EM-5424 Rev.6 P. 1 / 2
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside a panel.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
• Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 80mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 30 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Zero Adj.
Span Adj.
Connection
Diagram
Specifications
Euro Type
Connector Terminal Block
INSTALLATION
Set the unit so that its DIN rail adaptor is at the bottom.
Hang the upper hook at the rear side of the unit on the DIN
rail and push in the lower. When removing the unit, push
down the DIN rail adaptor utilizing a minus screwdriver
and pull.
DIN Rail
35 mm wide
Spring Loaded
DIN Rail Adaptor
CURRENT LOOP SUPPLY
(with square root extractor; non-isolated) MODEL F2DL
F2DL
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5424 Rev.6 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm (inch)
1234
5678
107 (4.21) [1.5 (.06)]
DIN RAIL
35mm wide
22.5 (.89)
75 (2.95)
• When mounting, no extra space is needed between units.
■CONNECTION DIAGRAM
+
–
+
–
OUTPUT
3
5
6
POWER
7
8
+
–
+
–
2
4
1
–
+
MONITOR
(4 – 20mA DC)
mA
2-WIRE
TRANSMITTER
WIRING INSTRUCTIONS
■EURO TYPE CONNECTOR TERMINAL
Applicable wire size: 0.2 to 2.5 mm2
Stripped length: 7 mm
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
7 – 8 with a multimeter.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 30 minutes.
1) ZERO: Apply 1% input and adjust output to 10%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 1% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 30 minutes. Apply 0%, 4%,
16%, 36%, 64% and 100% input signal. Check that the out-
put signal for the respective input signal shows 0%, 20%,
40%, 60%, 80% and 100% within accuracy described in the
data sheet. When the output is out of tolerance, recalibrate
the unit according to the “ADJUSTMENT PROCEDURE”
explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.

Other M-system Control Unit manuals

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7M-DA16 User manual

M-system

M-system R7M-DA16 User manual

M-system EtherCAT R30GECT1 User manual

M-system

M-system EtherCAT R30GECT1 User manual

M-system R7M-EC16B User manual

M-system

M-system R7M-EC16B User manual

M-system R3-NC3 User manual

M-system

M-system R3-NC3 User manual

M-system R7L-EC16B User manual

M-system

M-system R7L-EC16B User manual

M-system R30CT4E User manual

M-system

M-system R30CT4E User manual

M-system R6-NE1 User manual

M-system

M-system R6-NE1 User manual

M-system R3Y-SS8N User manual

M-system

M-system R3Y-SS8N User manual

M-system R7C-EC8A User manual

M-system

M-system R7C-EC8A User manual

M-system R8-DCM16ALK User manual

M-system

M-system R8-DCM16ALK User manual

M-system R3Y-SS8 User manual

M-system

M-system R3Y-SS8 User manual

M-system R7L-DA16-R User manual

M-system

M-system R7L-DA16-R User manual

M-system R7ML-EA16 User manual

M-system

M-system R7ML-EA16 User manual

M-system R3-PA4B User manual

M-system

M-system R3-PA4B User manual

M-system R7M-EC8B/UL User manual

M-system

M-system R7M-EC8B/UL User manual

M-system R7ML-EC16A User manual

M-system

M-system R7ML-EC16A User manual

M-system R7C-YS2 User manual

M-system

M-system R7C-YS2 User manual

M-system R7M-TS4 User manual

M-system

M-system R7M-TS4 User manual

M-system R7M-YV2-R User manual

M-system

M-system R7M-YV2-R User manual

M-system R7E-DC16B User manual

M-system

M-system R7E-DC16B User manual

M-system R7L-SV4-R User manual

M-system

M-system R7L-SV4-R User manual

M-system R3-NEIP1 User manual

M-system

M-system R3-NEIP1 User manual

M-system M8CD1 User manual

M-system

M-system M8CD1 User manual

Popular Control Unit manuals by other brands

TERMA MOA user manual

TERMA

TERMA MOA user manual

ABB SmissLine TP ZLS 260 Mounting instruction

ABB

ABB SmissLine TP ZLS 260 Mounting instruction

IME Nemo 96HDLe Mounting instructions

IME

IME Nemo 96HDLe Mounting instructions

Fluidmaster 400A installation instructions

Fluidmaster

Fluidmaster 400A installation instructions

Ingersoll-Rand RR250-F30 Installation and maintenance information

Ingersoll-Rand

Ingersoll-Rand RR250-F30 Installation and maintenance information

Stahl IS1+ operating instructions

Stahl

Stahl IS1+ operating instructions

Bandini Industrie GiBiDi CB24 Instructions for installations

Bandini Industrie

Bandini Industrie GiBiDi CB24 Instructions for installations

Viega PureFlow 2842.3ZL Product instructions

Viega

Viega PureFlow 2842.3ZL Product instructions

Vaillant VR 70 installation instructions

Vaillant

Vaillant VR 70 installation instructions

Nibe SMS 40 Installer manual

Nibe

Nibe SMS 40 Installer manual

Samson EB 01b Mounting and operating instructions

Samson

Samson EB 01b Mounting and operating instructions

jbc FAE900 manual

jbc

jbc FAE900 manual

Festo CPX-CMAX-C1-1 Brief description

Festo

Festo CPX-CMAX-C1-1 Brief description

VIPA System 300S manual

VIPA

VIPA System 300S manual

Enclustra Mercury SA1 SoC Module user manual

Enclustra

Enclustra Mercury SA1 SoC Module user manual

Epec 5050 Technical document

Epec

Epec 5050 Technical document

american flame AFVK-SP Installation and operating instructions

american flame

american flame AFVK-SP Installation and operating instructions

National Instruments NI 9265 Getting started guide

National Instruments

National Instruments NI 9265 Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.