M-system 18AC User manual

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 35mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 18BXx or 18KBXx).
AC CONVERTER MODEL 18AC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1836 Rev.1 P. 1 / 3
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
INPUT
1
2
+
–
OUTPUT 2
POWER
OUTPUT 1
OUTPUT 2
5
6
CONNECTOR
■TERMINAL ASSIGNMENTS
12
34
78
56
18AC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1836 Rev.1 P. 2 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18BXx or 18KBXx). For the DC power source, be
sure that the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
18AC
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-1836 Rev.1 P. 3 / 3

Other M-system Media Converter manuals

M-system M8CTC User manual

M-system

M-system M8CTC User manual

M-system M8MS User manual

M-system

M-system M8MS User manual

M-system W2AP User manual

M-system

M-system W2AP User manual

M-system M8TS1 User manual

M-system

M-system M8TS1 User manual

M-system M8PT User manual

M-system

M-system M8PT User manual

M-system 17TG User manual

M-system

M-system 17TG User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system 18KTS User manual

M-system

M-system 18KTS User manual

M-system 18MS User manual

M-system

M-system 18MS User manual

M-system M8XV2 User manual

M-system

M-system M8XV2 User manual

M-system 18KRS User manual

M-system

M-system 18KRS User manual

M-system 18JV User manual

M-system

M-system 18JV User manual

M-system 10AP User manual

M-system

M-system 10AP User manual

M-system M8XV3 User manual

M-system

M-system M8XV3 User manual

M-system JAPD2 User manual

M-system

M-system JAPD2 User manual

M-system M8AP User manual

M-system

M-system M8AP User manual

M-system 18CE User manual

M-system

M-system 18CE User manual

M-system AD3V User manual

M-system

M-system AD3V User manual

M-system 15RS User manual

M-system

M-system 15RS User manual

M-system M80MS User manual

M-system

M-system M80MS User manual

M-system WRPP User manual

M-system

M-system WRPP User manual

M-system JARP2 User manual

M-system

M-system JARP2 User manual

M-system 18JM User manual

M-system

M-system 18JM User manual

M-system 18VS User manual

M-system

M-system 18VS User manual

Popular Media Converter manuals by other brands

DoorBird A1071 Series installation manual

DoorBird

DoorBird A1071 Series installation manual

Speaka Professional 1376145 operating instructions

Speaka Professional

Speaka Professional 1376145 operating instructions

Axis Q7436 installation guide

Axis

Axis Q7436 installation guide

SVSi N2211 user manual

SVSi

SVSi N2211 user manual

StarTech.com ET91000SC Specifications

StarTech.com

StarTech.com ET91000SC Specifications

Kramer VM-8H user manual

Kramer

Kramer VM-8H user manual

Lindy LDAC-Pro user guide

Lindy

Lindy LDAC-Pro user guide

moon 280D Neo Series owner's manual

moon

moon 280D Neo Series owner's manual

Yealink AVHub quick start guide

Yealink

Yealink AVHub quick start guide

StarTech.com IC485S installation manual

StarTech.com

StarTech.com IC485S installation manual

Spatz SDI-X164 Operation manual

Spatz

Spatz SDI-X164 Operation manual

Panduit Atlona OmniStream 111 installation guide

Panduit

Panduit Atlona OmniStream 111 installation guide

ECdesigns PowerDAC-R user guide

ECdesigns

ECdesigns PowerDAC-R user guide

Korg DS-DAC-100m owner's manual

Korg

Korg DS-DAC-100m owner's manual

Aurora Design SCRF User and technical manual

Aurora Design

Aurora Design SCRF User and technical manual

TP-Link MC200CM user guide

TP-Link

TP-Link MC200CM user guide

Wavetronix Click 421 Using

Wavetronix

Wavetronix Click 421 Using

Texas Instruments TMS320DM36X user guide

Texas Instruments

Texas Instruments TMS320DM36X user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.