manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Control Unit
  8. •
  9. M-system R3-SV8B User manual

M-system R3-SV8B User manual

Other M-system Control Unit manuals

M-system R7M-TS4 User manual

M-system

M-system R7M-TS4 User manual

M-system R3-SV8C User manual

M-system

M-system R3-SV8C User manual

M-system R5-PA2 User manual

M-system

M-system R5-PA2 User manual

M-system R7M-EC8B/UL User manual

M-system

M-system R7M-EC8B/UL User manual

M-system R3-SV4B User manual

M-system

M-system R3-SV4B User manual

M-system R7M-YS2 User manual

M-system

M-system R7M-YS2 User manual

M-system R7M-EC8C User manual

M-system

M-system R7M-EC8C User manual

M-system R7HL-DC16B-R User manual

M-system

M-system R7HL-DC16B-R User manual

M-system R8-NECT1 User manual

M-system

M-system R8-NECT1 User manual

M-system R7M-DC4G User manual

M-system

M-system R7M-DC4G User manual

M-system R30MS4 User manual

M-system

M-system R30MS4 User manual

M-system R7E-DC16A User manual

M-system

M-system R7E-DC16A User manual

M-system R7L-RR8 User manual

M-system

M-system R7L-RR8 User manual

M-system R7M-DC16A User manual

M-system

M-system R7M-DC16A User manual

M-system R7C-EC8A User manual

M-system

M-system R7C-EC8A User manual

M-system R7D-DA16 User manual

M-system

M-system R7D-DA16 User manual

M-system R7C-EC8B/UL User manual

M-system

M-system R7C-EC8B/UL User manual

M-system R3-PA4 User manual

M-system

M-system R3-PA4 User manual

M-system R3-PD16B User manual

M-system

M-system R3-PD16B User manual

M-system R7ML-EC16B User manual

M-system

M-system R7ML-EC16B User manual

M-system R7M-EC16B User manual

M-system

M-system R7M-EC16B User manual

M-system R5-NE1 User manual

M-system

M-system R5-NE1 User manual

M-system R3-PA8 User manual

M-system

M-system R3-PA8 User manual

M-system R7HL-DAC16C User manual

M-system

M-system R7HL-DAC16C User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8414 Rev.5 P. 1 / 3
INSTRUCTION MANUAL
DC VOLTAGE INPUT MODULE
(8 points, isolated, wide span voltage) MODEL R3-SV8B
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
DC voltage input module ....................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■UNUSED INPUT CHANNELS
• Set the unused channels to open. Otherwise, set them as
“Unused” with PC Configurator software: R3CON.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-SV8B
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8414 Rev.5 P. 2 / 3
COMPONENT IDENTIFICATION
SW2SW1
ON
1
2
3
4
5
6
7
8
ON
ON
1
2
3
4
5
6
7
8
SW3
1
2
3
4
5
19
20
21
22
15
16
17
18
23
24
25
26
27
28
6
7
8
9
10
11
12
13
14
1
2
3
4
■ FRONT VIEW
ERR LED
RUN LED
■ SIDE VIEW
Range
Input 1-4 (SW1)
or
Input 5-8 (SW2)
Conv.
Rate
Functions
■SIDE DIP SW
(*) Factory setting
• Input Range: SW1, SW2 (selectable per 4 channels)
INPUT 1 through INPUT 4 (SW1)
RANGEINPUT 5 through INPUT 8 (SW2)
1234
OFF OFF OFF OFF -30 – +30V (*)
ON OFF OFF OFF -15 – +15V
OFF ON OFF OFF 0 – 30V
ON ON OFF OFF 0 – 15V
• Conversion Rate: SW3-1, 3-2
SW CONVERSION RATE
160 ms (*)80 ms 40 ms 20 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
Note: Be sure to set unused SW1-5 through 1-8, SW2-5
through 2-8, SW3-3 and 3-4 to OFF.
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with input circuit abnormality (AD con-
verter response failure);
Green in normal operating conditions.
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Unused 0: Enable
1: Disable
0: Enable
R3-SV8B
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8414 Rev.5 P. 3 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
TERMINAL
COVER
5
19
20
21
22
15
16
17
18
23
24
25
26
27
28
6
7
8
9
10
11
12
13
14
1
2
3
4
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
28–M3
SCREW
6.2
(.24)
■CONNECTION DIAGRAM
*For dual redundant communication.
DO NOT connect external wiring to the unused terminals.
BUS CONNECTOR
1
3
–
INPUT 1
+
4
6
–
INPUT 2
+
7
9
–
INPUT 3
+
10
12
–
INPUT 4
+
15
17
–
INPUT 5
+
18
20
–
INPUT 6
+
21
23
–
INPUT 7
+
24
26
–
INPUT 8
+
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.5 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)