BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 30mA
(50mA for current output)
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within 0 to 55°C (32
to 131°F) with relative humidity within 30 to 95% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
Span Adj.
Zero Adj.
Mounting Screw
Body
INSTALLATION
Use Installation Base (model: M8BSx).
MILLIVOLT CONVERTER MODEL M8VS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5468 Rev.2 P. 1 / 2
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
I/O PINS
17.5 (.69)
48 (1.89)
75 (2.95)
83 (3.27)
■CONNECTION DIAGRAM
+
–
Installation Base
OUTPUT 1
6
7
8
9
10
11
+
–
+
–
OUTPUT 2
1
2
A
B
POWER
+
–
INPUT
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input: Check the power input voltage.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
(Output 1 and Output 2 are linked.)
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
M8VS
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-5468 Rev.2 P. 2 / 2

Other M-system Media Converter manuals

M-system M8TS1 User manual

M-system

M-system M8TS1 User manual

M-system Mini-M M2RR User manual

M-system

M-system Mini-M M2RR User manual

M-system 18TS User manual

M-system

M-system 18TS User manual

M-system M8TS User manual

M-system

M-system M8TS User manual

M-system M8PT User manual

M-system

M-system M8PT User manual

M-system 18KTS User manual

M-system

M-system 18KTS User manual

M-system M8XM2 User manual

M-system

M-system M8XM2 User manual

M-system Mini-M M2PRU User manual

M-system

M-system Mini-M M2PRU User manual

M-system M8BS-8U1-R User manual

M-system

M-system M8BS-8U1-R User manual

M-system 18PE User manual

M-system

M-system 18PE User manual

M-system M8YV1 User manual

M-system

M-system M8YV1 User manual

M-system M8BS-8E1A User manual

M-system

M-system M8BS-8E1A User manual

M-system M8CT User manual

M-system

M-system M8CT User manual

M-system M8RS1 User manual

M-system

M-system M8RS1 User manual

M-system 18KJM User manual

M-system

M-system 18KJM User manual

M-system WRPP User manual

M-system

M-system WRPP User manual

M-system AD3V User manual

M-system

M-system AD3V User manual

M-system JAPD2 User manual

M-system

M-system JAPD2 User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system M8YV User manual

M-system

M-system M8YV User manual

M-system JPR2 User manual

M-system

M-system JPR2 User manual

M-system JARP2 User manual

M-system

M-system JARP2 User manual

M-system M8XR2 User manual

M-system

M-system M8XR2 User manual

M-system 17TG User manual

M-system

M-system 17TG User manual

Popular Media Converter manuals by other brands

Yamaha DSR-100PRO Operation manual

Yamaha

Yamaha DSR-100PRO Operation manual

Konig CMP-VGACONV13 manual

Konig

Konig CMP-VGACONV13 manual

CND VS-MIDI owner's manual

CND

CND VS-MIDI owner's manual

Graham-Patten Avenue 6010 manual

Graham-Patten

Graham-Patten Avenue 6010 manual

Vision TECHCONNECT TC2-HDMIP owner's manual

Vision

Vision TECHCONNECT TC2-HDMIP owner's manual

TorTech A300 User instruction manual

TorTech

TorTech A300 User instruction manual

HSS Hire 07505 Operating & safety guide

HSS Hire

HSS Hire 07505 Operating & safety guide

Korg Polysix P6-KBD owner's manual

Korg

Korg Polysix P6-KBD owner's manual

Lindy 38296 user manual

Lindy

Lindy 38296 user manual

Hengstler ACURO AR 60 installation instructions

Hengstler

Hengstler ACURO AR 60 installation instructions

SilverStone SDP08-E manual

SilverStone

SilverStone SDP08-E manual

Scancon EXAG series installation manual

Scancon

Scancon EXAG series installation manual

Raleigh Audio Premium Extreme RAKK dac Assembly manual

Raleigh Audio

Raleigh Audio Premium Extreme RAKK dac Assembly manual

Club 3D CSV-1380 manual

Club 3D

Club 3D CSV-1380 manual

Danfoss Vacon NXP Applications manual

Danfoss

Danfoss Vacon NXP Applications manual

MIDI hardware euro-MIDECO user manual

MIDI hardware

MIDI hardware euro-MIDECO user manual

Behringer DS2800 quick start guide

Behringer

Behringer DS2800 quick start guide

Comtech EF Data UT-4518E-1 Installation and operation manual

Comtech EF Data

Comtech EF Data UT-4518E-1 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.