMS-1010P is switched on.
Off XMS-1010P is switched off or not connected to AC
power. Check power connections and power switch
at the back of the unit.
Link/Act On There is a device connected to the port.
Flashing Port is receiving or transmitting data.
Off No device is connected to the port.
1000 Mbps On A 1000 Mbps-capable device is connected.
Off No device is connected and/or the device is not
1000 Mbps-capable.
PoE On A PoE-enabled device is connected and the switch is
supplying power to the device.
Off No PoE-enabled device is connected or PoE is not
enabled on this port
SYSTEM On The XMS-1010P is booting.
Flashing The XMS-1010P is running normally.
Off The XMS-1010P is in startup and initialization process
or is not on.
At startup, port LEDs will flash for 1 second as a self test.
Reset Button
The Reset button (located at the lower-left corner of the front panel) is
used to reset (or reboot) the switch, or to restore the switch factory
default settings.
XTo Reset the Switch: With the XMS-1010P powered on, press the
Reset button.
cCAUTION: Do not hold the button for more than a second. Doing
so could erase all settings and restore factory defaults.
XTo Restore the Default Settings: With the XMS-1010P powered on,
press and hold the Reset button until the status of the System LED
shows the following: On – flashing – off. Once you see the flash
sequence, release the Reset button and the switch automatically
restores factory default settings. Once the System LED starts flashing
again, the XMS-1010P is set to factory defaults.
cCAUTION: Please note that restoring Default Settings will remove
any/all custom configuration.

Fold Fold Fold
3Preparing for Access
IP Addressing
If the XMS-1010P is connected to a network with a 192.168.0.X address
scheme, and your computer shares a similar address on the same network,
you can skip to the next step, Access and Setup.
nNote: If another device on your network shares the 192.168.0.3
address, you’ll need to temporarily reassign or remove that
device while you configure the XMS-1010P.
If your network uses an address scheme other than 192.168.0.X, you’ll
need to set a temporary static IP address on the computer you’re using for
configuration. To do so, set the IP address of your computer to an address
in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.3
(the default IP address of the XMS-1010P).
Once you’re finished configuring the switch, you can return your comput-
er’s IP configuration to normal, typically “Obtain Automatically/DHCP.”
nNote: Visit http://luxul.com/ip-addressing to learn more about
changing your computer’s IP address and getting connected.
4Access and Setup
Getting Connected
Use an Ethernet cable to connect your computer to the XMS-1010P, then
power on the switch.
Logging In
To access the XMS-1010P web configuration, open your web browser and enter
the switch’s default 192.168.0.3 IP address in the address field. Log in to the
switch using the default user name and password:
Default IP: 192.168.0.3
Username: admin
Password: admin
Select the menu items on the left to view and/or modify the configuration.
5Hardware Operation
The front panel of the XMS-1010P switch includes eight 10/100/1000 Mbps RJ-
45 PoE+ ports, two Gigabit uplink ports, and a set of LED indicators on the left
side. Each 1000 Mbps PoE+ port has one Link/Activity LED, one 1000 Mbps LED
and one PoE LED. There are also two uplink LEDs, one Power LED, one System
LED and a reset button.
XMS-1010P Front Panel
Status indicators
Each port has one Link/Activity LED, one 1000Mbps LED and one PoE LED. In
addition, there are two SFP LEDs, one Power LED, one System LED, and a Reset
button to reboot the device or restore factory default settings. The green LED
indicators show the working status of the switch. The following table describes
the LED functionality:
Indicator State Description
POWER On The XMS-1010P is switched on.
Off XMS-1010P is switched off or not connected to AC
power. Check power connections and power switch
at the back of the unit.
Link/Act On There is a device connected to the port.
Flashing Port is receiving or transmitting data.
Off No device is connected to the port.
1000 Mbps On A 1000 Mbps-capable device is connected.
Off No device is connected and/or the device is not
1000 Mbps-capable.
PoE On A PoE-enabled device is connected and the switch is
supplying power to the device.
Off No PoE-enabled device is connected or PoE is not
enabled on this port
SYSTEM On The XMS-1010P is booting.
Flashing The XMS-1010P is running normally.
Off The XMS-1010P is in startup and initialization process
or is not on.
At startup, port LEDs will flash for 1 second as a self test.
Reset Button
The Reset button (located at the lower-left corner of the front panel) is
used to reset (or reboot) the switch, or to restore the switch factory
default settings.
XTo Reset the Switch: With the XMS-1010P powered on, press the
Reset button.
cCAUTION: Do not hold the button for more than a second. Doing
so could erase all settings and restore factory defaults.
XTo Restore the Default Settings: With the XMS-1010P powered on,
press and hold the Reset button until the status of the System LED
shows the following: On – flashing – off. Once you see the flash
sequence, release the Reset button and the switch automatically
restores factory default settings. Once the System LED starts flashing
again, the XMS-1010P is set to factory defaults.
cCAUTION: Please note that restoring Default Settings will remove
any/all custom configuration.

READ ME FIRST
Fold Fold Fold
QUICK INSTALL GUIDE
10-Port/8 PoE+ Gigabit
Managed Switch
XMS-1010P
Includes:
XMS-1010P 10-Port/8 PoE+ Gigabit Managed Switch
Rack-mount hardware and rubber feet
Power cable
SETUP AND CONFIGURATION
1Physical Installation
The XMS-1010P can be rack-mounted or used as a desktop switch. Install the
XMS-1010P in a stable/safe place to avoid any possible damage. Make sure
there is adequate space around the XMS-1010P for ventilation and proper
heat dissipation; Luxul recommends at least 4-6 inches around all sides. Avoid
placement in direct sunlight. Do not place heavy articles on the XMS-1010P
and verify the ground connection of the outlet is functioning properly.
Desktop/Shelf Installation
For desktop/shelf installation, attach the four rubber feet to the corner inden-
tations on the bottom of the XMS-1010P, then place the switch horizontally
on a solid, level platform.
Rack Installation
Use the included L brackets for convenient installation in a 19-inch server or
audio rack. As shown below, use four screws to attach the L-shaped brackets
on either sides of the XMS-1010P, and horizontally insert the switch into the
rack. Use your desired hardware to affix the switch supports to the rack.
Attach feet for desktop installation Install brackets for rack-mounting
2Connecting Ethernet and Power
Ethernet and Power Connections
Use any RJ-45 to connect the XMS-1010P to an Ethernet-enabled device,
including servers, routers or other switches. No crossover cable is necessary.
The XMS-1010P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/
full-duplex mode and 1000 Mbps full-duplex mode. All ten RJ-45 ports
support Auto MDI/MDIX and can be used as ordinary ports or as Uplink
ports. Ports 1-8 are PoE+ and are enabled by default.
Use the included power cable to connect the XMS-1010P to a surge
protected outlet. The AC input socket and a power switch are on the rear
panel. The built-in power supply supports 100~240VAC at 50/60Hz.
Network Cabling
Luxul recommends Category-5, super Category-5 or Category-6 unshielded
twisted pair (CAT5/CAT5e/CAT6 UTP). To ensure best performance and
stable data transmission at 1000 Mbps, use Category-6 shielded twisted pair.
cCAUTION: Multiple Uplink channels can create loops, resulting in
network failure. Ensure only one Uplink channel exists
between switches or between the XMS-1010P and a router.
nNOTE: When powering up, the port LEDs corresponding to the opti-
cal interface may take a moment to initialize. This is normal
as the XMS-1010P initialization and startup completes.
nNOTE: The XMS-1010P has an internal 130W power supply. For
optimal switch performance, do not exceed 115W combined
consumption of all external PoE devices.
LEGAL AND REGULATORY INFORMATION
No part of this publication, or any other publication may be modified or
adapted in any way, for any purposes without permission in writing from
Luxul. The material in this manual is subject to change without notice. Luxul
reserves the right to make changes to any product to improve reliability,
function, or design. No license is granted, either expressly or by implication
or otherwise under any Luxul intellectual property rights. An implied license
only exists for equipment, circuits and subsystems contained in this or any
Luxul product.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah,
84020, declares that this Luxul XMS-1010P is in compliance with the
essential requirements and other relevant provisions of Directive
1995/5/EC.
For a copy of this report send a self addressed stamped envelope
to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4)
CAN ICES-3(B)/NMB-3(B)
Sales
P: 801-822-5450
Technical Support
P: 801-822-5450 Option 3
© 2016 Luxul. All Rights Reserved. LUX-QIG-XMS-1010P 0161609
Table of contents
Other Luxul Switch manuals

Luxul
Luxul XFS-1084P User manual

Luxul
Luxul AMS-1208P User manual

Luxul
Luxul AMS-2600 User manual

Luxul
Luxul XMS-2624P User manual

Luxul
Luxul XMS-1008P User manual

Luxul
Luxul AMS-4424P User manual

Luxul
Luxul XMS-5248P User manual

Luxul
Luxul XFS-1084P User manual

Luxul
Luxul XGS-1005 User manual

Luxul
Luxul XGS-1024 User manual

Luxul
Luxul XVS-F5 User manual

Luxul
Luxul XMS-1008P User manual

Luxul
Luxul AGS-1024 User manual

Luxul
Luxul AGS-1024 User manual

Luxul
Luxul AMS-1208P User manual

Luxul
Luxul AMS-2624P-E User manual

Luxul
Luxul AMS-1208P User manual

Luxul
Luxul AMS-4424P User manual

Luxul
Luxul Xen XGS-1008 User manual

Luxul
Luxul AMS-1208P User manual