EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R3-PA8 User manual

M-system R3-PA8 User manual

Other M-system Control Unit manuals

M-system R3-NF2 User manual

M-system

M-system R3-NF2 User manual

M-system R7M-EA16 User manual

M-system

M-system R7M-EA16 User manual

M-system R8-NECT1 User manual

M-system

M-system R8-NECT1 User manual

M-system R7ML-EC8A User manual

M-system

M-system R7ML-EC8A User manual

M-system R7L-EC8B User manual

M-system

M-system R7L-EC8B User manual

M-system R7EWTU User manual

M-system

M-system R7EWTU User manual

M-system R7ML-YV2 User manual

M-system

M-system R7ML-YV2 User manual

M-system F2DL User manual

M-system

M-system F2DL User manual

M-system R7M-EC8B/UL User manual

M-system

M-system R7M-EC8B/UL User manual

M-system R6-PSM User manual

M-system

M-system R6-PSM User manual

M-system R7HL-DAC15E User manual

M-system

M-system R7HL-DAC15E User manual

M-system Mini-M M2MNV User manual

M-system

M-system Mini-M M2MNV User manual

M-system M6NPS2 User manual

M-system

M-system M6NPS2 User manual

M-system R7D-EA8 User manual

M-system

M-system R7D-EA8 User manual

M-system R7M-YV2-R User manual

M-system

M-system R7M-YV2-R User manual

M-system R7ML-EC16A User manual

M-system

M-system R7ML-EC16A User manual

M-system R7C-EC8A User manual

M-system

M-system R7C-EC8A User manual

M-system R7M-MS4 User manual

M-system

M-system R7M-MS4 User manual

M-system R3-SV8B User manual

M-system

M-system R3-SV8B User manual

M-system R7G4HEIP-6-DC16B User manual

M-system

M-system R7G4HEIP-6-DC16B User manual

M-system R7L-EC8A User manual

M-system

M-system R7L-EC8A User manual

M-system R7M-EC16A User manual

M-system

M-system R7M-EC16A User manual

M-system R3Y-DS8N User manual

M-system

M-system R3Y-DS8N User manual

M-system R7M-YV2 User manual

M-system

M-system R7M-YV2 User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

R3-PA8
P. 1 / 3EM-8457
TOTALIZED PULSE INPUT MODULE
(Pi 8 points, 32 Bits) MODEL R3-PA8
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
Totalized pulse input module....................................... (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-PA8
P. 2 / 3EM-8457
The bits indicating the channels to reset counter are allocated in the first word from host PC/PLC.
When these bits are changed from 0 to 1, the counter is reset. When it is confirmed that the counter is reset, return to 0.
Notice that if the bit remains at 1, the next reset will not work.
0
15
Count reset CH.1
Unused
Unused
Count reset CH.2
Count reset CH.3
Count reset CH.4
Count reset CH.8
BIT ALLOCATION OF THE FIRST WORD FROM HOST PC/PLC
COMPONENT IDENTIFICATION
RUN LED
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ERR LED
Status Indicator LED
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
■ FRONT VIEW ■ SIDE VIEW
SW3
ON
4
3
2
1Count
Reset
Count
Reset Input
Set the Count Reset SW to OFF to start counting.
Functions
■ STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the excitation abnormality;
Green in normal operating conditions.
Input status indicator: Red LED;
1 to 8: Turns on with the inputs supplied.
9 to 15: Unused*
16: Turns on with the reset input supplied.
*The LEDs are connected with terminals via internal cir-
cuit. Therefore, the LED turns on, if the corresponding ter-
minal is connected to terminal 10 or 20. However, it does
not affect the operation.
R3-PA8
P. 3 / 3EM-8457
WIRING INSTRUCTIONS
■ SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit. Applicable
wire size: 0.3 – 0.5 mm2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
10
20
1
5
2
3
6
4
7
13
8
11
14
12
15
9
16
17
18
Pi 1
Pi 2
Pi 3
Pi 4
Pi 5
Pi 6
Pi 7
Pi 8
19
COM(
+)
0V
10
20
1
5
2
3
6
4
7
13
8
11
14
12
15
9
16
17
18
Pi 1
Pi 2
Pi 3
Pi 4
Pi 5
Pi 6
Pi 7
Pi 8
19
0V
� R3-PA8x/A
� R3-PA8x
+24V
**
INTERNAL
POWER
BUS A
BUS B
BUS CONNECTOR
Numbers in italic indicate LED No.s assigned to
the front panel LEDs.
*For dual redundant communication.
**DO NOT use the terminals No. 9, 11 through 17 and 19.
Count
Reset
Count
Reset
*
****
■ DIMENSIONS mm (inch)
■ CONNECTION DIAGRAM
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]