manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R3-PA8 User manual

M-system R3-PA8 User manual

R3-PA8
P. 1 / 3EM-8457
TOTALIZED PULSE INPUT MODULE
(Pi 8 points, 32 Bits) MODEL R3-PA8
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
Totalized pulse input module....................................... (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-PA8
P. 2 / 3EM-8457
The bits indicating the channels to reset counter are allocated in the first word from host PC/PLC.
When these bits are changed from 0 to 1, the counter is reset. When it is confirmed that the counter is reset, return to 0.
Notice that if the bit remains at 1, the next reset will not work.
0
15
Count reset CH.1
Unused
Unused
Count reset CH.2
Count reset CH.3
Count reset CH.4
Count reset CH.8
BIT ALLOCATION OF THE FIRST WORD FROM HOST PC/PLC
COMPONENT IDENTIFICATION
RUN LED
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ERR LED
Status Indicator LED
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
■ FRONT VIEW ■ SIDE VIEW
SW3
ON
4
3
2
1Count
Reset
Count
Reset Input
Set the Count Reset SW to OFF to start counting.
Functions
■ STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the excitation abnormality;
Green in normal operating conditions.
Input status indicator: Red LED;
1 to 8: Turns on with the inputs supplied.
9 to 15: Unused*
16: Turns on with the reset input supplied.
*The LEDs are connected with terminals via internal cir-
cuit. Therefore, the LED turns on, if the corresponding ter-
minal is connected to terminal 10 or 20. However, it does
not affect the operation.
R3-PA8
P. 3 / 3EM-8457
WIRING INSTRUCTIONS
■ SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit. Applicable
wire size: 0.3 – 0.5 mm2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
10
20
1
5
2
3
6
4
7
13
8
11
14
12
15
9
16
17
18
Pi 1
Pi 2
Pi 3
Pi 4
Pi 5
Pi 6
Pi 7
Pi 8
19
COM(
+)
0V
10
20
1
5
2
3
6
4
7
13
8
11
14
12
15
9
16
17
18
Pi 1
Pi 2
Pi 3
Pi 4
Pi 5
Pi 6
Pi 7
Pi 8
19
0V
� R3-PA8x/A
� R3-PA8x
+24V
**
INTERNAL
POWER
BUS A
BUS B
BUS CONNECTOR
Numbers in italic indicate LED No.s assigned to
the front panel LEDs.
*For dual redundant communication.
**DO NOT use the terminals No. 9, 11 through 17 and 19.
Count
Reset
Count
Reset
*
****
■ DIMENSIONS mm (inch)
■ CONNECTION DIAGRAM
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

Other M-system Control Unit manuals

M-system R7L-EC16B User manual

M-system

M-system R7L-EC16B User manual

M-system 73VR3100 User manual

M-system

M-system 73VR3100 User manual

M-system R7M-TS4 User manual

M-system

M-system R7M-TS4 User manual

M-system M6NPS2 User manual

M-system

M-system M6NPS2 User manual

M-system R7C-EC8A User manual

M-system

M-system R7C-EC8A User manual

M-system Devicenet R7F4HD-DAC32D User manual

M-system

M-system Devicenet R7F4HD-DAC32D User manual

M-system R80ND2 User manual

M-system

M-system R80ND2 User manual

M-system R7ML-DC16A User manual

M-system

M-system R7ML-DC16A User manual

M-system R7ML-EC16D User manual

M-system

M-system R7ML-EC16D User manual

M-system R7D-EA8 User manual

M-system

M-system R7D-EA8 User manual

M-system R3-RR8 User manual

M-system

M-system R3-RR8 User manual

M-system M6SXF2 User manual

M-system

M-system M6SXF2 User manual

M-system Mini-M M2MNV User manual

M-system

M-system Mini-M M2MNV User manual

M-system R7M-DA16 User manual

M-system

M-system R7M-DA16 User manual

M-system R7ML-EC16B User manual

M-system

M-system R7ML-EC16B User manual

M-system R8-FS16N User manual

M-system

M-system R8-FS16N User manual

M-system R8-DCM16ALK User manual

M-system

M-system R8-DCM16ALK User manual

M-system R8-DC4C User manual

M-system

M-system R8-DC4C User manual

M-system R7M-EC8A/UL User manual

M-system

M-system R7M-EC8A/UL User manual

M-system R30CT4E User manual

M-system

M-system R30CT4E User manual

M-system R7ML-EA16 User manual

M-system

M-system R7ML-EA16 User manual

M-system R3-SV8C User manual

M-system

M-system R3-SV8C User manual

M-system R3-PD16A User manual

M-system

M-system R3-PD16A User manual

M-system R7ML-DC16B User manual

M-system

M-system R7ML-DC16B User manual

Popular Control Unit manuals by other brands

GEM B52 operating instructions

GEM

GEM B52 operating instructions

Spears TRUE UNION 2000 Series manual

Spears

Spears TRUE UNION 2000 Series manual

Trust SMART Home 71110 Configuration

Trust

Trust SMART Home 71110 Configuration

Leviton 73A00-4ZB Installation instructions and user guide

Leviton

Leviton 73A00-4ZB Installation instructions and user guide

FLIR ACCKBD320 instruction manual

FLIR

FLIR ACCKBD320 instruction manual

VAT 650 TJ Series Installation, operating,  & maintenance instructions

VAT

VAT 650 TJ Series Installation, operating, & maintenance instructions

Tunstall Macon STV Series manual

Tunstall

Tunstall Macon STV Series manual

Aim GPS09c quick guide

Aim

Aim GPS09c quick guide

Kolver EDU2AE/FR Operational manual

Kolver

Kolver EDU2AE/FR Operational manual

Lenze SM100 E94AYAB manual

Lenze

Lenze SM100 E94AYAB manual

Fuji Electric M653 Series Mounting instruction

Fuji Electric

Fuji Electric M653 Series Mounting instruction

Siemens SIMATIC ET 200eco PN Equipment manual

Siemens

Siemens SIMATIC ET 200eco PN Equipment manual

Hasco GU60000 owner's manual

Hasco

Hasco GU60000 owner's manual

Hydrolevel Company VXT-120 quick guide

Hydrolevel Company

Hydrolevel Company VXT-120 quick guide

Burkert 6228 operating instructions

Burkert

Burkert 6228 operating instructions

BENDIX M-40QR Service data

BENDIX

BENDIX M-40QR Service data

ABB COM600 series user guide

ABB

ABB COM600 series user guide

Datakom DKG-519 user manual

Datakom

Datakom DKG-519 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.