manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R6-PSM User manual

M-system R6-PSM User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7781-BZ Rev.2 P. 1 / 2
INSTRUCTION MANUAL
POWER SUPPLY MODULE MODEL R6-PSM
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Power supply module ..........................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
•This equipment is suitable for Installation Category II
(transient voltage 2500V), Measurement Category II
(RUN contact output, transient voltage 2500V) and Polu-
tion Degree 2.
•Reinforced insulation (internal power or RUN contact
output to power input to FG: 300V) and basic insulation
(internal power to RUN contact output: 300V) are main-
tained. Prior to installation, check that the insulation
class of this unit satisfies the system requirements.
•The equipment must be mounted inside a panel.
•Altitude up to 2000 meters.
•The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
•The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
•Install lightning surge protectors for those wires connect-
ed to remote locations.
■POWER INPUT RATING & OPERATIONAL RANGE
•Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V AC rating: 90 – 264V, 47 – 66 Hz,
approx. 35VA
■GENERAL PRECAUTIONS
•Before you remove the unit from its base or mount it, turn
off the power supply for safety.
■ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
•Be sure that the ventilation slits are not covered with ca-
bles, etc.
•Keep space of at less 1 cm (0.4 inches) on the left side of
the power supply.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
456
123
POWER
Power LED
Connector Euro type
terminal block
■INDICATOR LED
ID COLOR FUNCTION
Power OFF Power supply off
Green ON Power supply on
Abnormal communication
Orange ON Power supply on
Normal communication status
INSTALLATION
Use the Installation Base (model: R6x-BS8B).
In order to remove this module from a base, push the lock-
ing clamp with a minus screwdriver.
R6-PSM
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7781-BZ Rev.2 P. 2 / 2
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
456
123
18 (0.71)
90 (3.54)
6.5 (.26) 90 (3.54)
5.6 (.22)
LOCKING CLAMP
POSITIONING GUIDE
■CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG
terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.
INTERNAL
POWER
1
2
4
5
INTERNAL
BUS
V
U
FG
POWER INPUT
RUN+
RUN–
RUN CONTACT OUTPUT
3
BUS CONNECTOR
■WIRING INSTRUCTIONS
Applicable wire size: 0.2 to 2.5 mm2(AWG24 to 12)
Stripped length: 7 mm
(Tinning wire ends may cause contact failure and therefore
is not recommended.)
CURRENT CONSUMPTION
The network module and I/O modules operate with 24 V DC
power supply via the power supply module. The total cur-
rent consumption of the network module and I/O modules
is required to be not more than the continuance output cur-
rent (400 mA) of the power supply module. If the total cur-
rent consumption exceeds the capacity of the power supply
module, change the combination of I/O modules or reduce
the number of I/O modules.
MODEL NO. MAX. CURRENT (mA)
R6x-SV2 20
R6x-SS2 20
R6x-TS2 20
R6x-TS2A 20
R6x-RS2 20
R6x-DS1 55
R6x-YV2 25
R6x-YS2 45
R6x-DA4 10
R6x-DC4A 20
R6x-DC4B 20
R6-NC1 110
R6-NC3 110
R6-ND1 40
R6-NE1 75
R6-NE2 75
R6-NM1 50
R6-NM2 50
R6-NF1 100
R6-NP1 100
RUN CONTACT OUTPUT
Terminals (4 – 5) turns on in normal communications with
the host PLC.
Terminals (4 – 5) turns off in an abnormal communication
status.

Other M-system Control Unit manuals

M-system EtherCAT R7I4DECT-1-PA8A User manual

M-system

M-system EtherCAT R7I4DECT-1-PA8A User manual

M-system M6NPS1 User manual

M-system

M-system M6NPS1 User manual

M-system M8CD1 User manual

M-system

M-system M8CD1 User manual

M-system R30MS4 User manual

M-system

M-system R30MS4 User manual

M-system R7L-EC16A User manual

M-system

M-system R7L-EC16A User manual

M-system R7M-YS2 User manual

M-system

M-system R7M-YS2 User manual

M-system R3-NMW1F User manual

M-system

M-system R3-NMW1F User manual

M-system R30SV2 User manual

M-system

M-system R30SV2 User manual

M-system R7M-EC8A User manual

M-system

M-system R7M-EC8A User manual

M-system R3Y-SV8 User manual

M-system

M-system R3Y-SV8 User manual

M-system R7D-EC8B User manual

M-system

M-system R7D-EC8B User manual

M-system 61A User manual

M-system

M-system 61A User manual

M-system Devicenet R7F4HD-DAC32D User manual

M-system

M-system Devicenet R7F4HD-DAC32D User manual

M-system R7M-CT4E User manual

M-system

M-system R7M-CT4E User manual

M-system R7E-DC16A User manual

M-system

M-system R7E-DC16A User manual

M-system R7C-DC16A User manual

M-system

M-system R7C-DC16A User manual

M-system R8-DCM16ALK User manual

M-system

M-system R8-DCM16ALK User manual

M-system R7M-TS4 User manual

M-system

M-system R7M-TS4 User manual

M-system R7L-EC8B User manual

M-system

M-system R7L-EC8B User manual

M-system R3-NC3 User manual

M-system

M-system R3-NC3 User manual

M-system R3-PS3 User manual

M-system

M-system R3-PS3 User manual

M-system R7C-RS4 User manual

M-system

M-system R7C-RS4 User manual

M-system Devicenet R7F4HD-DAC32C User manual

M-system

M-system Devicenet R7F4HD-DAC32C User manual

M-system R5-PA2 User manual

M-system

M-system R5-PA2 User manual

Popular Control Unit manuals by other brands

Ceta 104 operating manual

Ceta

Ceta 104 operating manual

BENDIX TW-12 CONTROL VALVE manual

BENDIX

BENDIX TW-12 CONTROL VALVE manual

Matrix Orbital LK202-24-USB Technical manual

Matrix Orbital

Matrix Orbital LK202-24-USB Technical manual

FAS FNI MPL-508-105-M user manual

FAS

FAS FNI MPL-508-105-M user manual

Spirax Sarco SRV66HC Installation and maintenance instructions

Spirax Sarco

Spirax Sarco SRV66HC Installation and maintenance instructions

Danfoss SFA 10 Service guide/Repair kit installation

Danfoss

Danfoss SFA 10 Service guide/Repair kit installation

Finn HydroSeeder T90 Technical bulletin

Finn

Finn HydroSeeder T90 Technical bulletin

Exhausto OJ GreenZone instructions

Exhausto

Exhausto OJ GreenZone instructions

Voxx 8812 quick start guide

Voxx

Voxx 8812 quick start guide

ARI D-060 Installation, operation and maintenance

ARI

ARI D-060 Installation, operation and maintenance

Honeywell NOTIFIER M710E-CZ installation instructions

Honeywell

Honeywell NOTIFIER M710E-CZ installation instructions

QuietCool IT-36002 owner's guide

QuietCool

QuietCool IT-36002 owner's guide

LEGRAND 675 07 quick start guide

LEGRAND

LEGRAND 675 07 quick start guide

Wireless-tag WT51 Series quick start

Wireless-tag

Wireless-tag WT51 Series quick start

Brigade UDS-OSD-20 Quick installation guide

Brigade

Brigade UDS-OSD-20 Quick installation guide

Burkert 3281 operating instructions

Burkert

Burkert 3281 operating instructions

Seneca Z113S manual

Seneca

Seneca Z113S manual

ACM SPOT Instructions and warnings for fitters

ACM

ACM SPOT Instructions and warnings for fitters

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.