manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Media Converter
  8. •
  9. M-system M8YV User manual

M-system M8YV User manual

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 20mA
(40mA for current output)
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
Span Adj.
Zero Adj.
Mounting Screw
Body
INSTALLATION
Use Installation Base (model: M8BSx).
SIGNAL CONVERTER MODEL M8YV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5460 Rev.2 P. 1 / 2
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
I/O PINS
17.5 (.69)
48 (1.89)
75 (2.95)
83 (3.27)
■CONNECTION DIAGRAM
+
–
Installation Base
OUTPUT 1
6
7
8
9
10
11
+
–
+
–
OUTPUT 2
1
2
A
B
POWER
+
–
INPUT
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
(Output 1 and Output 2 are linked.)
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
M8YV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5460 Rev.2 P. 2 / 2

Other M-system Media Converter manuals

M-system 17MS User manual

M-system

M-system 17MS User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system M8BS-8E1A User manual

M-system

M-system M8BS-8E1A User manual

M-system AD3V User manual

M-system

M-system AD3V User manual

M-system 18CE User manual

M-system

M-system 18CE User manual

M-system M8BS-8U1-R User manual

M-system

M-system M8BS-8U1-R User manual

M-system Mini-M M2RR User manual

M-system

M-system Mini-M M2RR User manual

M-system 18TG User manual

M-system

M-system 18TG User manual

M-system 18AC User manual

M-system

M-system 18AC User manual

M-system WRPP User manual

M-system

M-system WRPP User manual

M-system M80MS User manual

M-system

M-system M80MS User manual

M-system M8XR2 User manual

M-system

M-system M8XR2 User manual

M-system 18KVS User manual

M-system

M-system 18KVS User manual

M-system LK1 User manual

M-system

M-system LK1 User manual

M-system JAPD User manual

M-system

M-system JAPD User manual

M-system 18KJM User manual

M-system

M-system 18KJM User manual

M-system JFR2 User manual

M-system

M-system JFR2 User manual

M-system M8CTC User manual

M-system

M-system M8CTC User manual

M-system KDA3 User manual

M-system

M-system KDA3 User manual

M-system Mini-M M2AP User manual

M-system

M-system Mini-M M2AP User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system M8MS User manual

M-system

M-system M8MS User manual

M-system M8XV3 User manual

M-system

M-system M8XV3 User manual

M-system M8TS1 User manual

M-system

M-system M8TS1 User manual

Popular Media Converter manuals by other brands

Kaiser Baas KBA03026 user guide

Kaiser Baas

Kaiser Baas KBA03026 user guide

Key Digital KD-CAT5XCAT5 brochure

Key Digital

Key Digital KD-CAT5XCAT5 brochure

Pololu ROMI user guide

Pololu

Pololu ROMI user guide

WEISS Vesta owner's manual

WEISS

WEISS Vesta owner's manual

Matrix Audio element X user manual

Matrix Audio

Matrix Audio element X user manual

ADF Web HD67659-A1 user manual

ADF Web

ADF Web HD67659-A1 user manual

Xantech RF2IR2W quick start

Xantech

Xantech RF2IR2W quick start

IMC Networks IE-MiniFiberLinX-II Operation manual

IMC Networks

IMC Networks IE-MiniFiberLinX-II Operation manual

GefenTV GTV-VOLCONT-D user manual

GefenTV

GefenTV GTV-VOLCONT-D user manual

CYP CSC-6030HB Operation manual

CYP

CYP CSC-6030HB Operation manual

Pixsys 2000.35.010 user manual

Pixsys

Pixsys 2000.35.010 user manual

CONFLOW NX2-00 Installation and start-up manual

CONFLOW

CONFLOW NX2-00 Installation and start-up manual

Siemens SIMOTRAS 6SG7050 operating instructions

Siemens

Siemens SIMOTRAS 6SG7050 operating instructions

ZTC 303 manual

ZTC

ZTC 303 manual

Fermax 2430 installation guide

Fermax

Fermax 2430 installation guide

M-Audio CO2 user guide

M-Audio

M-Audio CO2 user guide

BYONICS TinyTrak3Plus owner's manual

BYONICS

BYONICS TinyTrak3Plus owner's manual

BASETech BR116 operating instructions

BASETech

BASETech BR116 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.